摘要
The field data from an integrated CO2 refrigeration system installed in a supermarket located north of the capital of Lisbon was analyzed. The goal was to demonstrate the effect and performance of multi-ejectors on a refrigeration system operating in a warm climate. The measurement results for the system with and without activating ejectors were compared. It was observed that the system with a multi-ejector operation had considerable performance superiority. The ejectors improved the cooling capacity of the medium temperature stage of the system by 17.4%. The system with active ejectors had 7.5% less total power consumption compared to the ejector off mode of the same system.
引用
收藏
页数:16
相关论文
共 26 条
[1]  
Banasiak K., 2018, P 13 IIR GUST LOR C
[2]   Influence of operating conditions on the temperature performance of a closed refrigerated display cabinet [J].
Chaomuang, Nattawut ;
Flick, Denis ;
Denis, Alain ;
Laguerre, Onrawee .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 103 :32-41
[3]  
Cooling A.-A.C., 2020, FOOD RETAIL BEST PRA
[4]   Preliminary study on the feasibility assessment of CO2 booster refrigeration systems for supermarket application in China: An energetic, economic, and environmental analysis [J].
Cui, Qi ;
Gao, Enyuan ;
Zhang, Zhiyuan ;
Zhang, Xiaosong .
ENERGY CONVERSION AND MANAGEMENT, 2020, 225 (225)
[5]   R744 booster integrated system for full heating supply to supermarkets [J].
D'Agaro, Paola ;
Cortella, Giovanni ;
Polzot, Alessio .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 96 :191-200
[6]   Effect of door opening frequency and duration of an enclosed refrigerated display case on product temperatures and energy consumption [J].
de Frias, J. Atilio ;
Luo, Yaguang ;
Zhou, Bin ;
Zhang, Boce ;
Ingram, David T. ;
Vorst, Keith ;
Brecht, Jeffrey K. ;
Stommel, John .
FOOD CONTROL, 2020, 111
[7]   Transcritical R744 refrigeration systems for supermarket applications: Current status and future perspectives [J].
Gullo, Paride ;
Hafner, Armin ;
Banasiak, Krzysztof .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2018, 93 :269-310
[8]   State-of-the-art technologies for transcritical R744 refrigeration systems - a theoretical assessment of energy advantages for European food retail industry [J].
Gullo, Paride ;
Tsamos, Konstantinos ;
Hafner, Armin ;
Ge, Yunting ;
Tassou, Savvas A. .
PROCEEDINGS OF 1ST INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS (ICFES 2017), INCLUDING SYMPOSIUM ON HEAT RECOVERY AND EFFICIENT CONVERSION AND UTILISATION OF WASTE HEAT, 2017, 123 :46-53
[9]   Multi-ejector R744 booster refrigerating plant and air conditioning system integration-A theoretical evaluation of energy benefits for supermarket applications [J].
Gullo, Paride ;
Hafner, Armin ;
Cortella, Giovanni .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 75 :164-176
[10]   Multi-ejector concept for R-744 supermarket refrigeration [J].
Hafner, Armin ;
Foersterling, Sven ;
Banasiak, Krzysztof .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 43 :1-13