Reproducibility of the study of placental vascularization by three-dimensional power Doppler

被引:101
作者
Mercé, LT
Barco, MJ
Bau, S
机构
[1] Int Ruber Hosp, Dept Obstet & Gynecol, Madrid, Spain
[2] Univ Cli Lozano Blesa, Dept Obstet & Gynecol, Zaragoza, Spain
关键词
placental vascularization; three-dimensional ultrasound; three-dimensional power Doppler;
D O I
10.1515/JPM.2004.043
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aims: To assess the reproducibility of 3D power Doppler study of placental vascularization in order to establish its methodological bases for its further application in normal and pathological pregnancies. Methods: A prospective study was carried on 30 normal singleton pregnancies from 14 to 40 weeks. To evaluate placental vascularization 3D power Doppler was applied to obtain a "placental biopsy". The spherical volume acquired was analyzed using the VOCAL imaging program. Two consecutive measurements were taken from each patient by a single observer, obtaining a total of 60 datasets. Placental volume (PV), Mean Gray (MG), Vascularization Index (VI), Flow Index (FI) and Vascularization Flow Index (VFI) were calculated. Intra-class correlation coefficient (ICC) and intra-observer agreement was evaluated. Results: PV and MG presented an ICC of 0.98 and 0.94 respectively, with differences approaching zero. All 3D power Doppler vascular indices (VI, FI and VFI) showed a correlation greater than 0.85, with a better intra-observer agreement for the flow indices (FI and VFI). Conclusions: Placental vascular biopsy through 3D power Doppler is a new and simple tool to routinely study placental vascularization in human pregnancy. Our results provide the validation of the technique demonstrating a good reproducibility of the 3D power Doppler parameters when applied to the study of the placental vascular tree in normal pregnancies.
引用
收藏
页码:228 / 233
页数:6
相关论文
共 35 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Reproducibility of transvaginal three-dimensional endometrial volume measurements with virtual organ computer-aided analysis (VOCAL) during ovarian stimulation [J].
Bordes, A ;
Bory, AM ;
Benchaïb, M ;
Rudigoz, RC ;
Salle, B .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 19 (01) :76-80
[3]  
CAVERO A, 1993, THESIS U NAVARRA
[4]  
Dolz M, 1999, J ULTRAS MED, V18, P303
[5]   Is three-dimensional power Doppler ultrasound better than two-dimensional power Doppler? Reply [J].
Fishman, DA ;
Cohen, L .
GYNECOLOGIC ONCOLOGY, 2002, 84 (02) :353-353
[6]  
FOK RY, 1990, OBSTET GYNECOL, V75, P578
[7]   FETAL UMBILICAL ARTERY FLOW VELOCITY WAVEFORMS AND PLACENTAL RESISTANCE - PATHOLOGICAL CORRELATION [J].
GILES, WB ;
TRUDINGER, BJ ;
BAIRD, PJ .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (01) :31-38
[8]   ESTIMATION OF FETAL WEIGHT WITH THE USE OF HEAD, BODY, AND FEMUR MEASUREMENTS - A PROSPECTIVE-STUDY [J].
HADLOCK, FP ;
HARRIST, RB ;
SHARMAN, RS ;
DETER, RL ;
PARK, SK .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 151 (03) :333-337
[9]   Assessment of early chorionic circulation by three-dimensional power Doppler [J].
Hafner, T ;
Kurjak, A ;
Funduk-Kurjak, B ;
Bekavac, I .
JOURNAL OF PERINATAL MEDICINE, 2002, 30 (01) :33-39
[10]   Doppler velocimetry of intraplacental fetal vessels in the second trimester: Improving the prediction of pregnancy complications in high-risk patients [J].
Jaffe, R ;
Woods, JR .