Development of an Infrared Monitor-Guided Bleb Revision Procedure

被引:2
作者
Matsushita, Kenji [1 ]
Kawashima, Rumi [1 ]
Nishida, Kohji [1 ]
机构
[1] Osaka Univ, Dept Ophthalmol, Grad Sch Med, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
关键词
Trabeculectomy; Bleb revision; Bleb knife; Infrared light; 5-fluorouracil; NEEDLE REVISION;
D O I
10.1159/000508606
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The needle revision procedure to address failing filtering blebs is a blind technique that might easily damage the scleral flap, conjunctiva, and choroid. We propose a new surgical procedure, infrared monitor-guided bleb revision, to perform bleb revision minimally invasively and effectively, and demonstrate the procedure in a patient. We developed the guided procedure with the infrared monitor to observe the bleb interior with greater contrast. Under the monitor, we dissect the hard fibrotic tissue with a bleb knife and, if necessary, remove adhesions using a needle and vitreous forceps. Finally, 5-fluorouracil is injected into the subconjunctiva. We have performed bleb revisions safely with clear visualization of the scleral flap using an infrared light. In the current case, the patient had good intraocular pressure control for about 1 year. The new infrared monitor-guided bleb revision procedure facilitates successful bleb revisions without damage to the underlying structures.
引用
收藏
页码:234 / 241
页数:8
相关论文
共 10 条
[1]   Needle revision of failing and failed trabeculectomy blebs with adjunctive 5-fluorouracil survival analysis [J].
Broadway, DC ;
Bloom, PA ;
Bunce, C ;
Thiagarajan, M ;
Khaw, PT .
OPHTHALMOLOGY, 2004, 111 (04) :665-673
[2]   Needle Revision of Filtering Blebs [J].
Feldman, Robert M. ;
Tabet, Rania R. .
JOURNAL OF GLAUCOMA, 2008, 17 (07) :594-600
[3]  
Ferrer H., 1941, Am J Ophthalmol, V24, P788
[4]   Bleb Analysis by Using Anterior Segment Optical Coherence Tomography in Two Different Methods of Trabeculectomy [J].
Hamanaka, Teruhiko ;
Omata, Takayasu ;
Sekimoto, Shinichiro ;
Sugiyama, Takakazu ;
Fujikoshi, Yasunori .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) :6536-6541
[5]  
Nomura H, 2011, J EYE, V28, P879
[6]  
Sagara T, 2010, J OPHTHALMIC SURG, V23, P71
[7]   Slit-lamp needle revision of failed filtering blebs using high-dose mitomycin C [J].
Shetty, RK ;
Wartluft, L ;
Moster, MR .
JOURNAL OF GLAUCOMA, 2005, 14 (01) :52-56
[8]   Meibomian Gland Morphology in Japanese Infants, Children, and Adults Observed Using a Mobile Pen-shaped Infrared Meibography Device [J].
Shirakawa, Rika ;
Arita, Reiko ;
Amano, Shiro .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (06) :1099-1103
[9]   Prospective 3D Investigation of Bleb Wall after Trabeculectomy Using Anterior-Segment OCT [J].
Watanabe-Kitamura, Fumika ;
Inoue, Toshihiro ;
Kojima, Sachi ;
Nakashima, Kei-Ichi ;
Fukushima, Ayako ;
Tanihara, Hidenobu .
JOURNAL OF OPHTHALMOLOGY, 2017, 2017
[10]   The 5-Year Incidence of Bleb-Related Infection and Its Risk Factors after Filtering Surgeries with Adjunctive Mitomycin C Collaborative Bleb-Related Infection Incidence and Treatment Study 2 [J].
Yamamoto, Tetsuya ;
Sawada, Akira ;
Mayama, Chihiro ;
Araie, Makoto ;
Ohkubo, Shinji ;
Sugiyama, Kazuhisa ;
Kuwayama, Yasuaki .
OPHTHALMOLOGY, 2014, 121 (05) :1001-1006