Simultaneous dual-isotope solid-state detector SPECT for improved tracking of white blood cells in suspected endocarditis

被引:44
作者
Caobelli, Federico [1 ]
Wollenweber, Tim [1 ]
Bavendiek, Udo [2 ]
Kuehn, Christian [3 ]
Schuetze, Christian [4 ]
Geworski, Lilli [4 ]
Thackeray, James T. [1 ]
Bauersachs, Johann [2 ]
Haverich, Axel [3 ]
Bengel, Frank M. [1 ]
机构
[1] Hannover Med Sch, Dept Nucl Med, Hannover, Germany
[2] Hannover Med Sch, Dept Cardiol & Angiol, Hannover, Germany
[3] Hannover Med Sch, Dept Cardiothorac Transplantat & Vasc Surg, Hannover, Germany
[4] Hannover Med Sch, Dept Radiat Protect & Med Phys, Hannover, Germany
关键词
Endocarditis; White blood cell tracking; Solid-state detector imaging; Single-photon emission computed tomography; MYOCARDIAL-PERFUSION SPECT; ATTENUATION CORRECTION; DUKE CRITERIA; STEM-CELLS; DIAGNOSIS; SCINTIGRAPHY; PERFORMANCE; LIMITATIONS; CAMERA; PET;
D O I
10.1093/eurheartj/ehw231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims High-energy resolution and sensitivity of novel cadmium-zinc-telluride (CZT) detector equipped SPECT systems facilitate simultaneous imaging of multiple isotopes and may enhance the detection of molecular/cellular signals. This may refine the detection of endocarditis. This study was designed to determine the feasibility and diagnostic accuracy of simultaneous imaging of inflammation with In-111-labeled white blood cells (WBCs) and myocardial perfusion with Tc-99m-sestamibi, for localization of WBCs relative to the valve plane in suspected endocarditis. Methods and results A dedicated cardiac CZT camera (Discovery 530c, GE Healthcare) was employed. Anthropomorphic thorax phantom studies were followed by clinical studies in 34 patients with suspected infection of native valves (n = 12) or implants (n = 22). Simultaneous In-111-WBC/(99)mTc perfusion imaging was performed, and compared with standard In-111-WBC planar scintigraphy and SPECT-CT. Phantom studies ruled out significant radioisotope crosstalk. Downscatter on Tc-99m images was not observed for In-111 activity as high as 2.5*Tc-99m activity. In patients, image quality was superior for CZT imaging vs. conventional SPECT-CT and planar scintigraphy (P < 0.01). Cadmium-zinc-telluride dual isotope imaging improved reader confidence for detection of inflammatory foci. Diagnostic accuracy based on surgery or Duke Criteria during follow-up was highest for CZT imaging (P < 0.001). Conclusion Novel CZT SPECT technology improves the accuracy of molecular/cellular cardiac imaging. Simultaneous multi-isotope imaging with In-111 and Tc-99m is feasible and aids in the workup of suspected endocarditis.
引用
收藏
页码:436 / 443
页数:8
相关论文
共 26 条
[1]   Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera [J].
Ben-Haim, Simona ;
Kacperski, Krzysztof ;
Hain, Sharon ;
Van Gramberg, Dean ;
Hutton, Brian F. ;
Erlandsson, Kjell ;
Sharir, Tali ;
Roth, Nathaniel ;
Waddington, Wendy A. ;
Berman, Daniel S. ;
Ell, Peter J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) :1710-1721
[2]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[3]   Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation [J].
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Treyer, Valerie ;
Valenta, Ines ;
von Schulthess, Patrick ;
Nkoulou, Rene ;
Wyss, Christophe A. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) :773-778
[4]  
Caveliers V, 2007, Q J NUCL MED MOL IM, V51, P61
[5]  
CERQUEIRA MD, 1989, J NUCL MED, V30, P703
[6]   Quantitative simultaneous 111In/99mTc SPECT-CT of osteomyelitis [J].
Cervo, Morgan ;
Gerbaudo, Victor H. ;
Park, Mi-Ae ;
Moore, Stephen C. .
MEDICAL PHYSICS, 2013, 40 (08)
[7]   Comparison of Image Quality, Myocardial Perfusion, and Left Ventricular Function Between Standard Imaging and Single-Injection Ultra-Low-Dose Imaging Using a High-Efficiency SPECT Camera: The MILLISIEVERT Study [J].
Einstein, Andrew J. ;
Blankstein, Ron ;
Andrews, Howard ;
Fish, Mathews ;
Padgett, Richard ;
Hayes, Sean W. ;
Friedman, John D. ;
Qureshi, Mehreen ;
Rakotoarivelo, Harivony ;
Slomka, Piotr ;
Nakazato, Ryo ;
Bokhari, Sabahat ;
Di Carli, Marcello ;
Berman, Daniel S. .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (09) :1430-1437
[8]   Radiolabeled WBC Scintigraphy in the Diagnostic Workup of Patients With Suspected Device-Related Infections [J].
Erba, Paola A. ;
Sollini, Martina ;
Conti, Umberto ;
Bandera, Francesco ;
Tascini, Carlo ;
De Tommasi, Salvatore M. ;
Zucchelli, Giulio ;
Doria, Roberta ;
Menichetti, Francesco ;
Bongiorni, Maria Grazia ;
Lazzeri, Elena ;
Mariani, Giuliano .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (10) :1075-1086
[9]   Echocardiography in infective endocarditis [J].
Evangelista, A ;
González-Alujas, MT .
HEART, 2004, 90 (06) :614-617
[10]   Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration [J].
Goetze, Sibyll ;
Brown, Tracy L. ;
Lavely, William C. ;
Zhang, Zhe ;
Bengel, Frank M. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) :1090-1095