Diagnostic performance for erosion detection in sacroiliac joints on MR T1-weighted images: Comparison between different slice thicknesses

被引:11
作者
Chen, Min [1 ]
Herregods, Nele [1 ]
Jaremko, Jacob L. [2 ]
Carron, Philippe [3 ,4 ]
Elewaut, Dirk [3 ,4 ]
Van den Bosch, Filip [3 ,4 ]
Jans, Lennart [1 ]
机构
[1] Ghent Univ Hosp, Dept Radiol, Corneel Heymanslaan 10, B-9000 Ghent, Belgium
[2] Univ Alberta Hosp, Dept Radiol & Diagnost Imaging, 8440-112 St, Edmonton, AB T6G 2B7, Canada
[3] Ghent Univ Hosp, Dept Rheumatol, Corneel Heymanslaan 10, B-9000 Ghent, Belgium
[4] Ghent Univ VIB, Inflammat Res Ctr, Unit Mol Immunol & Inflammat, Technol Pk 927, B-9052 Ghent, Belgium
关键词
Slice thickness; Magnetic resonance imaging; Spondyloarthritis; Erosion; COMPUTED-TOMOGRAPHY; STRUCTURAL LESIONS; SPONDYLOARTHRITIS; RADIOGRAPHS; FEATURES; CT;
D O I
10.1016/j.ejrad.2020.109352
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the effect of slice thickness on the diagnostic accuracy of erosion detection at MR T1-weighted images (T1WI) of the sacroiliac joints (SIJ) in adult patients suspected of sacroiliitis. Method: Patients aged 18-60 years with clinical suspicion of sacroiliitis were enrolled. All patients underwent CT and 3 T MRI of the SIJs on the same day. CT at 1 mm slice thickness, semi-coronal spin echo T1WI sequences with four different slice thicknesses (2, 3, 4 and 5 mm) were obtained. For scoring erosions, each SIJ was divided into four quadrants. Presence or absence of erosions was scored on T1WI sequences by two independent readers blinded to other data. Inter-reader agreement was assessed using kappa statistics. Diagnostic accuracy of MRI for erosions at each slice thickness was evaluated vs. consensus CT as reference standard, using area under the receiver operating characteristic curve (AUC). Results: Fifty-three patients (23 men, 30 women, mean age, 39.0 years +/- 10.2) were included. Inter-reader agreement for erosion score on all T1WI sequences was moderate (kappa value 0.54 to 0.60). With increasing slice thickness, both the recorded total number of erosions and sensitivity for erosion vs. CT decreased. The AUC were significantly higher for 2 mm and 3 mm T1WI than for 4 mm and 5 mm T1WI. Conclusions: The diagnostic accuracy of T1WI for erosion detection vs. a CT reference standard is affected by slice thickness. Thinner slices (2 or 3 mm) had significantly higher diagnostic accuracy than thicker slices (4 or 5 mm).
引用
收藏
页数:8
相关论文
共 33 条
  • [1] Can we use structural lesions seen on MRI of the sacroiliac joints reliably for the classification of patients according to the ASAS axial spondyloarthritis criteria? Data from the DESIR cohort
    Bakker, Pauline A. C.
    van den Berg, Rosaline
    Lenczner, Gregory
    Thevenin, Fabrice
    Reijnierse, Monique
    Claudepierre, Pascal
    Wendling, Daniel
    Dougados, Maxime
    van der Heijde, Desiree
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 (02) : 392 - 398
  • [2] Detection of Erosions in Sacroiliac Joints of Patients with Axial Spondyloarthritis Using the Magnetic Resonance Imaging Volumetric Interpolated Breath-hold Examination
    Baraliakos, Xenofon
    Hoffmann, Florian
    Deng, Xiaohu
    Wang, Yan-Yan
    Huang, Feng
    Braun, Juergen
    [J]. JOURNAL OF RHEUMATOLOGY, 2019, 46 (11) : 1445 - 1449
  • [3] Adjusting for multiple testing - when and how?
    Bender, R
    Lange, S
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2001, 54 (04) : 343 - 349
  • [4] Improved detection of erosions in the sacroiliac joints on MRI with volumetric interpolated breath-hold examination (VIBE): results from the SIMACT study
    Diekhoff, Torsten
    Greese, Juliane
    Sieper, Joachim
    Poddubnyy, Denis
    Hamm, Bernd
    Hermann, Kay-Geert A.
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2018, 77 (11) : 1585 - 1589
  • [5] Comparison of MRI with radiography for detecting structural lesions of the sacroiliac joint using CT as standard of reference: results from the SIMACT study
    Diekhoff, Torsten
    Hermann, Kay-Geert A.
    Greese, Juliane
    Schwenke, Carsten
    Poddubnyy, Denis
    Hamm, Bernd
    Sieper, Joachim
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 (09) : 1502 - 1508
  • [6] Does diffusion-weighted imaging add diagnostic confidence in discriminating between benign and malignant solid focal liver lesions?
    Girometti, Rossano
    Del Pin, Matteo
    Pullini, Serena
    Cereser, Lorenzo
    Como, Giuseppe
    Bazzocchi, Massimo
    Zuiani, Chiara
    [J]. CLINICAL IMAGING, 2014, 38 (02) : 136 - 141
  • [7] Bias and prevalence effects on kappa viewed in terms of sensitivity and specificity
    Hoehler, FK
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2000, 53 (05) : 499 - 503
  • [8] The performance of MRI in detecting subarticular bone erosion of sacroiliac joint in patients with spondyloarthropathy: A comparison with X-ray and CT
    Hu, Libin
    Huang, Zhenguo
    Zhang, Xuezhe
    Chan, Queenie
    Xu, Yanyan
    Wang, Guochun
    Wang, Wu
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (11) : 2058 - 2064
  • [9] HOW SENSITIVE AND SPECIFIC ARE MRI FEATURES OF SACROILIITIS FOR DIAGNOSIS OF SPONDYLOARTHRITIS IN PATIENTS WITH INFLAMMATORY BACK PAIN?
    Jans, L.
    Coeman, L.
    Van Praet, L.
    Carron, P.
    Elewaut, D.
    Van den Bosch, F.
    Jaremko, J. L.
    Huysse, W.
    Verstraete, K. L.
    [J]. JBR-BTR, 2014, 97 (04): : 202 - 205
  • [10] Erosions and Fatty Lesions of Sacroiliac Joints in Patients with Axial Spondyloarthritis: Evaluation of Different MRI Techniques and Two Scoring Methods
    Krohn, Michaela
    Braum, Leonie S.
    Sieper, Joachim
    Song, In-Ho
    Weiss, Anja
    Callhoff, Johanna
    Althoff, Christian E.
    Hamm, Bernd
    Hermann, Kay-Geert A.
    [J]. JOURNAL OF RHEUMATOLOGY, 2014, 41 (03) : 473 - 480