Thermal influence of radiofrequency ablation for bone: an experimental study in normal rabbit bone

被引:9
|
作者
Yamamoto, Shuichi [1 ]
Kaminou, Toshio [1 ]
Ono, Yuichi [2 ]
Hashimoto, Masayuki [3 ]
Ohuchi, Yasufumi [4 ]
Yoshida, Haruhiko [5 ]
Ogawa, Toshihide [1 ]
机构
[1] Tottori Univ, Fac Med, Div Radiol, Dept Pathophysiol & Therapeut Sci, Yonago, Tottori 6838504, Japan
[2] Tottori Univ, Grad Sch Engn, Dept Mech & Aerosp Engn, Tottori 6808552, Japan
[3] Tottori Prefectural Kosei Hosp, Dept Radiol, Kurayoshi, Tottori 6820804, Japan
[4] San In Rosai Hosp, Dept Radiol, Yonago, Tottori 6830002, Japan
[5] Natl Hosp Org Yonago Med Ctr, Clin Examinat Dept, Yonago, Tottori 6830006, Japan
关键词
Radiofrequency ablation; Bone; Strength; METASTASES INVOLVING BONE; OSTEOID OSTEOMA; TISSUE ABLATION; TRABECULAR BONE; ELECTRODE; STRENGTH; RECONSTRUCTION; PARAMETERS; EXPERIENCE; THERAPY;
D O I
10.1007/s00256-013-1807-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To evaluate the heat effects of radiofrequency ablation (RFA) on normal bone by mechanical testing, MRI, and histology. The institutional animal care and use committee approved the animal study. Thirty-two adult Japanese white rabbits were included in our study. Bone biopsy needles were inserted from the distal end of the right (RFA side) and the left (control side) femurs using a fluoroscopic guide. A 17-gauge internally cooled RFA electrode with a 2-cm active tip was inserted through the needle to the right femur, and RFA was performed for 12 min using a 200-W generator. Animals were divided into four groups and 8 animals from each group were euthanized on day 1, day 7, day 30, and day 60 after RFA. MRI was performed prior to euthanasia. Three-point bending test was performed to measure flexural strength. Student's t test was used to evaluate for significant differences between RFA and control side for each group. Femurs underwent histological examination by hematoxylin and eosin staining after the bending test. MRI showed a high-intensity rim around the bone on T2WI. Three-point bending test showed no statistically significant differences (P < 0.05) between the RFA and the control side in any of the groups. Histologically, osteocytes of cortical bone showed cell death, but the lamellar structure was preserved in all groups and bone remodeling was observed. Heat by RFA did not change normal bone strength within 2 months, despite the heat effects in the cortical bone and cell death.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 50 条
  • [41] Support adapter for radiofrequency ablation probe: Experimental study
    Ishikawa, S
    Oki, S
    Muraoka, M
    Kashiwabara, K
    Morishita, Y
    ANZ JOURNAL OF SURGERY, 2005, 75 (03) : 157 - 159
  • [42] Transvenous Radiofrequency Ablation of Adrenal Gland: Experimental Study
    Sakakibara, Hiroyuki
    Seiji, Kazumasa
    Oguro, Sota
    Mori, Kenji
    Omata, Kei
    Tezuka, Yuta
    Ono, Yoshikiyo
    Morimoto, Ryo
    Masuda, Takuya
    Miyamoto, Hisao
    Hirao, Takuya
    Niwa, Yuki
    Suzuki, Yohei
    Baba, Yasutaka
    Satoh, Fumitoshi
    Takase, Kei
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (08) : 1178 - 1185
  • [43] CIRSE Standards of Practice on Thermal Ablation of Bone Tumours
    Anthony Ryan
    Caoimhe Byrne
    Claudio Pusceddu
    Xavier Buy
    Georgia Tsoumakidou
    Dimitrios Filippiadis
    CardioVascular and Interventional Radiology, 2022, 45 : 591 - 605
  • [44] Numerical study of the influence of water evaporation on radiofrequency ablation
    Qing Zhu
    Yuanyuan Shen
    Aili Zhang
    Lisa X Xu
    BioMedical Engineering OnLine, 12
  • [45] Double Slot Antenna for Microwave Thermal Ablation to Treat Bone Tumors: Modeling and Experimental Evaluation
    Trujillo-Romero, Citlalli Jessica
    Leija-Salas, Lorenzo
    Vera-Hernandez, Arturo
    Rico-Martinez, Genaro
    Gutierrez-Martinez, Josefina
    ELECTRONICS, 2021, 10 (07)
  • [46] Numerical study of the influence of water evaporation on radiofrequency ablation
    Zhu, Qing
    Shen, Yuanyuan
    Zhang, Aili
    Xu, Lisa X.
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [47] Influence of bone microstructure on the mechanical properties of skull cortical bone - A combined experimental and computational approach
    Boruah, Sourabh
    Subit, Damien L.
    Paskoff, Glenn R.
    Shender, Barry S.
    Crandall, Jeff R.
    Salzar, Robert S.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 : 688 - 704
  • [48] Thermal Ablation of Lung Tissue: In Vivo Experimental Comparison of Microwave and Radiofrequency
    Laura Crocetti
    Elena Bozzi
    Pinuccia Faviana
    Dania Cioni
    Clotilde Della Pina
    Alberto Sbrana
    Gabriella Fontanini
    Riccardo Lencioni
    CardioVascular and Interventional Radiology, 2010, 33 : 818 - 827
  • [49] Setup of a bone aging experimental model in the rabbit comparing changes in cortical and trabecular bone: Morphological and morphometric study in the femur
    Pazzaglia, Ugo E.
    Sibilia, Valeria
    Congiu, Terenzio
    Pagani, Francesca
    Ravanelli, Marco
    Zarattini, Guido
    JOURNAL OF MORPHOLOGY, 2015, 276 (07) : 733 - 747
  • [50] Radiofrequency ablation therapy for bone metastasis from hepatocellular carcinoma: Case report
    Maruyama, M
    Asano, T
    Kenmochi, T
    Kainuma, O
    Iwasaki, K
    Miyauchi, H
    Saigo, K
    Miura, F
    Kobayashi, S
    Ochiai, T
    ANTICANCER RESEARCH, 2003, 23 (3C) : 2987 - 2989