Stability of Acylcarnitines and Free Carnitine in Dried Blood Samples: Implications for Retrospective Diagnosis of Inborn Errors of Metabolism and Neonatal Screening for Carnitine Transporter Deficiency

被引:59
作者
Fingerhut, Ralph [1 ]
Ensenauer, Regina [2 ]
Roechinger, Wulf [2 ]
Arnecke, Ralf [1 ]
Olgemoeller, Bernhard [1 ]
Roscher, Adelbert A. [2 ]
机构
[1] Olgemoller & Coll, Lab Becker, Munich, Germany
[2] Univ Munich, Res Ctr, Dept Biochem Genet & Mol Biol, Dr von Hauner Childrens Hosp, Munich, Germany
关键词
TANDEM MASS-SPECTROMETRY; SPOTS; SPECIMENS; MUTATIONS; DEATH;
D O I
10.1021/ac8022235
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Objective: Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) is increasingly used in newborn screening programs. Acylcarnitine profiles from dried blood spots (DBS) are used to detect fatty acid oxidation disorders, carnitine cycle disorders, and organic acidurias. Stored dried blood is also a valuable source for postmortem investigations to unravel the cause of unexplained death in early childhood. However, diagnostic uncertainties arising from the unknown stability of acylcarnitines and free carnitine during prolonged storage have not yet been studied in a systematic manner. Methods: Whole blood spiked with acylcarnitines was stored either at -18 degrees C or at room temperature up to 1000 days. At regular time intervals, 3.2 mm spots of these samples were extracted with 150 mu L of methanol. Free carnitine and acylcarnitines were converted to their corresponding butyl esters and analyzed by ESI-MS/MS. Results: At -18 degrees C acylcarnitines are stable for at least 330 days. If stored for prolonged periods at room temperature (> 14 days), acylcarnitines are hydrolyzed to free carnitine and the corresponding fatty acids. The velocity of decay is logarithmic and depends on the chain length of the acylcarnitines. Short-chain acylcarnitines hydrolyze quicker than long-chain acylcarnitines. Conclusion: The data indicate that stored filter cards should only be used for retrospective quantitation of acylcarnitines if appropriate correction for sample decay during storage is applied. Free carnitine increases upon storage but can reliably be quantitated under standardized detivatization conditions. Furthermore, carnitine transporter (OCTN2) deficiency can reliably be diagnosed by examining acylcarnitine profiles, which can supplement free carnitine levels as a discriminatory marker.
引用
收藏
页码:3571 / 3575
页数:5
相关论文
共 16 条
[1]   CARNITINE IN DRIED BLOOD SPOTS - A METHOD SUITABLE FOR NEONATAL SCREENING [J].
BARNS, RJ ;
BOWLING, FG ;
BROWN, G ;
CLAGUE, AE ;
THOMPSON, A .
CLINICA CHIMICA ACTA, 1991, 197 (01) :27-34
[2]   Use of tandem mass spectrometry for multianalyte screening of dried blood specimens from newborns [J].
Chace, DH ;
Kalas, TA ;
Naylor, EW .
CLINICAL CHEMISTRY, 2003, 49 (11) :1797-1817
[3]  
Chace DH, 2001, CLIN CHEM, V47, P1166
[4]  
Christensen E., 2000, Journal of Inherited Metabolic Disease, V23, P117
[5]  
Fingerhut R, 2001, CLIN CHEM, V47, P1763
[6]   Inaccurate measurement of free carnitine by the electrospray tandem mass spectrometry screening method for blood spots [J].
Johnson, DW .
JOURNAL OF INHERITED METABOLIC DISEASE, 1999, 22 (02) :201-202
[7]   Stability of malonylcarnitine and glutarylcarnitine in stored blood spots [J].
Johnson, DW ;
Trinh, MU .
JOURNAL OF INHERITED METABOLIC DISEASE, 2004, 27 (06) :789-790
[8]   Novel OCTN2 mutations:: No genotype-phenotype correlations:: Early carnitine therapy prevents cardiomyopathy [J].
Lamhonwah, AM ;
Olpin, SE ;
Pollitt, RJ ;
Vianey-Saban, C ;
Divry, P ;
Guffon, N ;
Besley, GTN ;
Onizuka, R ;
De Meirleir, LJ ;
Cvitanovic-Sojat, L ;
Baric, I ;
Dionisi-Vici, C ;
Fumic, K ;
Maradin, M ;
Tein, I .
AMERICAN JOURNAL OF MEDICAL GENETICS, 2002, 111 (03) :271-284
[9]  
LEVITAN MD, 1987, CAN J NEUROL SCI, V14, P50
[10]   Sudden neonatal death in carnitine transporter deficiency [J].
Rinaldo, P ;
Stanley, CA ;
Hsu, BYL ;
Sanchez, LA ;
Stern, HJ .
JOURNAL OF PEDIATRICS, 1997, 131 (02) :304-305