Community-scale residential air conditioning control for effective grid management

被引:57
作者
Cole, Wesley J. [1 ]
Rhodes, Joshua D. [2 ]
Gorman, William [1 ]
Perez, Krystian X. [1 ]
Webber, Michael E. [3 ,4 ]
Edgar, Thomas F. [1 ,4 ]
机构
[1] Univ Texas Austin, McKetta Dept Chem Engn, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
[3] Univ Texas Austin, Dept Mech Engn, Austin, TX 78712 USA
[4] Univ Texas Austin, Energy Inst, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
Model predictive control; Precooling; Community energy management; Peak demand; Thermal energy storage; Residential air conditioning; THERMOSTATICALLY CONTROLLED LOADS; DEMAND RESPONSE; THERMAL STORAGE; POWER DEMAND; POPULATIONS; PERFORMANCE; STRATEGIES; BUILDINGS; SERVICE; SYSTEM;
D O I
10.1016/j.apenergy.2014.05.067
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper investigates the potential for coordinated control of a large number of residential air conditioning systems to achieve substantial reductions in peak electricity demand. To do so, an extensive data set including home energy audits, homeowner surveys, and electricity meter measurements from homes in Austin, Texas, USA, was used to build a simulated community of 900 homes. Based on a reduced-order modeling strategy and an economic model predictive control approach, we analyze the effects of the community of homes responding optimally to variations in wholesale market electricity prices. We find that when exposed to dynamic pricing, peak demand from residential electricity consumption is shifted to earlier in the day, and is lower than the peak where no intervention is made. We also consider centralized and decentralized strategies for minimizing the peak demand of the community. For this simulated community, we find that centralized, coordinated control of residential air conditioning systems reduces overall peak by 8.8% but increases total energy consumption by 133%. Decentralized control reduces overall peak by 5.7%, demonstrating that the value of information sharing for peak reduction is 3.1%. It is also shown that properly tuned penalty terms allow a penalty-based decentralized controller to approach the optimal solution obtained by a centralized controller without the requirement of information sharing. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:428 / 436
页数:9
相关论文
共 32 条
[1]  
[Anonymous], 2011, AMIT DSWG WORKSH AMI
[2]  
[Anonymous], 105 CSEM WP U CAL EN
[3]   State of the art of thermal storage for demand-side management [J].
Arteconi, A. ;
Hewitt, N. J. ;
Polonara, F. .
APPLIED ENERGY, 2012, 93 :371-389
[4]   Introducing a demand-based electricity distribution tariff in the residential sector: Demand response and customer perception [J].
Bartusch, Cajsa ;
Wallin, Fredrik ;
Odlare, Monica ;
Vassileva, Iana ;
Wester, Lars .
ENERGY POLICY, 2011, 39 (09) :5008-5025
[5]   Modeling and Control of Aggregate Air Conditioning Loads for Robust Renewable Power Management [J].
Bashash, Saeid ;
Fathy, Hosam K. .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2013, 21 (04) :1318-1327
[6]   Incorporating residential AC load control into ancillary service markets: Measurement and settlement [J].
Bode, Josh L. ;
Sullivan, Michael J. ;
Berghman, Dries ;
Eto, Joseph H. .
ENERGY POLICY, 2013, 56 :175-185
[7]   Modeling framework and validation of a smart grid and demand response system for wind power integration [J].
Broeer, Torsten ;
Fuller, Jason ;
Tuffner, Francis ;
Chassin, David ;
Djilali, Ned .
APPLIED ENERGY, 2014, 113 :199-207
[8]   Achieving Controllability of Electric Loads [J].
Callaway, Duncan S. ;
Hiskens, Ian A. .
PROCEEDINGS OF THE IEEE, 2011, 99 (01) :184-199
[9]   Tapping the energy storage potential in electric loads to deliver load following and regulation, with application to wind energy [J].
Callaway, Duncan S. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (05) :1389-1400
[10]   Effect of adjacent shading on the thermal performance of residential buildings in a subtropical region [J].
Chan, A. L. S. .
APPLIED ENERGY, 2012, 92 :516-522