Airway management in prehospital emergency medicine

被引:1
作者
Piepho, T. [1 ]
机构
[1] Krankenhaus Barmherzigen Bruder, Abt Anasthesie & Intens Med, Nordallee 1, D-54292 Trier, Germany
来源
ANASTHESIOLOGIE & INTENSIVMEDIZIN | 2020年 / 61卷
关键词
Airway Management; Intubation; Video Laryngoscopy; Extraglottic Airway; Cricothyrotomy; CRITICALLY-ILL PATIENTS; BAG-VALVE-MASK; LARYNGEAL MASK; TRACHEAL INTUBATION; VIDEO LARYNGOSCOPE; CERVICAL-SPINE; CARDIAC-ARREST; GLIDESCOPE(R); VENTILATION; SUCCESS;
D O I
10.19224/ai2020.385
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Securing and monitoring the airways in emergency patients are among the key requirements of appropriate prehospital therapy. For spontaneously breathing patients, the indication for airway management and prehospital anaesthesia should be checked carefully. For example, non-invasive techniques that facilitate respiratory work and improve oxygenation can be used in various diseases. Since the patient is unconscious and apnoeic bag-mask ventilation should be attempted until other techniques are available. Endotracheal intubation is still the so-called "gold standard" for airway management in a prehospital setting. Video laryngoscopes have an increasing role. However, none of the currently available devices is universally applicable in every situation. In addition, the use of a video laryngoscope requires sufficient experience with this technique. To achieve a high first-pass-success, Macintosh-like blades should be routinely used and strongly curved blades should be available for special situations only. Extraglottic airways devices (EGA) are an alternative to mask ventilation and endotracheal intubation. They can be used primarily if the user does not have sufficient expe-rience in endotracheal intubation or as an alternative to failed intubation. EGA with the possibility of gastric drainage should be preferred. After successful placement, the cuff pressure should be measured and adjusted. Cricothyrotomy is the last technique for preventing a patient from severe hypoxia. It is required when oxygenation and ventilation cannot be achieved by other techniques ("cannot intubate, cannot ventilate").
引用
收藏
页码:385 / 393
页数:9
相关论文
共 47 条
[1]   Endotracheal intubation versus supraglottic airway placement in out-of-hospital cardiac arrest: A meta-analysis [J].
Benoit, Justin L. ;
Gerecht, Ryan B. ;
Steuerwald, Michael T. ;
McMullan, Jason T. .
RESUSCITATION, 2015, 93 :20-26
[2]   Prehospital airway management using the laryngeal tube. An emergency department point of view [J].
Bernhard, M. ;
Beres, W. ;
Timmermann, A. ;
Stepan, R. ;
Greim, C. -A. ;
Kaisers, U. X. ;
Gries, A. .
ANAESTHESIST, 2014, 63 (07) :589-596
[3]   The First Shot Is Often the Best Shot: First-Pass Intubation Success in Emergency Airway Management [J].
Bernhard, Michael ;
Becker, Torben K. ;
Gries, Andre ;
Knapp, Juergen ;
Wenzel, Volker .
ANESTHESIA AND ANALGESIA, 2015, 121 (05) :1389-1393
[4]  
Bernhard M, 2015, ANASTH INTENSIVMED, V56, P317
[5]   Field Use of the STORZ C-MAC™ Video Laryngoscope in Intubation Training with the Nebraska National Air Guard [J].
Boedeker, Ben H. ;
Bernhagen, Mary A. ;
Miller, David J. ;
Miljkovic, Nikola ;
Kuper, Gail M. ;
Murray, W. Bosseau .
MEDICINE MEETS VIRTUAL REALITY 18, 2011, 163 :80-82
[6]   LOWER ESOPHAGEAL SPHINCTER PRESSURE DURING PROLONGED CARDIAC-ARREST AND RESUSCITATION [J].
BOWMAN, FP ;
MENEGAZZI, JJ ;
CHECK, BD ;
DUCKETT, TM .
ANNALS OF EMERGENCY MEDICINE, 1995, 26 (02) :216-219
[7]   An easy cricothyrotomy approach: The rapid four-step technique [J].
Brofeldt, BT ;
Panacek, EA ;
Richards, JR .
ACADEMIC EMERGENCY MEDICINE, 1996, 3 (11) :1060-1063
[8]   Comparison of manikin versus porcine models in cricothyrotomy procedure training [J].
Cho, J. ;
Kang, G. H. ;
Kim, E. C. ;
Oh, Y. M. ;
Choi, H. J. ;
Im, T. H. ;
Yang, J. H. ;
Cho, Y. S. ;
Chung, H. S. .
EMERGENCY MEDICINE JOURNAL, 2008, 25 (11) :732-734
[9]   Supraglottic airway devices: recent advances [J].
Cook, Tim ;
Howes, Ben .
BJA EDUCATION, 2011, 11 (02) :56-61
[10]  
Cooper RM, 2005, CAN J ANAESTH, V52, P191, DOI 10.1007/BF03027728