Estimation of echocardiogram parameters with the aid of impedance cardiography and artificial neural networks

被引:10
作者
Ghosh, Sudipta [1 ]
Chattopadhyay, Bhabani Prasad [3 ]
Roy, Ram Mohan [3 ]
Mukherjee, Jayanta [2 ]
Mahadevappa, Manjunatha [1 ]
机构
[1] Indian Inst Technol Kharagpur, Sch Med Sci & Technol, Kharagpur 721302, W Bengal, India
[2] Indian Inst Technol Kharagpur, Dept Comp Sci & Engn, Kharagpur 721302, W Bengal, India
[3] Med Coll & Hosp, Dept Cardiol, Kolkata 700073, W Bengal, India
关键词
Impedance cardiography; Artificial neural networks; Stroke volume; Ejection fraction; Myocardial performance index; PULSE-WAVE VELOCITY; CENTRAL AORTIC PRESSURE; TRANSIT-TIME; STROKE VOLUME; VALIDATION; ALGORITHMS; STIFFNESS; FORM;
D O I
10.1016/j.artmed.2019.02.002
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The advent of cardiovascular diseases as a disease of mass catastrophy, in recent years is alarming. It is expected to spread as an epidemic by 2030. Present methods of determining the health of one's heart include doppler based echocardiogram, MDCT (Multi Detector Computed Tomography), among various other invasive and non-invasive hemodynamic monitoring techniques. These methods require expert supervision and costly clinical setups, and cannot be employed by a common individual to perform a self diagnosis of one's cardiac health, unassisted. In this work, the authors propose a novel methodology using impedance cardiography (ICG), for the determination of a person's cardio-vascular health. The recorded ICG signal helps in extraction of features which are used for estimating parameters for cardiac health monitoring. The proposed methodology with the aid of artificial neural network is able to determine Stroke Volume (SV), Left Ventricular End Systolic Volume (LVESV), Left Ventricular End Diastolic Volume (LVEDV), Left Ventricular Ejection Fraction (LVEF), Iso Volumetric Contraction Time (IVCT), Iso Volumetric Relaxation Time (IVRT), Left Ventricular Ejection Time (LVET), Total Systolic Time (TST), Total Diastolic Time (TDT), and Myocardial Performance Index (MPI), with error margins of +/- 8.9%, +/- 3.8%, +/- 1.4%, +/- 7.8%, +/- 16.0%, +/- 9.0%, +/- 9.7%, +/- 6.9%, +/- 6.2%, and +/- 0.9%, respectively. The proposed methodology could be used in screening of precursors to cardiac ailments, and to keep a check on the cardio-vascular health.
引用
收藏
页码:45 / 58
页数:14
相关论文
共 46 条
[11]   A Simple Adaptive Transfer Function for Deriving the Central Blood Pressure Waveform from a Radial Blood Pressure Waveform [J].
Gao, Mingwu ;
Rose, William C. ;
Fetics, Barry ;
Kass, David A. ;
Chen, Chen-Huan ;
Mukkamala, Ramakrishna .
SCIENTIFIC REPORTS, 2016, 6
[12]   Improved Pulse Wave Velocity Estimation Using an Arterial Tube-Load Model [J].
Gao, Mingwu ;
Zhang, Guanqun ;
Olivier, N. Bari ;
Mukkamala, Ramakrishna .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (03) :848-858
[13]  
Ghosh S, 2016, 2016 INTERNATIONAL CONFERENCE ON SYSTEMS IN MEDICINE AND BIOLOGY (ICSMB), P124, DOI 10.1109/ICSMB.2016.7915103
[14]  
Goswami D., 2011, ARTERY RES, V5, P161
[15]   A New Two-Pulse Synthesis Model for Digital Volume Pulse Signal Analysis [J].
Goswami, Dharitri ;
Chaudhuri, Koel ;
Mukherjee, Jayanta .
CARDIOVASCULAR ENGINEERING, 2010, 10 (03) :109-117
[16]   BEAT-BY-BEAT STROKE VOLUME FROM AORTIC-PULSE-PRESSURE ANALYSIS [J].
GUIER, WH ;
FRIESINGER, GC ;
ROSS, RS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1974, BM21 (04) :285-292
[17]   Full Impedance Cardiography Measurement Device Using Raspberry PI3 and System-on-Chip Biomedical Instrumentation Solutions [J].
Hafid, Abdelakram ;
Benouar, Sara ;
Kedir-talha, Malika ;
Abtahi, Farhad ;
Attari, Mokhtar ;
Seoane, Fernando .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (06) :1883-1894
[18]   Subject-Specific Estimation of Central Aortic Blood Pressure Using an Individualized Transfer Function: A Preliminary Feasibility Study [J].
Hahn, Jin-Oh ;
Reisner, Andrew T. ;
Jaffer, Farouc A. ;
Asada, H. Harry .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (02) :212-220
[19]   OPTIMAL STROKE VOLUME IN LEFT-VENTRICULAR EJECTION [J].
HAMALAINEN, JJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (02) :172-182
[20]  
HAYKIN S, 1999, NEURAL NETWORKS COMP, P318