Voltammetry at porous electrodes: A theoretical study

被引:61
作者
Barnes, Edward O. [1 ]
Chen, Xiaojun [1 ,2 ]
Li, Peilin [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[2] Nanjing Tech Univ, Coll Sci, Nanjing 211816, Jiangsu, Peoples R China
基金
英国工程与自然科学研究理事会; 中国国家自然科学基金;
关键词
Cyclic voltammetry; Diffusion within a sphere; Templated porous electrodes; Potential step chronoamperometry; EXPONENTIALLY EXPANDING MESH; PARTIALLY BLOCKED ELECTRODES; POTENTIAL-STEP CHRONOAMPEROMETRY; LINEAR SWEEP VOLTAMMETRY; MACROPOROUS GOLD FILM; MICRODISK ELECTRODES; CYCLIC VOLTAMMETRY; EFFICIENT SIMULATION; DIFFUSION-PROCESSES; ELECTROCHEMICAL DETECTION;
D O I
10.1016/j.jelechem.2014.03.028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Theory is presented to simulate both chronoamperometry and cyclic voltammetry at porous electrodes fabricated by means of electro-deposition around spherical templates. A theoretical method to extract heterogeneous rate constants for quasireversible and irreversible systems is proposed by the approximation of decoupling of the diffusion within the porous electrode and of bulk diffusion to the electrode surface. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 39 条
  • [1] Computational and experimental study of the cyclic voltammetry response of partially blocked electrodes. Part 1. Nonoverlapping, uniformly distributed blocking systems
    Brookes, BA
    Davies, TJ
    Fisher, AC
    Evans, RG
    Wilkins, SJ
    Yunus, K
    Wadhawan, JD
    Compton, RG
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 2003, 107 (07) : 1616 - 1627
  • [2] Studies in heterogeneous equilibria. Part II - The kinetic interpretation of the nernst theory of electromotive force.
    Butler, JAV
    [J]. TRANSACTIONS OF THE FARADAY SOCIETY, 1924, 19 (03): : 0729 - 0733
  • [3] Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film
    Chen, Xiaojun
    Wang, Yuanyuan
    Zhou, Jinjun
    Yan, Wei
    Li, Xinghua
    Zhu, Jun-Jie
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (06) : 2133 - 2140
  • [4] Bienzymatic glucose biosensor based on three dimensional macroporous ionic liquid doped sol-gel organic-inorganic composite
    Chen, Xiaojun
    Zhu, Jinwei
    Tian, Rong
    Yao, Cheng
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 163 (01): : 272 - 280
  • [5] Glucose biosensor based on three dimensional ordered macroporous self-doped polyaniline/Prussian blue bicomponent film
    Chen, Xiaojun
    Chen, Zixuan
    Tian, Rong
    Yan, Wei
    Yao, Cheng
    [J]. ANALYTICA CHIMICA ACTA, 2012, 723 : 94 - 100
  • [6] Room-temperature ionic liquid assisted fabrication of sensitive electrochemical immunosensor based on ordered macroporous gold film
    Chen, Xiaojun
    Zhou, Jinjun
    Xuan, Jie
    Yan, Wei
    Jiang, Li-Ping
    Zhu, Jun-Jie
    [J]. ANALYST, 2010, 135 (10) : 2629 - 2636
  • [7] Preparation of the glucose sensor based on three-dimensional ordered macroporous gold film and room temperature ionic liquid
    Chen XiaoJun
    Xuan Jie
    Jiang LiPing
    Zhu JunJie
    [J]. SCIENCE IN CHINA SERIES B-CHEMISTRY, 2009, 52 (11): : 1999 - 2005
  • [8] Numerical simulation of partially blocked electrodes under cyclic voltammetry conditions: influence of the block unit geometry on the global electrochemical properties
    Chevallier, FG
    Davies, TJ
    Klymenko, OV
    Jiang, L
    Jones, TGJ
    Compton, RG
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 577 (02) : 211 - 221
  • [9] Compton RG, 2011, UNDERSTANDING VOLTAMMETRY, 2ND EDITION, P1
  • [10] Cottrell F.G.Z., 1902, PHYS CHEM, V44, P385