Comparison of Hoffer Q and Haigis Formulae for Intraocular Lens Power Calculation According to the Anterior Chamber Depth in Short Eyes

被引:57
|
作者
Eom, Youngsub [1 ]
Kang, Su-Yeon [1 ]
Song, Jong Suk [1 ]
Kim, Yong Yeon [1 ]
Kim, Hyo Myung [1 ]
机构
[1] Korea Univ, Coll Med, Dept Ophthalmol, Seoul 136705, South Korea
关键词
OCULAR COMPONENTS; REPEATABILITY; ACCURACY;
D O I
10.1016/j.ajo.2013.12.017
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the accuracy of the Hoffer Q and Haigis formulae according to the anterior chamber depth (ACD) in cases of short axial length (AL). DESIGN: Retrospective cross-sectional study. METHODS: A total of 75 eyes from 75 patients with an AL of less than 22.0 mm implanted with an Acrysof IQ intraocular lens (TOL) were enrolled. The median absolute errors (MedAEs) predicted by the Hoffer Q and Haigis formulae were compared. The correlations between ACD and the predicted refractive error calculated using the 2 formulae were analyzed. RESULTS: There were no significant differences in the MedAEs predicted by the Hoffer Q and Haigis formulae (0.40 and 0.40 diopter [ID], respectively). The difference between the refractive errors predicted by the Hoffer Q and Haigis formulae increased significantly as the ACD decreased (R-2 = 0.644, P < .001). The MedAE predicted by the Haigis formula (0.40 D) was significantly smaller than that predicted by the Hoffer Q formula (0.66 D) in eyes with an ACD of less than 2.40 mm (P = .027). There were no significant differences found between the MedAEs predicted by the Hoffer Q and Haigis formulae in eyes with an ACD of 2.40 mm or more. CONCLUSIONS: The differences between the predicted refractive errors of the Hoffer Q and Haigis formula increased as ACD decreased in short eyes. Therefore, ACD should be taken into consideration when evaluating the accuracy of the IOL power calculation formulae in short eyes. (C) 2014 by Elsevier Inc. All rights reserved.
引用
收藏
页码:818 / 824
页数:7
相关论文
共 50 条
  • [1] Clinical Accuracy of 6 Intraocular Lens Power Calculation Formulas in Elongated Eyes, According to Anterior Chamber Depth
    Mo, Er
    Lin, Lei
    Wang, Jiangtao
    Huo, Qiuyi
    Yang, Qingwen
    Liu, Enze
    Zhang, Lu
    Yu, Yunhui
    Ye, Linying
    Pan, Anpeng
    Li, Jin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 233 : 153 - 162
  • [2] Comparison of Intraocular Lens Power Calculation Formulae in Pediatric Eyes
    Nihalani, Bharti R.
    VanderVeen, Deborah K.
    OPHTHALMOLOGY, 2010, 117 (08) : 1493 - 1499
  • [3] Intraocular lens power calculation in eyes with a shallow anterior chamber depth and normal axial length
    Lee, Yunjin
    Kim, Mee Kum
    Oh, Joo Youn
    Choi, Hyuk Jin
    Yoon, Chang Ho
    PLOS ONE, 2023, 18 (07):
  • [4] Intraocular lens power calculation in eyes with shallow anterior chamber depth and normal axial length
    Yun, Young In
    Lee, Yunjin
    Kim, Mee Kum
    Oh, Joo Youn
    Choi, Hyuk Jin
    Yoon, Chang Ho
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [5] Comparison of Two Formulae (SRK-T and Hoffer Q) for Intraocular Lens (IOL) Power Calculation in Eyes with Short Axial Length (AL) <22mm
    Dervin, Edward
    Arfat, Muhammad Yasir
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2018, 12 (03): : 1093 - 1094
  • [6] Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth
    Gao, Ruoxi
    Zhang, Jiaqing
    Han, Xiaotong
    Huang, Yiguo
    Huang, Ruoxuan
    Ye, Jinfeng
    Wen, Ling
    Qiu, Xiaozhang
    Chen, Xiaoyun
    Tan, Xuhua
    Luo, Lixia
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [7] Comparison of axial length, anterior chamber depth and intraocular lens power between IOLMaster and ultrasound in normal, long and short eyes
    Dong, Jing
    Zhang, Yaqin
    Zhang, Haining
    Jia, Zhijie
    Zhang, Suhua
    Wang, Xiaogang
    PLOS ONE, 2018, 13 (03):
  • [8] Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
    Gungor, Sirel Gur
    Akman, Ahmet
    Asena, Leyla
    Aksoy, Mustafa
    Sezenoz, Almila Sarigul
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2016, 46 (06): : 255 - 258
  • [9] Intraocular lens power calculation in short eyes
    Gavin, E. A.
    Hammond, C. J.
    EYE, 2008, 22 (07) : 935 - 938
  • [10] Intraocular lens power calculation in short eyes
    E A Gavin
    C J Hammond
    Eye, 2008, 22 : 935 - 938