Highly Sensitive Electrochemical Biosensor for Circulating Tumor Cells Detection via Dual-Aptamer Capture and Rolling Circle Amplification Strategy

被引:15
|
作者
Wang, Yang [1 ,2 ]
Chang, Kai [3 ]
Yang, Cheng [1 ]
Li, Shujing [4 ]
Wang, Lixin [3 ]
Xu, Huan [1 ]
Zhou, Lin [1 ]
Zhang, Wenqing [1 ]
Tang, Xiaoqi [1 ]
Wang, Yunxia [1 ]
Chen, Ming [1 ,2 ,5 ]
机构
[1] Army Med Univ, Mil Med Univ 3, Southwest Hosp, Dept Clin Lab Med, 30 Gaotanyan, Chongqing 400038, Peoples R China
[2] Army Med Univ, Mil Med Univ 3, Coll Pharm & Lab Med, 30 Gaotanyan, Chongqing 400038, Peoples R China
[3] Army Med Univ, Mil Med Univ 3, Daping Hosp, Dept Clin Lab Med,Inst Surg Res, 10 Changjiangzhilu, Chongqing 400042, Peoples R China
[4] Army Med Univ, Mil Med Univ 3, Southwest Hosp, Dept Nephrol, 30 Gaotanyan, Chongqing 400038, Peoples R China
[5] Army Med Univ, Mil Med Univ 3, State Key Lab Trauma Burn & Combined Injury, 30 Gaotanyan, Chongqing 400038, Peoples R China
基金
中国国家自然科学基金;
关键词
Circulating Tumor Cells; Aptamer; Electrochemical Biosensor; Rolling Circle Amplification; Detection; CANCER-CELLS; SURFACE; PROBE; NANOPARTICLES; NANOMATERIALS; RECOGNITION; ENRICHMENT; COMPOSITE; SELECTION; RELEASE;
D O I
10.1166/jbn.2019.2793
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A fast and simple strategy for early detection of circulating tumor cells (CTCs) is urgently required because of cancer metastasis. In this work, we assembled an electrochemical biosensor by two aptamers that could form hairpin and specifically recognize K562 cells. The thiolated capture aptamer was fixed on the gold electrode surface. The detection aptamer was linked with a primer at 3' end which could trigger rolling circle amplification to prolong the sequence of aptamer. The dual-aptamer model was fabricated to improve the capture specificity and efficiency for K562 cells. The rolling circle amplification improved the detection sensitivity by inhibiting electron transfer of [Fe(CN)(6)](3-/4-) which could be measured by differential pulse voltammetry. The detection limit of 25 cells mL(-1) and linear ranges of 1 x 10(2) to 1 x 10(5) cells mL(-1 )were obtained under optimal experimental conditions. Our work exhibited a label-free and simple method for detecting CTCs using cell-specific aptasensor, showing an expected possibility for further CTCs-related study and clinical applications of this novel method.
引用
收藏
页码:1568 / 1577
页数:10
相关论文
共 50 条
  • [1] Dual-Aptamer Modification Generates a Unique Interface for Highly Sensitive and Specific Electrochemical Detection of Tumor Cells
    Qu, Liming
    Xu, Jinhai
    Tan, Xiaofang
    Liu, Zhuang
    Xu, Ligeng
    Peng, Rui
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (10) : 7309 - 7315
  • [2] Combination of Immunomagnetic Separation with Aptamer-Mediated Double Rolling Circle Amplification for Highly Sensitive Circulating Tumor Cell Detection
    Sun, Shujuan
    Yang, Shulin
    Hu, Xuemei
    Zheng, Cheng
    Song, Huanxia
    Wang, Lisha
    Shen, Zhifa
    Wu, Zai-Sheng
    ACS SENSORS, 2020, 5 (12): : 3870 - 3878
  • [3] Highly sensitive and specific colorimetric detection of cancer cells via dual-aptamer target binding strategy
    Wang, Kun
    Fan, Daoqing
    Liu, Yaqing
    Wang, Erkang
    BIOSENSORS & BIOELECTRONICS, 2015, 73 : 1 - 6
  • [4] Highly sensitive electrochemical detection of circulating EpCAM-positive tumor cells using a dual signal amplification strategy
    Hashkavayi, Ayemeh Bagheri
    Cha, Byung Seok
    Hwang, Sung Hyun
    Kim, Jimin
    Park, Ki Soo
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
  • [5] Nondestructive separation/enrichment and rolling circle amplification-powered sensitive SERS enumeration of circulating tumor cells via aptamer recognition
    Li, Jinxiang
    Dong, Chen
    Gan, Hongyu
    Gu, Xinyue
    Zhang, Jingjing
    Zhu, Yunfeng
    Xiong, Jingrong
    Song, Chunyuan
    Wang, Lianhui
    BIOSENSORS & BIOELECTRONICS, 2023, 231
  • [6] Aptamer-based and highly sensitive electrochemical label-free gliotoxin biosensor via a dual recycling signal amplification cascade strategy
    Wang, Hao
    Zhao, Yi
    Liu, Juan
    Yuan, Ruo
    Xiang, Yun
    TALANTA, 2025, 290
  • [7] Electrochemical Detection of Circulating Tumor Cells Based on DNA Generated Electrochemical Current and Rolling Circle Amplification
    Shen, Congcong
    Liu, Shuping
    Li, Xiaoqing
    Yang, Minghui
    ANALYTICAL CHEMISTRY, 2019, 91 (18) : 11614 - 11619
  • [8] Electrochemical aptasensor for highly sensitive determination of cocaine using a supramolecular aptamer and rolling circle amplification
    Bo Shen
    Jianbo Li
    Wei Cheng
    Yurong Yan
    Renkuan Tang
    Yongguo Li
    Huangxian Ju
    Shijia Ding
    Microchimica Acta, 2015, 182 : 361 - 367
  • [9] Electrochemical aptasensor for highly sensitive determination of cocaine using a supramolecular aptamer and rolling circle amplification
    Shen, Bo
    Li, Jianbo
    Cheng, Wei
    Yan, Yurong
    Tang, Renkuan
    Li, Yongguo
    Ju, Huangxian
    Ding, Shijia
    MICROCHIMICA ACTA, 2015, 182 (1-2) : 361 - 367
  • [10] In Situ-Generated Multivalent Aptamer Network for Efficient Capture and Sensitive Electrochemical Detection of Circulating Tumor Cells in Whole Blood
    Yang, Jianmei
    Li, Xiaolong
    Jiang, Bingying
    Yuan, Ruo
    Xiang, Yun
    ANALYTICAL CHEMISTRY, 2020, 92 (11) : 7893 - 7899