Background: In this study, computed tomography/magnetic resonance imaging (CT/MRI) image registration and fusion in the 3D conformal radiotherapy treatment planning of Glioblastoma brain tumor was investigated. Good CT/MRI image registration and fusion made a great impact on dose calculation and treatment planning accuracy. Indeed, the uncertainly associated with the registration and fusion methods must be well verified and communicated. Unfortunately, there is no standard procedure or mathematical formalism to perform this verification due to noise, distortion, and complicated anatomical situations. Objectives: This study aimed at assessing the effective contribution of MRI in Glioma radiotherapy treatment by improving the localization of target volumes and organs at risk (OARs). It is also a question to provide clinicians with some suitable metrics to evaluate the CT/MRI image registration and fusion results. Methods: Quantitative image registration and fusion evaluation were used in this study to compare Eclipse TPS tools and Elastix CT/MRI image registration fusion. Thus, Dice score coefficient (DSC), Jaccard similarity coefficient (JSC), and Hausdorff distance (HD) were found to be suitable metrics for the evaluation and comparison of the image registration and fusion methods of Eclipse TPS and Elastix. Results: The programmed tumor's volumes (PTV) delineated on CT slices were approximately 1.38 times smaller than those delineated on CT/MRI fused images. Large differences were observed for the edema and the brainstem. It was also found that MRI considerably optimized the dose to be delivered to the optic nerve and brainstem. Conclusions: Image registration and fusion is a fundamental step for suitable and efficient Glioma treatment planning in 3D conformal radiotherapy that ensure accurate dose delivery and unnecessary OAR irradiation. MRI can provide accurate localization of targeted volumes leading to better irradiation control of Glioma tumor.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Domain adaptation of automated treatment planning from computed tomography to magnetic resonance
    Khalifa, Aly
    Winter, Jeff
    Navarro, Inmaculada
    McIntosh, Chris
    Purdie, Thomas G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (12)
  • [32] Developing quality assurance tests for simultaneous Positron Emission Tomography - Magnetic Resonance imaging for radiotherapy planning
    Wyatt, Jonathan J.
    McCallum, Hazel M.
    Maxwell, Ross J.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 22 : 28 - 35
  • [33] Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration
    Parker, CC
    Damyanovich, A
    Haycocks, T
    Haider, M
    Bayley, A
    Catton, CN
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) : 217 - 224
  • [34] Interest of positron-emission tomography and magnetic resonance imaging for radiotherapy planning and control
    Crehange, G.
    Soussan, M.
    Gensanne, D.
    Decazes, P.
    Thariat, J.
    Thureau, S.
    CANCER RADIOTHERAPIE, 2020, 24 (05): : 398 - 402
  • [35] Computed tomography and magnetic resonance imaging assessment of aortic valve stenosis: an update
    Choe, Yeon Hyeon
    Kim, Sung Mok
    Park, Sung-Ji
    PRECISION AND FUTURE MEDICINE, 2020, 4 (04): : 119 - 132
  • [36] Synthetic computed tomography data allows for accurate absorbed dose calculations in a magnetic resonance imaging only workflow for head and neck radiotherapy
    Palmer, Emilia
    Karlsson, Anna
    Nordstrom, Fredrik
    Petruson, Karin
    Siversson, Carl
    Ljungberg, Maria
    Sohlin, Maja
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 36 - 42
  • [37] Magnetic resonance spectroscopy imaging (MRSI) and brain functional magnetic resonance imaging (fMRI) for radiotherapy treatment planning of glioma
    Chang, Jenghwa
    Thakur, Sunitha B.
    Huang, Wei
    Narayana, Ashwatha
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (05) : 349 - 362
  • [38] The Role of Computed Tomography and Magnetic Resonance Imaging in Accurate Size Estimation of Pancreatic Ductal Adenocarcinoma
    Alabousi, Mostafa
    Patlas, Michael N.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2023, 74 (03): : 478 - 479
  • [39] An Inter-observer Study to Determine Radiotherapy Planning Target Volumes for Recurrent Gynaecological Cancer Comparing Magnetic Resonance Imaging Only With Computed Tomography-Magnetic Resonance Imaging
    Bernstein, D.
    Taylor, A.
    Nill, S.
    Imseeh, G.
    Kothari, G.
    Llewelyn, M.
    De Paepe, K. N.
    Rockall, A.
    Shiarli, A-M
    Oelfke, U.
    CLINICAL ONCOLOGY, 2021, 33 (05) : 307 - 313
  • [40] COMPUTED-TOMOGRAPHY (CT) AND MAGNETIC-RESONANCE-IMAGING (MRI) IN T-STAGE EVALUATION OF ORAL AND OROPHARYNGEAL CARCINOMAS
    BOOTZ, F
    LENZ, M
    SKALEJ, M
    BONGERS, H
    CLINICAL OTOLARYNGOLOGY, 1992, 17 (05): : 421 - 429