Technical Assessment of an Automated Treatment Planning on Dose Escalation of Pancreas Stereotactic Body Radiotherapy

被引:4
|
作者
Wang, Shuo [1 ]
Zheng, Dandan [1 ]
Lin, Chi [1 ]
Lei, Yu [1 ]
Verma, Vivek [2 ]
Smith, April [1 ]
Ma, Rongtao [3 ]
Enke, Charles A. [1 ]
Zhou, Sumin [1 ]
机构
[1] Univ Nebraska, Dept Radiat Oncol, Med Ctr, Omaha, NE 68198 USA
[2] Allegheny Gen Hosp, Pittsburgh, PA 15212 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, 1275 York Ave, New York, NY 10021 USA
关键词
stereotactic body radiotherapy; pancreatic cancer; automated treatment planning; dose escalation; personalized treatment; RADIATION-THERAPY SMART; ADAPTIVE RADIOTHERAPY; DE-ESCALATION; PHASE-II; CANCER; IMRT; RADIOSURGERY; GEMCITABINE; HEAD; ADENOCARCINOMA;
D O I
10.1177/1533033819851520
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Stereotactic body radiotherapy has been suggested to provide high rates of local control for locally advanced pancreatic cancer. However, the close proximity of highly radiosensitive normal tissues usually causes the labor-intensive planning process and may impede further escalation of the prescription dose. Purpose: The present study aims to evaluate the consistency and efficiency of Pinnacle Auto-Planning for pancreas stereotactic body radiotherapy with original prescription and escalated prescription. Methods: Twenty-four patients with pancreatic cancer treated with stereotactic body radiotherapy were studied retrospectively. The prescription is 40 Gy over 5 consecutive fractions. Most of patients (n = 21) also had 3 other different dose-level targets (6 Gy/fraction, 5 Gy/fraction, and 4 Gy/fraction). Two types of plans were generated by Pinnacle Auto-Planning with the original prescription (8 Gy/fraction, 6 Gy/fraction, 5 Gy/fraction, and 4 Gy/fraction) and escalated prescription (9 Gy/fraction, 7 Gy/fraction, 6 Gy/fraction, and 5 Gy/fraction), respectively. The same Auto-Planning template, including beam geometry, intensity-modulated radiotherapy objectives and intensity-modulated radiotherapy optimization parameters, were utilized for all the auto-plans in each prescription group. The intensity-modulated radiotherapy objectives do not include any manually created structures. Dosimetric parameters including percentage volume of PTV receiving 100% of the prescription dose, percentage volume of PTV receiving 93% of the prescription dose, and consistency of the dose-volume histograms of the target volumes were assessed. D-max and D-1 cc of highly radiosensitive organs were also evaluated. Results: For all the pancreas stereotactic body radiotherapy plans with the original or escalated prescriptions, auto-plans met institutional dose constraints for critical organs, such as the duodenum, small intestine, and stomach. Furthermore, auto-plans resulted in acceptable planning target volume coverage for all targets with different prescription levels. All the plans were generated in a one-attempt manner, and very little human intervention is necessary to achieve such plan quality. Conclusions: Pinnacle(3) Auto-Planning consistently and efficiently generate acceptable treatment plans for multitarget pancreas stereotactic body radiotherapy with or without dose escalation and may play a more important role in treatment planning in the future.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [41] Dose escalation for prostate stereotactic ablative radiotherapy (SABR): Late outcomes from two prospective clinical trials
    Alayed, Yasir
    Cheung, Patrick
    Pang, Geordi
    Mamedov, Alexandre
    D'Alimonte, Laura
    Deabreu, Andrea
    Commisso, Kristina
    Commisso, Angela
    Zhang, Liang
    Quon, Harvey C.
    Musunuru, Hima Bindu
    Helou, Joelle
    Loblaw, D. Andrew
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 (02) : 213 - 218
  • [42] Optimization of stereotactic body radiotherapy treatment planning using a multicriteria optimization algorithm
    Ghandour, Sarah
    Cosinschi, Adrien
    Mazouni, Zohra
    Pachoud, Marc
    Matzinger, Oscar
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (04): : 362 - 370
  • [43] Questionnaire survey on treatment planning techniques for lung stereotactic body radiotherapy in Japan
    Ueda, Yoshihiro
    Takakura, Toru
    Ota, Seiichi
    Kito, Satoshi
    Sasaki, Koji
    Shimizu, Hidetoshi
    Tatsumi, Daisaku
    Yano, Shinsuke
    Nakamura, Mitsuhiro
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (01) : 104 - 116
  • [44] Clinical introduction of Monte Carlo treatment planning for lung stereotactic body radiotherapy
    Miura, Hideharu
    Masai, Norihisa
    Oh, Ryoong-Jin
    Shiomi, Hiroya
    Yamada, Kouichi
    Sasaki, Junichi
    Inoue, Toshihiko
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 38 - 46
  • [45] A quantitative treatment planning study evaluating the potential of dose escalation in conformal radiotherapy of the oesophagus
    Bedford, JL
    Viviers, L
    Guzel, Z
    Childs, PJ
    Webb, S
    Tait, DM
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) : 183 - 193
  • [46] Approach and assessment of automated stereotactic radiotherapy planning for early stage non-small-cell lung cancer
    Bai, Xue
    Shan, Guoping
    Chen, Ming
    Wang, Binbing
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (01)
  • [47] Stereotactic Ablative Body Radiotherapy for the Treatment of Spinal Oligometastases
    Chang, J. H.
    Gandhidasan, S.
    Finnigan, R.
    Whalley, D.
    Nair, R.
    Herschtal, A.
    Eade, T.
    Kneebone, A.
    Ruben, J.
    Foote, M.
    Siva, S.
    CLINICAL ONCOLOGY, 2017, 29 (07) : E119 - E125
  • [48] Dose-Volume Histogram Analysis of Stereotactic Body Radiotherapy Treatment of Pancreatic Cancer: A Focus on Duodenal Dose Constraints
    Goldsmith, Christy
    Price, Patricia
    Cross, Timothy
    Loughlin, Sheila
    Cowley, Ian
    Plowman, Nicholas
    SEMINARS IN RADIATION ONCOLOGY, 2016, 26 (02) : 149 - 156
  • [49] Dose escalation of Stereotactic Body Radiotherapy (SBRT) for locally advanced unresectable pancreatic cancer patients with CyberKnife: protocol of a phase I study
    Qing, Shui-Wang
    Ju, Xiao-Ping
    Cao, Yang-Sen
    Zhang, Huo-Jun
    RADIATION ONCOLOGY, 2017, 12
  • [50] Phase I dose-escalation study of stereotactic body radiotherapy (SBRT) for poor surgical candidates with localized renal cell carcinoma
    Ponsky, Lee
    Lo, Simon S.
    Zhang, Yuxia
    Schluchter, Mark
    Liu, Yiying
    Patel, Ravi
    Abouassaly, Robert
    Welford, Scott
    Gulani, Vikas
    Haaga, John Robert
    Machtay, Mitchell
    Ellis, Rodney J.
    RADIOTHERAPY AND ONCOLOGY, 2015, 117 (01) : 183 - 187