Real-Time Image Reconstruction for Low-Dose CT using Deep Convolutional Generative Adversarial Networks (GANs)

被引:11
作者
Choi, Kihwan [1 ]
Kim, Sung Won [2 ]
Lim, Joon Seok [2 ]
机构
[1] Korea Inst Sci & Technol, Ctr Bion, Seoul 02792, South Korea
[2] Yonsei Univ, Coll Med, Dept Radiol, Seoul 03722, South Korea
来源
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING | 2018年 / 10573卷
关键词
Deep learning; low-dose CT; iterative reconstruction; generative adversarial network (GAN); BEAM COMPUTED-TOMOGRAPHY; PROJECTION DATA;
D O I
10.1117/12.2293420
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper introduces a deep learning network that reconstructs low-dose CT images into CT images of a high quality comparable to adaptive statistical iterative reconstruction (ASIR) as fast as filtered backprojection (FBP). Fully convolutional networks (FCNs) are adopted to denoise the low-dose CT images reconstructed with FBP. In contrast to patch-based convolutional neural networks (CNNs), we train the FCN-based denoising network with full-size images, which is computationally efficient due to the reuse of feature maps from the lower layers. To guarantee that the resultant high-quality images are consistent with the input images, a CNN-based classifier is added to the denoising network during the training phase. The classifier incorporates the CT noise model and evaluates the consistency between the images reconstructed with FBP and those of the denoising network. This supplementary structure makes the entire network a class of generative adversarial networks (GANs). For training and testing the network, we use a dataset of 18 patients who have undergone abdominal low-dose CT with both FBP and ASIR, which we split into a training set of 12 patients and a validation set of the remaining 6 patients. After being trained with FBP and ASIR image pairs, the GAN successfully recovers the high-quality images from the noisy CT images reconstructed with FBP. The network, by using a moderate GPU, is computationally efficient in recovering each image within 0.1 second. It is also remarkable that the GAN successfully preserves the image details, whereas ASIR is known for its occasional failure to recover small low-contrast features.
引用
收藏
页数:6
相关论文
共 33 条
[1]  
[Anonymous], 2017, ARXIV170200288
[2]  
[Anonymous], 2009, Computed tomography: principles, design, artifacts, and recent advances
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[5]   Low-dose CT via convolutional neural network [J].
Chen, Hu ;
Zhang, Yi ;
Zhang, Weihua ;
Liao, Peixi ;
Li, Ke ;
Zhou, Jiliu ;
Wang, Ge .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (02) :679-694
[6]   Artifact Suppressed Dictionary Learning for Low-Dose CT Image Processing [J].
Chen, Yang ;
Shi, Luyao ;
Feng, Qianjing ;
Yang, Jian ;
Shu, Huazhong ;
Luo, Limin ;
Coatrieux, Jean-Louis ;
Chen, Wufan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (12) :2271-2292
[7]   Improving abdomen tumor low-dose CT images using a fast dictionary learning based processing [J].
Chen, Yang ;
Yin, Xindao ;
Shi, Luyao ;
Shu, Huazhong ;
Luo, Limin ;
Coatrieux, Jean-Louis ;
Toumoulin, Christine .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16) :5803-5820
[8]   First study of on-treatment volumetric imaging during respiratory gated VMAT [J].
Choi, Kihwan ;
Xing, Lei ;
Koong, Albert ;
Lia, Ruijiang .
MEDICAL PHYSICS, 2013, 40 (04)
[9]   Compressed sensing based cone-beam computed tomography reconstruction with a first-order method [J].
Choi, Kihwan ;
Wang, Jing ;
Zhu, Lei ;
Suh, Tae-Suk ;
Boyd, Stephen ;
Xing, Lei .
MEDICAL PHYSICS, 2010, 37 (09) :5113-5125
[10]  
Goodfellow I, 2016, ADAPT COMPUT MACH LE, P1