Long-Term Effects of Hospital Water Network Disinfection on Legionella and Other Waterborne Bacteria in an Italian University Hospital

被引:44
作者
Casini, Beatrice [1 ]
Buzzigoli, Andrea [1 ]
Cristina, Maria Luisa [2 ]
Spagnolo, Anna Maria [2 ]
Del Giudice, Pietro [3 ]
Brusaferro, Silvio [3 ]
Poscia, Andrea [4 ]
Moscato, Umberto [4 ]
Valentini, Paola [1 ]
Baggiani, Angelo [1 ]
Privitera, Gaetano [1 ]
机构
[1] Univ Pisa, Dept Translat Res, I-56127 Pisa, Italy
[2] Univ Genoa, Dept Hlth Sci, Genoa, Italy
[3] Univ Udine, Dept Med & Biol Sci, I-33100 Udine, Italy
[4] Univ Cattolica Sacro Cuore, Inst Hyg, Welf Dept Publ Hlth, I-00168 Rome, Italy
关键词
DRINKING-WATER; MYCOBACTERIA; PNEUMOPHILA; PERSISTENCE; COLONIZATION; PREVENTION; PATHOGENS; SYSTEMS;
D O I
10.1086/675280
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective and Design.Legionella control still remains a critical issue in healthcare settings where the preferred approach to health risk assessment and management is to develop a water safety plan. We report the experience of a university hospital, where a water safety plan has been applied since 2002, and the results obtained with the application of different methods for disinfecting hot water distribution systems in order to provide guidance for the management of water risk.Interventions.The disinfection procedures included continuous chlorination with chlorine dioxide (0.4--0.6 mg/L in recirculation loops) reinforced by endpoint filtration in critical areas and a water treatment based on monochloramine (2--3 mg/L). Real-time polymerase chain reaction and a new immunoseparation and adenosine triphosphate bioluminescence analysis were applied in environmental monitoring.Results.After 9 years, the integrated disinfection-filtration strategy significantly reduced positive sites by 55% and the mean count by 78% (P < .05); however, the high costs and the occurrence of a chlorine-tolerant clone belonging to Legionella pneumophila ST269 prompted us to test a new disinfectant. The shift to monochloramine allowed us to eliminate planktonic Legionella and did not require additional endpoint filtration; however, nontuberculous mycobacteria were isolated more frequently as long as the monochloramine concentration was 2 mg/L; their cultivability was never regained by increasing the concentration up to 3 mg/L.Conclusions.Any disinfection method needs to be adjusted/fine-tuned in individual hospitals in order to maintain satisfactory results over time, and only a locally adapted evidence-based approach allows assessment of the efficacy and disadvantages of the control measures.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 39 条
[21]  
Joseph CA, 2007, EURO SURVEILL, V15
[22]   An international trial of quantitative PCR for monitoring Legionella in artificial water systems [J].
Lee, J. V. ;
Lai, S. ;
Exner, M. ;
Lenz, J. ;
Gaia, V. ;
Casati, S. ;
Hartemann, P. ;
Lueck, C. ;
Pangon, B. ;
Ricci, M. L. ;
Scaturro, M. ;
Fontana, S. ;
Sabria, M. ;
Sanchez, I. ;
Assaf, S. ;
Surman-Lee, S. .
JOURNAL OF APPLIED MICROBIOLOGY, 2011, 110 (04) :1032-1044
[23]   Controlling Legionella in Hospital Drinking Water: An Evidence-Based Review of Disinfection Methods [J].
Lin, Yusen E. ;
Stout, Janet E. ;
Yu, Victor L. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2011, 32 (02) :166-173
[24]   Control of Legionella contamination in a hospital water distribution system by monochloramine [J].
Marchesi, Isabella ;
Cencetti, Stefano ;
Marchegiano, Patrizia ;
Frezza, Giuseppina ;
Borella, Paola ;
Bargellini, Annalisa .
AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (03) :279-281
[25]  
MURACA PW, 1990, INFECT CONT HOSP EP, V11, P79, DOI 10.1086/646126
[26]  
Pedley S., 2004, PATH MYC WAT GUID PU
[27]   Persistent Legionella pneumophila colonization of a hospital water supply:: efficacy of control methods and a molecular epidemiological analysis [J].
Perola, O ;
Kauppinen, J ;
Kusnetsov, J ;
Kärkkäinen, UM ;
Lück, PC ;
Katila, ML .
APMIS, 2005, 113 (01) :45-53
[28]   RAPID, AMPLIFICATION-BASED FINGERPRINTING OF MYCOBACTERIUM-TUBERCULOSIS [J].
PLIKAYTIS, BB ;
CRAWFORD, JT ;
WOODLEY, CL ;
BUTLER, WR ;
EISENACH, KD ;
CAVE, MD ;
SHINNICK, TM .
JOURNAL OF GENERAL MICROBIOLOGY, 1993, 139 :1537-1542
[29]   Investigation of opportunistic pathogens in municipal drinking water under different supply and treatment regimes [J].
Pryor, M ;
Springthorpe, S ;
Riffard, S ;
Brooks, T ;
Huo, Y ;
Davis, G ;
Satter, SA .
WATER SCIENCE AND TECHNOLOGY, 2004, 50 (01) :83-90
[30]   Persistence of Legionella pneumophila in a hospital's water system:: A 13-year survey [J].
Rangel-Frausto, MS ;
Rhomberg, P ;
Hollis, RJ ;
Pfaller, MA ;
Wenzel, RP ;
Helms, CM ;
Herwaldt, LA .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1999, 20 (12) :793-797