Novel method of calibration with restrictive constraints for stereo-vision system

被引:21
作者
Cui, Jiashan [1 ]
Huo, Ju [2 ]
Yang, Ming [1 ]
机构
[1] Harbin Inst Technol, Control & Simulat Ctr, Harbin 150006, Peoples R China
[2] Harbin Inst Technol, Dept Elect Engn, Harbin 150006, Peoples R China
基金
中国国家自然科学基金;
关键词
stereo vision; calibration; bundle adjustment; cross target;
D O I
10.1080/09500340.2015.1106602
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Regarding the calibration of a stereo vision measurement system, this paper puts forward a new bundle adjustment algorithm based on the stereo vision camera calibration method. Multiple-viewgeometricconstraintsanda bundle adjustment algorithm are used to optimizethe inner and outer parametersof thecamera accurately. A fixed relative constraint relationship between cameras is introduced. We have improved the normal equation construction process of the traditional bundle adjustment method, so that each iteration process occurs just outside the parameters of two images that are taken by a camera that has been optimized to better integrate two cameras bound together as one camera. The relationship between the fixed relative constraints can effectively increase the number of superfluous observations of the adjustment system and optimize higher accuracy while reducing the dimension of the normal matrix; it means that each iteration will reduce the time required. Simulation and actual experimental results show the superior performance of the proposed approach in terms of robustness and accuracy, and our approach also can be extended to stereo-vision system with more than two cameras.
引用
收藏
页码:835 / 846
页数:12
相关论文
共 17 条
[1]   Complete calibration of a stereo photogrammetric system through control points of unknown coordinates [J].
Cerveri, P ;
Borghese, NA ;
Pedotti, A .
JOURNAL OF BIOMECHANICS, 1998, 31 (10) :935-940
[2]   The high precision positioning algorithm of circular landmark center in visual measurement [J].
Cui, Jiashan ;
Huo, Ju ;
Yang, Ming .
OPTIK, 2014, 125 (21) :6570-6575
[3]  
David D., 2000, P ECCV, V1843, P625
[4]   An expert measurement system for photogrammetric industrial application [J].
Ergün, B .
MEASUREMENT, 2006, 39 (05) :415-419
[5]  
Hartley R, 1992, P ECCV 92, V588, P579
[6]   CAMERA CALIBRATION WITH BASELINE DISTANCE CONSTRAINTS [J].
Lerma, Jose L. ;
Navarro, Santiago ;
Cabrelles, Miriam ;
Segui, Ana E. .
PHOTOGRAMMETRIC RECORD, 2010, 25 (130) :140-158
[7]   Method of rotation angle measurement in machine vision based on calibration pattern with spot array [J].
Li, Weimin ;
Jin, Jing ;
Li, Xiaofeng ;
Li, Bin .
APPLIED OPTICS, 2010, 49 (06) :1001-1006
[8]   Estimating Relative Camera Motion from the Antipodal-Epipolar Constraint [J].
Lim, John ;
Barnes, Nick ;
Li, Hongdong .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2010, 32 (10) :1907-U188
[9]  
Ling Zhou, 2007, Journal of Applied Sciences, V25, P288
[10]  
Malm H, 2001, PROC CVPR IEEE, P657