Design and fabrication of a piezoelectric MEMS xylophone transducer with a flexible electrical connection

被引:17
作者
Zhao, Chuming [1 ]
Knisely, Katherine E. [1 ,3 ]
Grosh, Karl [1 ,2 ]
机构
[1] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Biomed Engn Dept, Ann Arbor, MI 48109 USA
[3] Sandia Natl Labs, PO 5800, Albuquerque, NM 87123 USA
关键词
MEMS; Acoustic transducers; Aluminum nitride (AIN); Piezoelectric transducers; Micro cantilever beams; Finite element analysis (FEA); Acoustic structure interaction; Flexible parylene cable; Bonding; Cochlear implant; ARTIFICIAL BASILAR-MEMBRANE; CANTILEVER ARRAY; FREQUENCY-SELECTIVITY; VIBRATION; ELECTRODE; COCHLEA; LIQUID;
D O I
10.1016/j.sna.2018.03.038
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We develop a method for the design and fabrication of a miniaturized multichannel piezoelectric xylophone acoustic transducer with an integrated flexible ribbon cable for electrical connectivity. This transducer works in air or underwater and it is designed to be implantable for in vivo animal testing. The transducer and ribbon cable are fabricated separately using microelectromechanical systems (MEMS) techniques, and bonded with a customized wire -epoxy bonding technique. The transducer has a xylophone structure which consists of four piezoelectric bimorph cantilevers of varied lengths each tuned to a target frequency bandwidth. A parylene ribbon cable extends from the base of the xylophone to an electrode bay for external monitoring. Cantilever tip deflections are measured in response to voltage excitation to confirm the transducer functionality in air and underwater as well as to validate the finite element analysis (FEA) model, which is developed to design the transducer and study the acoustic structure interaction of the cantilever beam in a viscous fluid environment. The frequency response of the model matches closely with the measured results. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 57 条
[1]  
Ando S, 1997, TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, P1027, DOI 10.1109/SENSOR.1997.635360
[2]  
[Anonymous], 2016, Sensation and perception
[3]   Micromechanical resonator array for an implantable bionic ear [J].
Bachman, M ;
Zeng, FG ;
Xu, T ;
Li, GP .
AUDIOLOGY AND NEURO-OTOLOGY, 2006, 11 (02) :95-103
[4]   Hydrodynamic loading of microcantilevers vibrating in viscous fluids [J].
Basak, Sudipta ;
Raman, Arvind ;
Garimella, Suresh V. .
JOURNAL OF APPLIED PHYSICS, 2006, 99 (11)
[5]   A 32-site 4-channel high-density electrode array for a cochlear prosthesis [J].
Bhatti, Pamela T. ;
Wise, Kensall D. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2006, 41 (12) :2965-2973
[6]   Initial clinical experience with a totally implantable cochlear implant research device [J].
Briggs, Robert J. S. ;
Eder, Helmut C. ;
Seligman, Peter M. ;
Cowan, Robert S. C. ;
Plant, Kerrie L. ;
Dalton, James ;
Money, David K. ;
Patrick, James F. .
OTOLOGY & NEUROTOLOGY, 2008, 29 (02) :114-119
[7]  
Brock K, 2012, AM COLL LAB, P503, DOI 10.1016/B978-0-12-380920-9.00017-1
[8]   A hydromechanical biomimetic cochlea: Experiments and models [J].
Chen, FY ;
Cohen, HI ;
Bifano, TG ;
Castle, J ;
Fortin, J ;
Kapusta, C ;
Mountain, DC ;
Zosuls, A ;
Hubbard, AE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (01) :394-405
[9]  
COMSOL Inc, 2016, COMSOL MULT 5 2A
[10]  
Dallos P., 1996, COCHLEA SPRINGER HDB, V8