Layer-by-layer assembled hybrid film of carbon nanotubes/iron oxide nanocrystals for reagentless electrochemical detection of H2O2

被引:38
作者
Miao, Yuqing [1 ,2 ]
Wang, Hua [2 ]
Shao, Yuyan [2 ]
Tang, Zhiwen [2 ]
Wang, Jun [2 ]
Lin, Yuehe [2 ]
机构
[1] Zhejiang Normal Univ, Inst Phys Chem, Zhejiang Key Lab React Chem Solid Surfaces, Jinhua 321004, Peoples R China
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
基金
中国国家自然科学基金;
关键词
Carbon nanotube; Magnetic nanocystals; Peroxidase mimetics; H2O2; BIOMEDICAL APPLICATIONS; MAGNETIC NANOPARTICLES; MODIFIED ELECTRODE; GLUCOSE DETECTION; THIONINE; BIOSENSOR; FE3O4; SURFACE;
D O I
10.1016/j.snb.2008.12.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new approach to construct a reagentless electrochemical H2O2 sensor is described. Iron oxide magnetic nanocystals (IOMNs), as peroxidase mimetics, were assembled to form a multilayer structure through the layer-by-layer (LBL) method. Polythionin (PTh) was first electrodeposited onto the glassy carbon electrode (GCE) surface to introduce amino groups. Carboxyl functionalized multi-walled carbon nanotubes (MWCNTs), amino functionalized IOMNs, and thionin monomers were alternatively anchored onto a polythionin-functionalized GCE surface in order by carbodiimide or glutaraldehyde chemistry. The resulting multilayer construction with three layers of IOMNs and thionin mediator exhibits excellent electrochemical response to the reduction of H2O2, whereas such a modified electrode with one layer construction only yields a slight response to H2O2 of the same concentration. The tethered MWCNTs enlarge the amount of immobilized ICMNs and effectively shuttle electrons between the electrode and the thionin. The calibration plot is linear over the wide H2O2 concentration range from 0.099 to 6.54 mM, with a detection limit of 53.6 mu M. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 23 条
[1]   Electrochemical sensor for hydroperoxides determination based on Prussian blue film modified electrode [J].
Adhoum, Nafaa ;
Monser, Lotfi .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (02) :588-592
[2]   Water-soluble carbon nanotube-enzyme conjugates as functional biocatalytic formulations [J].
Asuri, Prashanth ;
Karajanagi, Sandeep S. ;
Sellitto, Edward ;
Kim, Dae-Yun ;
Kane, Ravi S. ;
Dordick, Jonathan S. .
BIOTECHNOLOGY AND BIOENGINEERING, 2006, 95 (05) :804-811
[3]   Characterization of aqueous dispersions of Fe3O4 nanoparticles and their biomedical applications [J].
Cheng, FY ;
Su, CH ;
Yang, YS ;
Yeh, CS ;
Tsai, CY ;
Wu, CL ;
Wu, MT ;
Shieh, DB .
BIOMATERIALS, 2005, 26 (07) :729-738
[4]   Intrinsic peroxidase-like activity of ferromagnetic nanoparticles [J].
Gao, Lizeng ;
Zhuang, Jie ;
Nie, Leng ;
Zhang, Jinbin ;
Zhang, Yu ;
Gu, Ning ;
Wang, Taihong ;
Feng, Jing ;
Yang, Dongling ;
Perrett, Sarah ;
Yan, Xiyun .
NATURE NANOTECHNOLOGY, 2007, 2 (09) :577-583
[5]   Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications [J].
Gupta, AK ;
Gupta, M .
BIOMATERIALS, 2005, 26 (18) :3995-4021
[6]   A thionine functionalized multiwalled carbon nanotube modified electrode for the determination of hydrogen peroxide [J].
Jeykumari, D. R. Shobha ;
Ramaprabhu, S. ;
Narayanan, S. Sriman .
CARBON, 2007, 45 (06) :1340-1353
[7]   Protein immobilization on carbon nanotubes via a two-step process of diimide-activated amidation [J].
Jiang, KY ;
Schadler, LS ;
Siegel, RW ;
Zhang, XJ ;
Zhang, HF ;
Terrones, M .
JOURNAL OF MATERIALS CHEMISTRY, 2004, 14 (01) :37-39
[8]   Thionine-mediated chemistry of carbon nanotubes [J].
Li, QW ;
Zhang, J ;
Yan, H ;
He, MS ;
Liu, ZF .
CARBON, 2004, 42 (02) :287-291
[9]  
Lian G., 2004, MICROSC MICROANAL, V10, P536
[10]   Application of nanosized Fe3O4 in anticancer drug carriers with target-orientation and sustained-release properties [J].
Lin, Ben-Lan ;
Shen, Xiao-Dong ;
Cui, Sheng .
BIOMEDICAL MATERIALS, 2007, 2 (02) :132-134