Biofunctionalized Graphene Quantum Dots Based Fluorescent Biosensor toward Efficient Detection of Small Cell Lung Cancer

被引:135
作者
Kalkal, Ashish [1 ]
Pradhan, Rangadhar [2 ]
Kadian, Sachin [3 ]
Manik, Gaurav [3 ]
Packirisamy, Gopinath [1 ,2 ]
机构
[1] Indian Inst Technol Roorkee, Dept Biotechnol, Roorkee 247667, Uttarakhand, India
[2] Indian Inst Technol Roorkee, Ctr Nanotechnol, Roorkee 247667, Uttarakhand, India
[3] Indian Inst Technol Roorkee, Dept Polymer & Proc Engn, Roorkee 247667, Uttrakhand, India
关键词
biosensor; graphene quantum dots (GQDs); energy transfer; small cell lung cancer (SCLC); biomarker; NEURON-SPECIFIC ENOLASE; ENERGY-TRANSFER FRET; LABEL-FREE DETECTION; CARBON DOTS; IMMUNOSENSOR; RECOGNITION; MEMBRANE; NANODOTS; PLATFORM; GREEN;
D O I
10.1021/acsabm.0c00427
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Quantitative detection of cancer biomarkers with higher accuracy and sensitivity provides an effective platform for screening, monitoring, early diagnosis, and disease surveillance. The present work demonstrates the fabrication and application of fluorescent turn-on biosensor for ultrasensitive detection of small cell lung cancer biomarker utilizing biofunctionalized graphene quantum dots as the energy donor and gold nanoparticles (AuNPs) as the energy acceptor. One-pot and the bottom-up hydrothermal route have been employed for the synthesis of in situ amine-functionalized and nitrogen-doped graphene quantum dots (amine-N-GQDs) and further characterized experimentally by different analytical techniques. The molecular simulation studies were performed using the Material Studio software for optimizing the possible chemical structure of synthesized amine-N-GQDs, a comprehensive analysis of experimental results to validate the presence of potential N-doping and amine functionalization sites. Then monoclonal neuron-specific enolase antibodies (anti-NSE) were covalently immobilized to amine-N-GQDs to provide the biofunctionalized GQDs (anti-NSE/amine-N-GQDs). A label-free and efficient fluorescent biosensor based on nanosurface energy transfer (NSET) between anti-NSE/amine-N-GQDs and AuNPs has been developed for neuron-specific enolase (NSE) detection. The fluorescence response studies of anti-NSE/amine-N-GQDs@AuNPs nanoprobe conducted as a function of NSE antigen exhibited fast response time (16 min), broader linear detection range (0.1 pg mL(-1) to 1000 ng mL(-1)), and remarkably low detection limit (0.09 pg mL(-1)).
引用
收藏
页码:4922 / 4932
页数:11
相关论文
共 58 条
[1]   An electrochemical immunosensor based on poly p-phenylenediamine and graphene nanocomposite for detection of neuron-specific enolase via electrochemically amplified detection [J].
Amani, Jafar ;
Maleki, Mehdi ;
Khoshroo, Alireza ;
Sobhani-Nasab, Ali ;
Rahimi-Nasrabadi, Mehdi .
ANALYTICAL BIOCHEMISTRY, 2018, 548 :53-59
[2]  
[Anonymous], 2020, MAT STUDIO
[3]   Lung Cancer and Its Early Detection Using Biomarker-Based Biosensors [J].
Arya, Sunil K. ;
Bhansali, Shekhar .
CHEMICAL REVIEWS, 2011, 111 (11) :6783-6809
[4]   Amine-Functionalized MoO3@RGO Nanohybrid-Based Biosensor for Breast Cancer Detection [J].
Augustine, Shine ;
Kumar, Pragati ;
Malhotra, Bansi D. .
ACS APPLIED BIO MATERIALS, 2019, 2 (12) :5366-5378
[5]   Chemical modifications and bioconjugate reactions of nanomaterials for sensing, imaging, drug delivery and therapy [J].
Biju, Vasudevanpillai .
CHEMICAL SOCIETY REVIEWS, 2014, 43 (03) :744-764
[6]   Delivering quantum dots to cells: bioconjugated quantum dots for targeted and nonspecific extracellular and intracellular imaging [J].
Biju, Vasudevanpillai ;
Itoh, Tamitake ;
Ishikawa, Mitsuru .
CHEMICAL SOCIETY REVIEWS, 2010, 39 (08) :3031-3056
[7]   Resonance energy transfer to gold nanoparticles: NSET defeats FRET [J].
Chen, Chi ;
Hildebrandt, Niko .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 123
[8]   Nanosurface Energy Transfer from Long-Lifetime Terbium Donors to Gold Nanoparticles [J].
Chen, Chi ;
Midelet, Clyde ;
Bhuckory, Shashi ;
Hildebrandt, Niko ;
Werts, Martinus H. V. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2018, 122 (30) :17566-17574
[9]   Cancer biomarker determination by resonance energy transfer using functional fluorescent nanoprobes [J].
Das, Pradip ;
Sedighi, Abootaleb ;
Krull, Ulrich J. .
ANALYTICA CHIMICA ACTA, 2018, 1041 :1-24
[10]   Biosensor for Point-of-Care Analysis of Immunoglobulins in Urine by Metal Enhanced Fluorescence from Gold Nanoparticles [J].
Della Ventura, Bartolomeo ;
Gelzo, Monica ;
Battista, Edmondo ;
Alabastri, Alessandro ;
Schirato, Andrea ;
Castaldo, Giuseppe ;
Corso, Gaetano ;
Gentile, Francesco ;
Velotta, Raffaele .
ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (04) :3753-3762