Measurement of the broadband complex permittivity of soils in the frequency domain with a low-cost Vector Network Analyzer and an Open-Ended coaxial probe

被引:23
作者
Gonzalez-Teruel, Juan D. [1 ]
Jones, Scott B. [2 ]
Robinson, David A. [2 ,3 ]
Gimenez-Gallego, Jaime [1 ]
Zornoza, Raill [4 ]
Torres-Sanchez, Roque [1 ]
机构
[1] Tech Univ Cartagena, Dept Automat Elect Engn & Elect Technol, Cartagena, Spain
[2] Utah State Univ, Dept Plants Soils & Climate, Logan, UT 84322 USA
[3] ECW, UK Ctr Ecol & Hydrol, Bangor LL57 2UW, Gwynedd, Wales
[4] Tech Univ Cartagena, Dept Agr Engn, Cartagena 30203, Spain
基金
英国自然环境研究理事会;
关键词
Complex permittivity; Soil spectroscopy; Frequency Domain Reflectometry; Soil moisture; Open-ended coaxial probe; nanoVNA; Low-cost instrument; Vector Network Analyzer; Dielectric dispersion; DIELECTRIC-PROPERTIES; WATER CONTENT; LINE; REFLECTOMETRY; MODEL;
D O I
10.1016/j.compag.2022.106847
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The performance of a handheld Vector Network Analyzer (VNA), the nanoVNA, a low-cost, open-source instrument, was evaluated. The instrument measures the complex permittivity of dielectric media from 1-port reflection parameters in the 1 - 900 MHz bandwidth. We manufactured an open-ended coaxial probe using a SMA-N coaxial adapter to perform dielectric measurements. The accuracy of the nanoVNA was comparable to that of a commercial VNA between 1 and 500 MHz according to tests in reference organic liquids, while a lack of stability was found beyond 700 MHz. The self-manufactured open-ended coaxial probe was subjected to a Finite Element Method (FEM) analysis and its electromagnetic (EM) field penetration depth was determined to be 1.5 mm at 100 MHz, being reduced to 1.3 at 900 MHz and thus demonstrating a frequency-dependent support volume. The broadband complex permittivity of three mineral soils of varied textures was obtained for a range of bulk densities and water contents from dry to water-saturated conditions. The dielectric response of the soils approximated the well-known Topp et al. (1980) equation at high frequencies. At lower frequency however, higher permittivities were exhibited due to dielectric dispersion, which emphasizes the importance of EM-based soil moisture sensor operating frequency when considering sensor calibration or comparing the response of different sensors.
引用
收藏
页数:11
相关论文
共 41 条
[1]  
Anjos L., 2015, WORLD REFERENCE BASE
[2]  
ASTM, 2018, ASTM D1193-06, DOI [DOI 10.1520/D1193-06R18, 10.1520/D1193-06R18]
[3]   A New Broadband Dielectric Model for Simultaneous Determination of Water Saturation and Porosity [J].
Bore, Thierry ;
Schwing, Moritz ;
Serna, Marcelo Llano ;
Speer, Jennifer ;
Scheuermann, Alexander ;
Wagner, Norman .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2018, 56 (08) :4702-4713
[4]  
Buckley F., 1958, Circular Bureau Stan-dards 589: Tables Dielectric Dispersion Data for Pure LiquidsDilute Solutions
[5]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[6]  
Cross J.D., 2014, Low-Frequency Electromagnetic Fields for the Detection of Buried Objects in the Shallow Sub-Surface
[7]   TIME-DOMAIN REFLECTOMETRY - SIMULTANEOUS MEASUREMENT OF SOIL-WATER CONTENT AND ELECTRICAL-CONDUCTIVITY WITH A SINGLE PROBE [J].
DALTON, FN ;
HERKELRATH, WN ;
RAWLINS, DS ;
RHOADES, JD .
SCIENCE, 1984, 224 (4652) :989-990
[8]  
Davis J.L., 1975, GEOL SURV CAN, V75-1, P75, DOI DOI 10.4095/104349
[9]  
Debye P., 1929, Polar Molecules
[10]  
Demontoux F., 2021, LOW COST DIELECTRIC, DOI [10.1109/IGARSS47720.2021.9554253, DOI 10.1109/IGARSS47720.2021.9554253]