Real-Time Augmented Reality for Ear Surgery

被引:10
作者
Hussain, Raabid [1 ]
Lalande, Alain [1 ]
Marroquin, Roberto [1 ]
Girum, Kibrom Berihu [1 ]
Guigou, Caroline [2 ]
Grayeli, Alexis Bozorg [1 ,2 ]
机构
[1] Univ Bourgogne Franche Comte, Le2i, Dijon, France
[2] Univ Hosp Dijon, ENT Dept, Dijon, France
来源
MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT IV | 2018年 / 11073卷
关键词
Augmented reality; Transtympanic procedures; Otology; Minimally invasive; Image-guided surgery; REGISTRATION;
D O I
10.1007/978-3-030-00937-3_38
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Transtympanic procedures aim at accessing the middle ear structures through a puncture in the tympanic membrane. They require visualization of middle ear structures behind the eardrum. Up to now, this is provided by an oto endoscope. This work focused on implementing a real-time augmented reality based system for robotic-assisted transtympanic surgery. A preoperative computed tomography scan is combined with the surgical video of the tympanic membrane in order to visualize the ossciles and labyrinthine windows which are concealed behind the opaque tympanic membrane. The study was conducted on 5 artificial and 4 cadaveric temporal bones. Initially, a homography framework based on fiducials (6 stainless steel markers on the periphery of the tympanic membrane) was used to register a 3D reconstructed computed tomography image to the video images. Micro/endoscope movements were then tracked using Speeded-Up Robust Features. Simultaneously, a micro-surgical instrument (needle) in the frame was identified and tracked using a Kalman filter. Its 3D pose was also computed using a 3-collinear-point framework. An average initial registration accuracy of 0.21mm was achieved with a slow propagation error during the 2-minute tracking. Similarly, a mean surgical instrument tip 3D pose estimation error of 0.33mm was observed. This system is a crucial first step towards keyhole surgical approach to middle and inner ears.
引用
收藏
页码:324 / 331
页数:8
相关论文
共 18 条
[1]   Toward Detection and Localization of Instruments in Minimally Invasive Surgery [J].
Allan, Max ;
Ourselin, Sebastien ;
Thompson, Steve ;
Hawkes, David J. ;
Kelly, John ;
Stoyanov, Danail .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) :1050-1058
[2]  
[Anonymous], 2003, Multiple view geometry in computer vision
[3]   Speeded-Up Robust Features (SURF) [J].
Bay, Herbert ;
Ess, Andreas ;
Tuytelaars, Tinne ;
Van Gool, Luc .
COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 110 (03) :346-359
[4]   Eustachian Tube Dilation via a Transtympanic Approach in 6 Cadaver Heads: A Feasibility Study [J].
Dean, Marc ;
Chao, Wei-Chieh ;
Poe, Dennis .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (04) :654-656
[5]  
Gurr A., 2006, MIDDLE EAR SURG, P19, DOI [DOI 10.1007/978-3-540-47671-9_6, 10.1007/978-3-540-47671-9_6]
[6]  
Haase S, 2013, IEEE WORK APP COMP, P449, DOI 10.1109/WACV.2013.6475053
[7]   2D/3D registration of endoscopic ultrasound to CT volume data [J].
Hummel, Johann ;
Figl, Michael ;
Bax, Michael ;
Bergmann, Helmar ;
Birkfellner, Wolfgang .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (16) :4303-4316
[8]   A portable 3D vision coordinate measurement system using a light pen [J].
Liu, SG ;
Peng, K ;
Huang, FS ;
Zhang, GX ;
Li, P .
MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 :331-336
[9]   Augmented Reality of the Middle Ear Combining Otoendoscopy and Temporal Bone Computed Tomography [J].
Marroquin, Roberto ;
Lalande, Alain ;
Hussain, Raabid ;
Guigou, Caroline ;
Grayeli, Alexis Bozorg .
OTOLOGY & NEUROTOLOGY, 2018, 39 (08) :931-939
[10]   Use of a Microendoscope for Transtympanic Drug Delivery to the Round Window Membrane in Chinchillas [J].
Mood, Zhoobin A. ;
Daniel, Sam J. .
OTOLOGY & NEUROTOLOGY, 2012, 33 (08) :1292-1296