Quantitative in vitro comparison of fluorescein delivery to the eye via impregnated paper strip and volumetric techniques

被引:13
作者
Abdul-Fattah, AM
Bhargava, HN
Korb, DR
Glonek, T
Finnemore, VM
Greiner, JV
机构
[1] Harvard Univ, Sch Med, Dept Ophthalmol, Schepens Eye Res Inst, Boston, MA 02114 USA
[2] Massachusetts Coll Pharm & Hlth Sci, Div Pharmaceut Sci, Boston, MA USA
[3] Ocular Res Boston Inc, Boston, MA USA
[4] Midwestern Univ, MR Lab, Chicago, IL USA
关键词
fluorescein; fluorescein sodium-impregnated paper strips; fluorescein break-up time; tear film; dry eye;
D O I
10.1097/00006324-200207000-00012
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the quantity of fluorescein delivered to the eye via fluorescein-impregnated paper strips of various sizes and surface areas and via various microliter volumes of fluorescein sodium using an in vitro assay. Methods. A commercially available fluorescein-impregnated strip (75 mm(2)) and three modified strips of reduced fluorescein-impregnated surface areas (10, 7.5, and 5.0 mm(2)) were used. The amount of fluorescein delivered to the eye for each of the four strips was approximated by applying each strip to a Whatman No. 1 filter paper under conditions simulating application of the strip to the eye, extracting the fluorescein from the filter paper in an aqueous solution, and performing spectrophotometric analysis at 484 nm. Similarly, this filter paper analytical system was calibrated using 1, 2, and 3 mul volumes of 2% w/v fluorescein delivered to the filter paper. Results. Using calibration curves, linearity was observed between absorbance and concentration of fluorescein sodium with an R-2 value greater than or equal to0.99. Using these calibration curves, the amount of fluorescein delivered to the eye for the four strips and the three fluorescein solution samples was determined. Fluorescein-impregnated strips with surface areas of 75, 10, and 5 mm(2) delivered approximately the same quantity of fluorescein to the ocular surface as 3 mul, 1 mul, and 0.5 mul of fluorescein 2% solution, respectively. Conclusions. The surface area of the fluorescein-impregnated portion of the strip can be designed to control the amount of fluorescein delivered to the eye.
引用
收藏
页码:435 / 438
页数:4
相关论文
共 13 条
[1]  
FEENSTRA RPG, 1992, OPHTHALMOLOGY, V99, P605
[2]  
Finnemore VM, 1998, ADV EXP MED BIOL, V438, P875
[3]  
LARKE JR, 1997, EYE CONTACT LENS WEA, P32
[4]  
LEMP MA, 1973, ARCH OPHTHALMOL-CHIC, V89, P103
[5]  
Lemp Michael A., 1995, CLAO Journal, V21, P221
[6]  
LOWTHER GE, 1997, DRYNESS TEARS CONTAC, P36
[7]  
Marquardt R, 1986, PREOCULAR TEAR FILM, P57
[8]   A NON-INVASIVE INSTRUMENT FOR CLINICAL-ASSESSMENT OF THE PRE-CORNEAL TEAR FILM STABILITY [J].
MENGHER, LS ;
BRON, AJ ;
TONGE, SR ;
GILBERT, DJ .
CURRENT EYE RESEARCH, 1985, 4 (01) :1-7
[9]  
MISHIMA S., 1966, INVEST OPHTHALMOL, V5, P264
[10]   DIAGNOSIS OF KERATOCONJUNCTIVITIS SICCA [J].
NELSON, JD .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1994, 34 (01) :37-56