Comparison of virtual non-contrast dual-energy CT and a true non-contrast CT for contouring in radiotherapy of 3D printed lung tumour models in motion: a phantom study

被引:4
作者
Hering, Dominik Alexander [1 ]
Kroger, Kai [1 ]
Bauer, Ralf W. [2 ]
Eich, Hans Theodor [1 ]
Haverkamp, Uwe [1 ]
机构
[1] Univ Hosp Muenster, Dept Radiat Oncol, Munster, Germany
[2] RNS, Private Radiol & Radiat Therapy Grp, Wiesbaden, Germany
关键词
BREATH-HOLD RADIOTHERAPY; COMPUTED-TOMOGRAPHY; IODINE QUANTIFICATION; MONOENERGETIC-EXTRAPOLATION; ELECTRON-DENSITY; SIMULATION; IMPACT;
D O I
10.1259/bjr.20200152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: This work aims to investigate whether virtual non-contrast (VNC) dual-energy CT(DECT) of contrasted lung tumours can be used as an alternative for true non-contrast (TNC) images in radiotherapy. Two DECT techniques and a TNC CT were compared and influences on gross tumour volume (GTV) volume and CT number from motion artefacts in three-dimensional printed lung tumour models (LTM) in amotion phantom were examined. Methods: Two spherical LTMs (diameter 3.0cm) with different inner shapes were created in a threedimensional printer. The inner shapes contained water or iodine (concentration 5 mg ml(-1)) and were scanned with a dual-source DECT (ds-DECT), single-source sequential DECT (ss-DECT) and TNC CT in a respiratory motion phantom (15 breaths/min, amplitude 1.5cm). CT number and volume of LTMs were measured. Therefore, two GTVs were contoured. Results: Deviations in GTV volume (outer shape) of LTMs in motion for contrast-enhanced ss-DECT and ds-DECT VNC images compared to TNC images are not significant (p > 0.05). Relative GTV volume and CT number deviations (inner shapes) of LTMs in motion were 6.6 +/- 0.6% and 104.4 +/- 71.2 HU between ss-DECT and TNC CT and -8.4 +/- 10.6% and 25.5 +/- 58.5 HU between ds-DECT and TNC, respectively. Conclusion: ss-DECT VNC images could not sufficiently subtract iodine from water in LTMs inmotion, whereas ds-DECT VNC images might be a valid alternative to a TNC CT. Advances in knowledge: ds-DECT provides a contrasted image for contouring and a non-contrasted image for radiotherapy treatment planning for LTM in motion.
引用
收藏
页数:8
相关论文
共 35 条
[11]   Differentiation of Lung Cancers From Inflammatory Masses with Dual-Energy Spectral CT Imaging [J].
Hou, Wei Shu ;
Wu, Hua Wei ;
Yin, Yan ;
Cheng, Jie Jun ;
Zhang, Qing ;
Xu, Jian Rong .
ACADEMIC RADIOLOGY, 2015, 22 (03) :337-344
[12]   Evaluation of lung cancer by enhanced dual-energy CT: association between three-dimensional iodine concentration and tumour differentiation [J].
Iwano, Shingo ;
Ito, Rintaro ;
Umakoshi, Hiroyasu ;
Ito, Shinji ;
Naganawa, Shinji .
BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1055)
[13]   Intermanufacturer Comparison of Dual-Energy CT Iodine Quantification and Monochromatic Attenuation: A Phantom Study [J].
Jacobsen, Megan C. ;
Schellingerhout, Dawid ;
Wood, Cayla A. ;
Tamm, Eric P. ;
Godoy, Myrna C. ;
Sun, Jia ;
Cody, Dianna D. .
RADIOLOGY, 2018, 287 (01) :224-234
[14]   Geometric uncertainties in voluntary deep inspiration breath hold radiotherapy for locally advanced lung cancer [J].
Josipovic, Mirjana ;
Persson, Gitte F. ;
Dueck, Jenny ;
Bangsgaard, Jens Peter ;
Westman, Gunnar ;
Specht, Lena ;
Aznar, Marianne C. .
RADIOTHERAPY AND ONCOLOGY, 2016, 118 (03) :510-514
[15]   Comparison of Iodine Density Measurement Among Dual-Energy Computed Tomography Scanners From 3 Vendors [J].
Kim, Hyungjin ;
Goo, Jin Mo ;
Kang, Chang Kyung ;
Chae, Kum Ju ;
Park, Chang Min .
INVESTIGATIVE RADIOLOGY, 2018, 53 (06) :321-327
[16]   Influence of radiation dose and iterative reconstruction algorithms for measurement accuracy and reproducibility of pulmonary nodule volumetry: A phantom study [J].
Kim, Hyungjin ;
Park, Chang Min ;
Song, Yong Sub ;
Lee, Sang Min ;
Goo, Jin Mo .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (05) :848-857
[17]  
Kriz J, 2015, STRAHLENTHER ONKOL, V191, P717, DOI 10.1007/s00066-015-0839-x
[18]   Robust quantitative contrast-enhanced dual-energy CT for radiotherapy applications [J].
Lapointe, Andreanne ;
Lalonde, Arthur ;
Bahig, Houda ;
Carrier, Jean-Francois ;
Bedwani, Stephane ;
Bouchard, Hugo .
MEDICAL PHYSICS, 2018, 45 (07) :3086-3096
[19]  
Mangold S, 2014, INVEST RADIOL, V49, P788, DOI 10.1097/RLI.0000000000000083
[20]   Quality assurance for computed-tomography simulators and the computedtomography-simulation process: Report of the AAPM radiation therapy committee task group no. 66 [J].
Mutic, S ;
Palta, JR ;
Butker, EK ;
Das, IJ ;
Huq, MS ;
Loo, LND ;
Salter, BJ ;
McCollough, CH ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (10) :2762-2792