Modified body adiposity index for body fat estimation in severe obesity

被引:15
作者
Bernhard, A. B. [1 ]
Scabim, V. M. [1 ]
Serafim, M. P. [1 ]
Gadducci, A. V. [1 ]
Santo, M. A. [1 ]
de Cleva, R. [1 ]
机构
[1] Univ Sao Paulo, Dept Gastroenterol, Fac Med, Inst Cent,Hosp Clin,Med Sch, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
bioelectrical impedance analysis; body adiposity index; body composition; severe obesity; waist-hip ratio; BIOELECTRICAL-IMPEDANCE ANALYSIS; BRAZILIAN WOMEN; WEIGHT-LOSS; MASS INDEX; OVERWEIGHT;
D O I
10.1111/jhn.12404
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
BackgroundThe body adiposity index (BAI) comprises a simple method for estimating body fat (BF) that needs to be validated in patients with severe obesity. The present study aimed to determine BAI accuracy with respect to the determination BF in patients with severe obesity. MethodsA cross-sectional prospective study comparing two methods for BF estimation was conducted in 433 patients with severe obesity between August 2012 to December 2014. BF was estimated by bioelectrical impedance analysis (BIA) with specific equations developed for BF estimation in patients with severe obesity and BAI. The BF estimation in 240 patients with severe obesity (Group 1: G1) was used to evaluate BAI limitations and to develop a specific equationin this population. The new equationproposed was validated in another 158 patients with severe obesity (Group 2: G2). ResultsThere was a significant difference between BF determination by BIA and BAI (P=0.039). The mean (SD) BF in G1 was 52.3%(6.1%) determined by BIA and 51.6%(8.1%) determined by BAI. Sex, waist-hip ratio (WHR) and obesity grade determined significant errors on BF estimation by BAI. A new equation(modified body adiposity index; MBAI) was developed by linear regression to minimise these errors [MBAI%=23.6+0.5x(BAI); add 2.2 if body mass index50kgm(-2) and 2.4 if WHR1.05]. The new equationreduced the difference [1.2% (5.9%), P<0.001 to 0.4%(4.12%), P=0.315] and improved the correlation (0.6-0.7) between methods. ConclusionsBAI present significant limitations in severe obesity and MBAI was effective for BF estimation in this population.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 31 条
[1]  
Berentzen T, 2006, NUTR REV, V64, P502, DOI [10.1111/j.1753-4887.2006.tb00183.x, 10.1301/nr.2006.nov.502507]
[2]   A Better Index of Body Adiposity [J].
Bergman, Richard N. ;
Stefanovski, Darko ;
Buchanan, Thomas A. ;
Sumner, Anne E. ;
Reynolds, James C. ;
Sebring, Nancy G. ;
Xiang, Anny H. ;
Watanabe, Richard M. .
OBESITY, 2011, 19 (05) :1083-1089
[3]   Comparison of body composition methods in overweight and obese Brazilian women [J].
Braulio, Valeria Bender ;
Soares Furtado, Valeria Cristina ;
Silveira, Maria das Gracas ;
Fonseca, Maria Helena ;
Oliveira, Jose Egidio .
ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2010, 54 (04) :398-405
[4]   Validity of body adiposity index in predicting body fat in a sample of brazilian women [J].
Cerqueira, Matheus ;
Amorim, Paulo ;
Magalhaes, Filipe ;
Castro, Eliane ;
Franco, Frederico ;
Franceschini, Sylvia ;
Cerqueira, Lizbeth ;
Marins, Joao ;
Doimo, Leonice .
OBESITY, 2013, 21 (12) :E696-E699
[5]   Body composition measurement in severe obesity [J].
Das, SK .
CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (06) :602-606
[6]  
Das SK, 2003, AM J PHYSIOL-ENDOC M, V6, P1080
[7]  
Deurenberg P, 1996, AM J CLIN NUTR, V64, P449
[8]   Relationship between the body adiposity index and cardiometabolic risk factors in obese postmenopausal women [J].
Elisha, Belinda ;
Rabasa-Lhoret, Remi ;
Messier, Virginie ;
Abdulnour, Joseph ;
Karelis, Antony D. .
EUROPEAN JOURNAL OF NUTRITION, 2013, 52 (01) :145-151
[9]  
Geliebter A., 2013, OBESITY, V21, P1, DOI [10.1002/oby.20264.Comparison, DOI 10.1002/OBY.20264.COMPARISON]
[10]  
Gibson C D, 2012, Int J Body Compos Res, V10, P9