Modelling and analysis of asymmetrical three-phase distribution transformer banks with mid-tap connected to the secondary neutral conductor

被引:19
作者
Chen, TH [1 ]
Yang, WC [1 ]
Guo, TY [1 ]
Pu, GC [1 ]
机构
[1] Natl Taiwan Univ Sci& Technol, Dept Elect Engn, Taipei, Taiwan
关键词
distribution system; phase co-ordinate model; asymmetrical three-phase transformer bank; mid-tap; network overlapping technique; unbalance;
D O I
10.1016/S0378-7796(99)00075-9
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents phase co-ordinate models for five asymmetrical three-phase distribution transformer banks with mid-tap connected to the secondary neutral conductor. On the basis of the proposed models, these three-phase transformer banks are investigated in this paper. To simplify the derivation of the proposed models, the network-overlapping technique was used. The major considerations in the derivations include copper and core losses,phase angular displacement between primary and secondary voltages, and off-nominal tapping. Using appropriate three-phase power-flow programs or commercial simulation software, the inherent characteristics of these five specific transformer banks under a steady-state condition could be correctly retrieved. The comparison of results of field tests and computer simulations have demonstrated the correctness of these proposed models. The models are of value to distribution engineers for improving the simulation accuracy of a distribution system especially under unbalanced circumstances. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 8 条
[1]  
BURKHOLDER JA, 1994, P 6 INT C TOX MAR PH, P53
[2]   DETECTION OF HIGH IMPEDANCE FAULTS ON MULTI-GROUNDED PRIMARY DISTRIBUTION-SYSTEMS [J].
CARR, J .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04) :2008-2016
[3]   NETWORK MODELING OF TRACTION SUBSTATION TRANSFORMERS FOR STUDYING UNBALANCE EFFECTS [J].
CHEN, TH ;
KUO, HY .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1995, 142 (02) :103-108
[4]   3-PHASE COGENERATOR AND TRANSFORMER MODELS FOR DISTRIBUTION-SYSTEM ANALYSIS [J].
CHEN, TH ;
CHEN, MS ;
INOUE, T ;
KOTAS, P ;
CHEBLI, EA .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (04) :1671-1681
[5]   Models of grounded mid-tap open-wye and open-delta connected transformers for rigorous analysis of a distribution system [J].
Chen, TH ;
Chang, JD ;
Chang, YL .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (01) :82-88
[6]   STABILITY MARGINS OF SINGULARLY PERTURBED DISCRETE-TIME-SYSTEMS BASED ON STATE FEEDBACK AND LINEAR QUADRATIC OPTIMAL-CONTROL [J].
CHENG, CP ;
LI, THS ;
SUN, YY .
OPTIMAL CONTROL APPLICATIONS & METHODS, 1992, 13 (03) :227-245
[7]  
GONEN T, 1986, ELECT POWER DISTRIBU, P146
[8]   Modeling and analysis of unsymmetrical transformer banks serving unbalanced loads [J].
Kersting, WH ;
Phillips, WH .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (03) :720-725