Traceable Determination of the Absolute Neutron Emission Yields of UO2F2 Working Reference Materials

被引:2
作者
LaFleur, Adrienne M. [1 ]
Croft, Stephen [2 ]
Mayer, Richard L. [3 ]
Swinhoe, Martyn T. [1 ]
Mayo, Douglas R. [1 ]
Sapp, Benjamin A. [1 ]
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[3] DOE Portsmouth Paducah Project Off, Piketon, OH 45661 USA
关键词
Holdup; nondestructive assay; nuclear safeguards; uranium enrichment;
D O I
10.1109/TNS.2013.2284435
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The nuclear material contained in the process equipment of a uranium enrichment plant (referred to as holdup) is an important component of the overall nuclear material inventory for the plant. Accurate quantification and verification of holdup is needed to improve international safeguards and nuclear material accountancy. This is also needed for criticality safety and waste disposition. Passive neutron and gamma-ray nondestructive assay (NDA) methods are used to measure the holdup in process equipment. A key advantage of neutron measurements is that neutrons are highly penetrating and can be measured through thick walled equipment. The dominant source of neutrons in the UO2F2 holdup is from the F-19(alpha,n)Na-22 reaction resulting from U-234 alpha decay when uranium is enriched. There is a considerable spread between different historic determinations of the F-19(alpha,n) yield from uranium which limits the accuracy of modeling and the calibration of NDA instruments. Furthermore, the compound form and presence of water also significantly affects the neutron emission rate from the holdup. This paper describes a series of experimental measurements performed at Los Alamos National Laboratory (LANL) to determine the absolute neutron emission yield from 10 different UO2F2 working reference materials (WRMs) fabricated at the Portsmouth Gaseous Diffusion Plant (PGDP). The Mini Epithermal Neutron Multiplicity Counter (Mini ENMC) and a NIST certified neutron source were used for these measurements. The high efficiency and short die-away time of the Mini ENMC provides the high measurement precision needed to certify the neutron emission yield. The experiment was designed to achieve sub 1% accuracy in the net counting rate on each item and to provide assurance that important factors such as instrument stability, item placement and background were well understood. The traceable neutron yields measured from the WRMs were used to determine a more accurate neutron yield for the UO2F2 material. The results were compared to historical neutron emission rates. The F(alpha,n) data obtained from these measurements directly supports nuclear safeguards for NDA of uranium holdup and provides a more accurate calibration for new and existing NDA detector systems.
引用
收藏
页码:2182 / 2188
页数:7
相关论文
共 23 条
[1]  
Alvarez E., 2006, P WAST MAN S TUCS AZ
[2]  
[Anonymous], POEF83611108 US ENR
[3]  
[Anonymous], COMMUNICATION
[4]  
[Anonymous], 1996, 846255873951 US DEP
[5]   NEUTRON YIELDS FROM ALPHA-PARTICLE BOMBARDMENT [J].
BAIR, JK ;
GOMEZDELCAMPO, J .
NUCLEAR SCIENCE AND ENGINEERING, 1979, 71 (01) :18-28
[6]   STUDY OF REACTION F-19(ALPHA, N)NA-22 IN BOMBARDING ENERGY-RANGE 2.6 TO 5.1 MEV [J].
BALAKRISHNAN, M ;
KAILAS, S ;
MEHTA, MK .
PRAMANA, 1978, 10 (03) :329-339
[7]  
Berger M., 2005, STOPPING POWER RANGE
[8]   How the choice of data reduction can strongly influence uncertainty assessment: A re-analysis of Mn-bath experiments [J].
Croft, S. ;
Favalli, A. .
RADIATION MEASUREMENTS, 2012, 47 (07) :481-485
[9]   The specific total and coincidence cosmic-ray-induced neutron production rates in materials [J].
Croft, S ;
Bourva, LCA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2) :536-539
[10]  
Croft S., 2003, P 25 ANN ESARDA M