Method optimization for the determination of four mercury species by micro-liquid chromatography-inductively coupled plasma mass spectrometry coupling in environmental water samples

被引:49
作者
Castillo, A. [1 ]
Roig-Navarro, A. F. [1 ]
Pozo, O. J. [1 ]
机构
[1] Univ Jaume 1, Res Inst Pesticides & Water, E-12071 Castellon de La Plana, Spain
关键词
mercury speciation; microbore column; micro-liquid chromatography; micronebulizer; inductively coupled plasma mass spectrometry; water;
D O I
10.1016/j.aca.2006.06.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method based on the coupling microHPLC-microneb-ICPMS has been developed for Hg(II), MeHg+, EtHg+ and PhHg+ species. Gradient elution using methanol and L-cysteine at pH 3.0 allowed the chromatographic separation of all species in less than 13 min (total analysis time 15 min). The direct coupling of microLC to ICPMS through a Micromist nebulizer permits the analysis of environmental water without sample pretreatment and derivatization steps. Nebulizer type, organic modifier and column length were the main parameters tested. The methanol content and pH of the mobile phase greatly affected the retention time and sensitivity of the method. Key factors to obtain high signal to noise ratio, at concentrations below 1 mu g L-1, were found to be the nebulization step and traces of Hg present in the complexing agent. A detailed optimization of carrier and make up gas flow rates have enabled the nebulization of the methanol gradient elution with good mass transport efficiency, low organic solvent loading into the plasma and excellent precision. The performance of the microHPLC-microneb-ICPMS method developed was evaluated on a surface water sample filtered (0.22 mu m) and spiked with 0.5 mu g L-1 (as Hg) of each species. Precision (R.S.D., n=6) for all species of Hg varied from 0.5 to 2.1%. Detection limit, defined as three times the standard deviation (n = 6), ranged from 8 ng L-1 for EtHg+ to 32 ng L-1 for PhHg+ and was noticeably lower than those reported in previous LC-based methods. Accuracy was suitable with recoveries ranging from 85 to 100% when tested at two levels (0.5 and 10 mu g L-1) in groundwater samples. Recovery was matrix affected when water samples of high salinity (depurated wastewater and seawater) were used. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 25 条
[1]   A comparison of nebulizers for microbore LC-ICP-MS with mobile phases containing methanol [J].
Ackley, KL ;
Sutton, KL ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1069-1073
[2]   Determination of mercury species in sea-water by liquid chromatography with inductively coupled plasma mass spectrometric detection [J].
Bloxham, MJ ;
Gachanja, A ;
Hill, SJ ;
Worsfold, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (02) :145-148
[3]   Mercury speciation by liquid chromatography coupled with on-line chemical vapour generation and atomic fluorescence spectrometric detection (LC-CVGAFS) [J].
Bramanti, E ;
Lomonte, C ;
Onor, M ;
Zamboni, R ;
D'Ulivo, A ;
Raspi, G .
TALANTA, 2005, 66 (03) :762-768
[4]   Mercury speciation analysis in sea water by solid phase microextraction-gas chromatography-inductively coupled plasma mass spectrometry using ethyl and propyl derivatization.: Matrix effects evaluation [J].
Bravo-Sánchez, LR ;
Encinar, JR ;
Martínez, JIF ;
Sanz-Medel, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (01) :59-66
[5]   Multielemental speciation analysis of organometallic compounds of mercury, lead and tin in natural water samples by headspace-solid phase microextraction followed by gas chromatography-mass spectrometry [J].
Centineo, G ;
González, EB ;
Sanz-Medel, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1034 (1-2) :191-197
[6]   On-line coupling of flow injection displacement sorption preconcentration to high-performance liquid chromatography for speciation analysis of mercury in seafood [J].
Dong, LM ;
Yan, XP ;
Li, Y ;
Jiang, Y ;
Wang, SW ;
Jiang, DQ .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1036 (02) :119-125
[7]  
Garraud H, 1997, ANALUSIS, V25, P25
[8]   Analytical approach for routine methylmercury determination in seafood using gas chromatography-atomic fluorescence spectrometry [J].
Gómez-Ariza, JL ;
Lorenzo, F ;
García-Barrera, T ;
Sánchez-Rodas, D .
ANALYTICA CHIMICA ACTA, 2004, 511 (01) :165-173
[9]   The speciation of mercury and organomercury compounds by using high-performance liquid chromatography [J].
Harrington, CF .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (2-3) :167-179
[10]   DETERMINATION OF INORGANIC HG(II) AND ORGANIC MERCURY-COMPOUNDS BY ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HO, YS ;
UDEN, PC .
JOURNAL OF CHROMATOGRAPHY A, 1994, 688 (1-2) :107-116