The effect of tinted soft contact lens wear on functional visual acuity and higher-order aberrations

被引:7
作者
Watanabe, Kazuhiro [1 ]
Kaido, Minako [1 ]
Ishida, Reiko [1 ]
Dogru, Murat [1 ,2 ]
Negishi, Kazuno [1 ]
Tsubota, Kazuo [1 ]
机构
[1] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
[2] Ichikawa Hosp, Tokyo Dent Coll, Dept Ophthalmol, Chiba, Japan
关键词
Tinted soft contact lens; Functional visual acuity; Higher order aberration; STEVENS-JOHNSON-SYNDROME; DRY EYE PATIENTS; PERFORMANCE; KERATITIS; CATARACT; SYSTEM;
D O I
10.1016/j.clae.2013.11.009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the differences of functional visual acuity (FVA) and high order aberrations (HOAs) in relation to tinted and clear hydrogel soft contact lens (SCL) wear. Methods: A prospective comparative study was performed in 16 eyes of 16 healthy volunteers. Dynamic visual acuity (using a FVA measurement system) and higher-order aberrations (using a wavefront sensor) were compared in subjects wearing two types of soft contact lenses: 1-day Acuvue (R) (Vistakon, Jacksonville, FL) clear and the 1-day Acuvue (R) Define (TM) (Vistakon, Jacksonville, FL) tinted lens. The blink rates were recorded during FVA testing. The correlation between the difference of HOAs and differences in FVA values was analyzed. Results: The mean LogMAR FVA scores with clear and tinted SCLs were 0.07 +/- 0.13 and 0.14 +/- 0.17 (P < 0.05): The mean blink frequencies with clear and tinted SCL wear were 18.4 +/- 8.3 and 25.3 +/- 4.7 blinks/min (P < 0.05). Both 3rd-order aberrations and total HOAs showed statistically significant differences between the two types of soft contact lenses for 6 mm pupil measurements (P < 0.05). A significant positive linear correlation was observed between Delta HOAs and Delta LogMAR FVA for 6 mm pupil measurements (R = 0.53, P = 0.04). Conclusions: Tinted contact lens wear appears to induce a reduction in optical quality. Functional visual acuity measurement is a useful procedure to study the changes of visual performance and quality in tinted contact lens wear. (C) 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 36 条
  • [1] [Anonymous], [No title captured]
  • [2] Bucci Frank A. Jr., 1997, CLAO Journal, V23, P161
  • [3] Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens
    Diego, CA
    Montés-Micó, R
    Pons, AM
    Artigas, JM
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2001, 21 (05) : 411 - 419
  • [4] Dumbleton K., 2003, EYE CONTACT LENS, V29, pS90
  • [5] Dumbleton Kathy, 2003, Eye Contact Lens, V29, pS186
  • [6] Dutta D, 2012, MOL VIS, V18, P14
  • [7] Gauthier C A, 1992, J Am Optom Assoc, V63, P344
  • [8] Impaired functional visual acuity of dry eye patients
    Goto, E
    Yagi, Y
    Matsumoto, Y
    Tsubota, K
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (02) : 181 - 186
  • [9] Influence of cosmetically tinted soft contact lenses on higher-order wavefront aberrations and visual performance
    Hiraoka, Takahiro
    Ishii, Yuko
    Okamoto, Fumiki
    Oshika, Tetsuro
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (02) : 225 - 233
  • [10] Hong Sojin, 2010, Korean J Ophthalmol, V24, P367, DOI 10.3341/kjo.2010.24.6.367