Time-Optimal Design for Multidimensional and Parallel Transmit Variable-Rate Selective Excitation

被引:30
|
作者
Lee, Daeho [1 ]
Lustig, Michael [1 ]
Grissom, William A. [1 ]
Pauly, John M. [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
关键词
RF excitation; VERSE; time-optimal; multidimensional; parallel; SAR; RF PULSE DESIGN; GRADIENT WAVE-FORMS; SPIN-ECHO; OPTIMIZATION; ALGORITHM;
D O I
10.1002/mrm.21950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Variable-rate selective excitation (VERSE) is a radio frequency (RF) pulse reshaping technique. It is most commonly used to reduce the peak magnitude and specific absorption rate (SAR) of RF pulses by reshaping pulses and gradient waveforms to reduce RF magnitude while preserving excitation profiles. In this work, a general time-optimal VERSE algorithm for multidimensional and parallel transmit pulses is presented. Time optimality is achieved by translating peak RF limits to gradient upper bounds in excitation k-space. The limits are fed into a time-optimal gradient waveform design technique. Effective SAR reduction is achieved by reducing peak RF subject to a fixed pulse length. The presented method is different from other VERSE techniques in that it provides a noniterative time-optimal multidimensional solution, which drastically simplifies VERSE designs. Examples are given for 1D and 2D single channel and 2D parallel transmit pulses. Magn Reson Med 61:1471-1479, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1471 / 1479
页数:9
相关论文
共 28 条
  • [21] z Development of real-time laser-scanning system to detect tree canopy characteristics for variable-rate pesticide application
    Cai Jichen
    Wang Xiu
    Song Jian
    Wang Songlin
    Yang Shuo
    Zhao Chunjiang
    INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING, 2017, 10 (06) : 155 - 163
  • [22] Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design
    Deniz, Cem Murat
    Alon, Leeor
    Brown, Ryan
    Sodickson, Daniel K.
    Zhu, Yudong
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) : 164 - 174
  • [23] Extending slice coverage for breathhold fat-suppressed T2-weighted liver at 3.OT: Application,past spin-echo of the of variable-rate selective-excitation (VERSE) RF pulses
    van den Bos, Indra C.
    Hussain, Shahid M.
    Krestin, Gabriel P.
    Wielopolski, Piotr A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (01) : 110 - 116
  • [24] Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems
    Sbrizzi, Alessandro
    Hoogduin, Hans
    Lagendijk, Jan J.
    Luijten, Peter
    Sleijpen, Gerard L. G.
    van den Berg, Cornelis A. T.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 824 - 834
  • [25] Quick Reduction of Specific Absorption Rate Constraints in Parallel RF Excitation Pulse Design by Maximum Volume Inscribed Ellipsoids
    Majewski, Kurt
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2019, 2019
  • [26] Real-time 2D spatially selective MRI experiments: Comparative analysis of optimal control design methods
    Maximov, Ivan I.
    Vinding, Mads S.
    Tse, Desmond H. Y.
    Nielsen, Niels Chr.
    Shah, N. Jon
    JOURNAL OF MAGNETIC RESONANCE, 2015, 254 : 110 - 120
  • [27] Seven-Tesla Time-of-Flight Angiography Using a 16-Channel Parallel Transmit System With Power-Constrained 3-dimensional Spoke Radiofrequency Pulse Design
    Schmitter, Sebastian
    Wu, Xiaoping
    Auerbach, Edward J.
    Adriany, Gregor
    Pfeuffer, Josef
    Hamm, Michael
    Ugurbil, Kamil
    van de Moortele, Pierre-Francois
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 314 - 325
  • [28] Stable and quadratic-optimal parallel-distributed-compensation controller design for time-varying Takagi-Sugeno fuzzy model System: A complementary computational approach
    Chou, Fu-, I