Time-Optimal Design for Multidimensional and Parallel Transmit Variable-Rate Selective Excitation

被引:30
|
作者
Lee, Daeho [1 ]
Lustig, Michael [1 ]
Grissom, William A. [1 ]
Pauly, John M. [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
关键词
RF excitation; VERSE; time-optimal; multidimensional; parallel; SAR; RF PULSE DESIGN; GRADIENT WAVE-FORMS; SPIN-ECHO; OPTIMIZATION; ALGORITHM;
D O I
10.1002/mrm.21950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Variable-rate selective excitation (VERSE) is a radio frequency (RF) pulse reshaping technique. It is most commonly used to reduce the peak magnitude and specific absorption rate (SAR) of RF pulses by reshaping pulses and gradient waveforms to reduce RF magnitude while preserving excitation profiles. In this work, a general time-optimal VERSE algorithm for multidimensional and parallel transmit pulses is presented. Time optimality is achieved by translating peak RF limits to gradient upper bounds in excitation k-space. The limits are fed into a time-optimal gradient waveform design technique. Effective SAR reduction is achieved by reducing peak RF subject to a fixed pulse length. The presented method is different from other VERSE techniques in that it provides a noniterative time-optimal multidimensional solution, which drastically simplifies VERSE designs. Examples are given for 1D and 2D single channel and 2D parallel transmit pulses. Magn Reson Med 61:1471-1479, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1471 / 1479
页数:9
相关论文
共 28 条
  • [1] Variable-rate selective excitation for rapid MRI sequences
    Hargreaves, BA
    Cunningham, CH
    Nishimura, DG
    Conolly, SM
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 590 - 597
  • [2] Application of Variable-Rate Selective Excitation Pulses for Spin Labeling in Perfusion MRI
    He, Jiabao
    Blamire, Andrew M.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) : 842 - 847
  • [3] A TIME-OPTIMAL PARALLEL ALGORITHM FOR 3-DIMENSIONAL CONVEX HULLS
    AMATO, NM
    PREPARATA, FP
    ALGORITHMICA, 1995, 14 (02) : 169 - 182
  • [4] Using variable-rate selective excitation (VERSE) radiofrequency pulses to reduce power deposition in pulsed arterial spin labeling sequence at 7 Tesla
    Serrai, Hacene
    Buch, Sagar
    Oran, Omer
    Menon, Ravi S.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 645 - 652
  • [5] Two-dimensional radial sodium heart MRI using variable-rate selective excitation and retrospective electrocardiogram gating with golden angle increments
    Konstandin, Simon
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (03) : 791 - 799
  • [6] A time-optimal wellbore trajectory design for slide drilling systems
    Zhong, Xiao-Yu
    Liu, Jia-Peng
    Chen, Kai-Dong
    Chen, Jia-Qi
    Wang, Ning-Yu
    He, Chun-Wang
    Lu, Qiu-Hai
    Cheng, Zai-Bin
    Huang, Wen-Jun
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2021, 63 (02) : 881 - 896
  • [7] Time-optimal trajectory planning for a race car considering variable tyre-road friction coefficients
    Christ, Fabian
    Wischnewski, Alexander
    Heilmeier, Alexander
    Lohmann, Boris
    VEHICLE SYSTEM DYNAMICS, 2021, 59 (04) : 588 - 612
  • [8] Time-optimal trajectory generation of a fast-motion planar parallel manipulator
    Liu, Yanjie
    Wang, Chenqi
    Li, Juan
    Sun, Lining
    2006 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-12, 2006, : 754 - +
  • [9] DEVELOPMENT OF THE TRI-LEVEL VARIABLE-RATE TRAJECTORY WITH DISCRETELY VANISHING SHOCK FOR OPTIMUM DESIGN
    KRAMER, SN
    CURRAN, RL
    JOURNAL OF MECHANISMS TRANSMISSIONS AND AUTOMATION IN DESIGN-TRANSACTIONS OF THE ASME, 1988, 110 (01): : 88 - 92
  • [10] Fast and Robust Design of Time-Optimal k-Space Trajectories in MRI
    Davids, Mathias
    Ruttorf, Michaela
    Zoellner, Frank G.
    Schad, Lothar R.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 564 - 577