Near-infrared spectroscopic determination of human serum albumin, γ-globulin, and glucose in a control serum solution with searching combination moving window partial least squares

被引:78
作者
Kasemsumran, S
Du, YP
Murayama, K
Huehne, M
Ozaki, Y [1 ]
机构
[1] Kwansei Gakuin Univ, Sch Sci & Technol, Dept Chem, Sanda 6691337, Japan
[2] Kwansei Gakuin Univ, Sch Sci & Technol, Res Ctr Near Infrared Spect, Sanda 6691337, Japan
[3] Gifu Univ, Sch Med, Dept Biochem & Biophys, Gifu 5008705, Japan
关键词
near-infrared spectroscopy (NIR); human serum albumin (HSA); gamma-globulin; glucose; searching combination moving window partial least squares (SCMWPLS); moving window partial least squares regression (MWPLSR); quantitative analysis;
D O I
10.1016/j.aca.2004.02.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Near-infrared (NIR) spectra in the region of 5000-4000 cm(-1) with a chemometric method called searching combination moving window partial least squares (SCMWPLS) were employed to determine the concentrations of human serum albumin (HSA), gamma-globulin, and glucose contained in the control serum IIB (CS IIB) solutions with various concentrations. SCMWPLS is proposed to search for the optimized combinations of informative regions, which are spectral intervals, considered containing useful information for building partial least squares (PLS) models. The informative regions can easily be found by moving window partial least squares regression (MWPLSR) method. PLS calibration models using the regions obtained by SCMWPLS were developed for HSA, gamma-globulin, and glucose. These models showed good prediction with the smallest root mean square error of predictions (RMSEP), the relatively small number of PLS factors, and the highest correlation coefficients among the results achieved by using whole region and MWPLSR methods. The RMSEP values of HSA, gamma-globulin, and glucose yielded by SCMWPLS were 0.0303, 0.0327, and 0.0195 g/dl, respectively. These results prove that SCMWPLS can be successfully applied to determine simultaneously the concentrations of HSA, gamma-globulin, and glucose in complicated biological fluids such as CS IIB solutions by using NIR spectroscopy. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 26 条
[1]   Comparison of different variable selection methods conducted on NIR transmission measurements on intact tablets [J].
Abrahamsson, C ;
Johansson, J ;
Sparén, A ;
Lindgren, F .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 69 (1-2) :3-12
[2]  
[Anonymous], 1990, NEAR INFRARED TECHNO
[3]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[4]   MULTIVARIATE CALIBRATION FOR PROTEIN, CHOLESTEROL AND TRIGLYCERIDES IN HUMAN PLASMA USING SHORT-WAVE NEAR-INFRARED SPECTROMETRY [J].
BITTNER, A ;
MARBACH, R ;
HEISE, HM .
JOURNAL OF MOLECULAR STRUCTURE, 1995, 349 :341-344
[5]  
Domjan G., 1995, J NEAR INFRARED SPEC, V2, P67
[6]   Spectral regions selection to improve prediction ability of PLS models by changeable size moving window partial least squares and searching combination moving window partial least squares [J].
Du, YP ;
Liang, YZ ;
Jiang, JH ;
Berry, RJ ;
Ozaki, Y .
ANALYTICA CHIMICA ACTA, 2004, 501 (02) :183-191
[7]   REAGENTLESS NEAR-INFRARED DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING MULTIVARIATE CALIBRATION [J].
HAALAND, DM ;
ROBINSON, MR ;
KOEPP, GW ;
THOMAS, EV ;
EATON, RP .
APPLIED SPECTROSCOPY, 1992, 46 (10) :1575-1578
[8]   NEAR-INFRARED SPECTROSCOPIC DETERMINATION OF SERUM TOTAL PROTEINS, ALBUMIN, GLOBULINS, AND UREA [J].
HALL, JW ;
POLLARD, A .
CLINICAL BIOCHEMISTRY, 1993, 26 (06) :483-490
[9]  
HALL JW, 1992, CLIN CHEM, V38, P1623
[10]   Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy [J].
Hazen, KH ;
Arnold, MA ;
Small, GW .
ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) :255-267