Combined production of electricity, heat and cooling power in trigeneration represents a key option for the development of high-efficiency and cost-effective integrated energy systems. The complexity of the possible plant schemes calls for the adoption of general models handling multiple interconnected components and energy flows of various typologies. This paper presents a comprehensive input-output matrix approach aimed at modelling small-scale trigeneration equipment taking into account the interactions among plant components and external energy networks. Starting from the definitions of specific efficiency matrices for each plant component and from a matrix representation of the relevant interconnections, an overall efficiency matrix representing the whole plant is constructed. This construction is carried out by means of an original procedure, suitable for automatic and symbolic implementation, which, exploiting graph theory concepts, explores the tree formed by the backward paths from outputs to inputs. The proposed formulation maintains the separation among the individual energy vectors, each of which can be associated to its time-dependent price, providing the basic framework for formulating optimization problems concerning management of trigeneration systems within an energy market context. A numerical example referred to the optimal operation of a composite scheme with absorption and electric chillers is illustrated and discussed. The results obtained show the modelling effectiveness of the proposed matrix formulation. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:261 / 273
页数:13
相关论文
共 52 条
  • [1] Analysis of energy pricing in urban energy service systems considering a multiobjective problem of environmental and economic impact
    Aki, H
    Oyama, T
    Tsuji, K
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (04) : 1275 - 1282
  • [2] *AM SOC HEAT REFR, 2000, ASHRAE SYST EQU HDB
  • [3] A mixed integer programming model for optimal design of trigeneration in a hospital complex
    Arcuri, P.
    Florio, G.
    Fragiacomo, P.
    [J]. ENERGY, 2007, 32 (08) : 1430 - 1447
  • [4] Trigeneration in the food industry
    Bassols, J
    Kuckelkorn, B
    Langreck, J
    Schneider, R
    Veelken, H
    [J]. APPLIED THERMAL ENGINEERING, 2002, 22 (06) : 595 - 602
  • [5] BAUMERT LD, 1965, J ASSOC COMPUT MACH, V12, P516
  • [6] Multi-criteria optimization of a district cogeneration plant integrating a solid oxide fuel cell-gas turbine combined cycle, heat pumps and chillers
    Burer, M
    Tanaka, K
    Favrat, D
    Yamada, K
    [J]. ENERGY, 2003, 28 (06) : 497 - 518
  • [7] CALI M, 2004, EXERGY ENERGY SYSTEM
  • [8] Energy saving in airports by trigeneration. Part I: Assessing economic and technical potential
    Cardona, E
    Piacentino, A
    Cardona, F
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1427 - 1436
  • [9] Energy saving in airports by trigeneration. Part II: Short and long term planning for the Malpensa 2000 CHCP plant
    Cardona, E
    Sannino, P
    Piacentino, A
    Cardona, F
    [J]. APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1437 - 1447
  • [10] Cogeneration: a regulatory framework toward growth
    Cardona, E
    Piacentino, A
    [J]. ENERGY POLICY, 2005, 33 (16) : 2100 - 2111