Applications of Calixarenes as Potential Ionophores for Electrochemical Sensors

被引:22
作者
El Nashar, Rasha M. [2 ]
Wagdy, Hebat Allah A. [2 ]
Aboul-Enein, Hassan Y. [1 ]
机构
[1] Natl Res Ctr, Pharmaceut & Med Chem Dept, Cairo 12311, Egypt
[2] German Univ Cairo, Fac Pharm & Biotechnol, Dept Pharmaceut Chem, New Cairo, Egypt
关键词
Supramolecular ionophores; Calixarene; Electrochemical sensors; Alkali metals; Lanthanides; Potentiometry; Voltammetry; ION-SELECTIVE ELECTRODES; POLYMERIC MEMBRANE ELECTRODES; CHEMICALLY-MODIFIED ELECTRODE; GLASSY-CARBON ELECTRODE; POTENTIOMETRIC SENSOR; STRIPPING VOLTAMMETRY; TRACE DETERMINATION; NEUTRAL CARRIER; PASTE ELECTRODE; DERIVATIVES;
D O I
10.2174/157341109788680273
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Supramolecular ionophores have in the few past years gained increasing interest in the field of analytical chemistry because of their large varieties and applications in chemical sensors. Calixarenes are considered an important class of supramolecular compounds used in construction of many electrochemical sensors in the past years. This review discusses the main applications of calixarenes in the assay of pharmaceutical, biological and inorganic compounds using electrochemical sensors from 2001 up-to-date.
引用
收藏
页码:249 / 270
页数:22
相关论文
共 104 条
[1]   Novel plastic chromium (III)-ion selective electrodes based on different ionophoric species and plasticizing solvent mediators [J].
Akl, MA ;
Ghoneim, AK ;
Abd El-Aziz, MH .
ELECTROANALYSIS, 2006, 18 (03) :299-306
[2]   X-RAY CRYSTAL AND MOLECULAR-STRUCTURE OF THE PARA-TERT-BUTYLPHENOL-FORMALDEHYDE CYCLIC OCTAMER CYCLO(OCTA[(5-TERT-BUTYL-2-ACETOXY-1,3-PHENYLENE)METHYLENE]) [J].
ANDREETTI, GD ;
UNGARO, R ;
POCHINI, A .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1981, (11) :533-534
[3]   Cesium-selective poly(vinylchloride) membrane electrode based on a new calix[4]arene derivative in the 1,3-alternate conformation [J].
Arvand-Barmchi, M ;
Mousavi, MF ;
Zanjanchi, MA ;
Taghvaei, S .
ANALYTICAL LETTERS, 2002, 35 (05) :767-783
[4]  
Asfari Z., 2002, CALIXARENES 2001
[5]   A chloride selective sensor based on a calix[4]arene possessing a urea moiety [J].
Babu, J. Nagendra ;
Bhalla, Vandana ;
Kumar, Manoj ;
Mahajan, R. K. ;
Puri, Rajiv Kumar .
TETRAHEDRON LETTERS, 2008, 49 (17) :2772-2775
[6]  
BAHAMEL K, 2005, MICROCHIM ACTA, V149, P145
[7]  
Bazylak G, 2004, COMB CHEM HIGH T SCR, V7, P345
[8]   Potentiometric detection of exogenic beta-adrenergic substances in liquid chromatography [J].
Bazylak, G ;
Nagels, LJ .
JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) :85-96
[9]  
Bazylak Grzegorz, 2003, Farmaco (Lausanne), V58, P591, DOI 10.1016/S0014-827X(03)00096-X
[10]  
BEN AM, 2006, THIN SOLID FILMS, V495, P368