Preserved Diagnostic Performance of Dual-Source CT Coronary Angiography with Reduced Radiation Exposure and Cancer Risk

被引:39
作者
Weustink, Annick C. [1 ,2 ]
Mollet, Nico R. [1 ,2 ]
Neefjes, Lisan A. [1 ,2 ]
van Straten, Marcel [1 ]
Neoh, Eurick [1 ,2 ]
Kyrzopoulos, Stamatis [1 ,2 ]
Meijboom, Bob Willem [1 ,2 ]
van Mieghem, Carlos [1 ,2 ]
Cademartiri, Filippo [1 ]
de Feyter, Pim J. [1 ,2 ]
Krestin, Gabriel P. [1 ]
机构
[1] Erasmus MC, Dept Radiol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
关键词
SOURCE COMPUTED-TOMOGRAPHY; IMAGE QUALITY; SHOOT MODE; ACCURACY; INTERMEDIATE;
D O I
10.1148/radiol.2521082023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effects of standard and optimal electrocardiographic (ECG) pulsing on diagnostic performance, radiation dose, and cancer risk in symptomatic patients in a "real-world" clinical setting. Materials and Methods: The institutional review board approved the study, and all patients gave informed consent. Dual-source computed tomographic (CT) coronary angiography was performed in 436 symptomatic patients (301 men, 135 women; mean age, 61.6 years +/- 10.6 [ standard deviation]; age range, 23-89 years) referred for conventional coronary angiography. Standard and optimal ECG pulsing was performed in 327 and 109 patients, respectively. The diagnostic performance of dual-source CT coronary angiography for detection of significant stenosis (>= 50 luminal diameter reduction), with quantitative coronary angiography as the reference standard, was reported as sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios. The mean effective radiation dose, additional fatal cancer risk, and age- and sex-specific cancer risks related to one CT coronary angiographic examination were determined from data averaged over the study population. Results: Mean effective doses with standard and optimal ECG pulsing were 14.2 mSv +/- 3.2 and 10.7 mSv +/- 3.6, respectively. Optimal ECG pulsing resulted in a 43% overall reduction in mean effective radiation dose and cancer risk compared with a nonpulsing protocol (18.8 mSv +/- 3.5) and a 25% overall reduction in mean effective dose compared with the standard pulsing protocol. At patient-by-patient analysis, CT coronary angiography with standard ECG pulsing yielded sensitivity, specificity, and positive and negative predictive values of 100% (95% confidence interval [CI]: 99%, 100%), 85% ( 95% CI: 81%, 88%), 94% ( 95% CI: 91%, 96%), and 99% (95% CI: 98%, 100%), respectively, for detection of significant stenosis. Optimal ECG pulsing yielded similar results: Sensitivity, specificity, and positive and negative predictive values were 100% ( 95% CI: 100%, 100%), 88% ( 95% CI: 82%, 94%), 97% ( 95% CI: 93%, 100%), and 100%, respectively. Conclusion: Compared with a nonpulsing protocol, optimal ECG pulsing resulted in significant (P < .001) reductions in patient radiation dose and cancer risk (up to 55% reduction in patients with high heart rates) while preserving the diagnostic performance of dual-source CT coronary angiography. (C) RSNA, 2009
引用
收藏
页码:53 / 60
页数:8
相关论文
共 30 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]  
Austen W G, 1975, Circulation, V51, P5
[3]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
CLINICAL CHEMISTRY, 2003, 49 (01) :1-6
[4]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[5]   Abdominal CT and the Euratom Directive [J].
Dixon, AK ;
Goldstone, KE .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1567-1570
[6]  
Efron B., 1993, INTRO BOOTSTRAP, DOI 10.1007/978-1-4899-4541-9
[7]   Radiation dose to patients from cardiac diagnostic imaging [J].
Einstein, Andrew J. ;
Moser, Kevin W. ;
Thompson, Randall C. ;
Cerqueira, Manuel D. ;
Henzlova, Milena J. .
CIRCULATION, 2007, 116 (11) :1290-1305
[8]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323
[9]  
*EUR COMM, 2000, REF GUID IM
[10]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810