Comparative study of different tendon grasping techniques for arthroscopic repair of the rotator cuff

被引:33
作者
Baleani, Massimiliano
Ohman, Caroline
Guandalini, Luciano
Rotini, Roberto
Glavaresi, Gianluca
Traina, Francesco
Viceconti, Marco
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Medica, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Sez B Chirurg Ortoped Traumatol, I-40136 Bologna, Italy
[3] Ist Ortoped Rizzoli, Serv Chirurg Sperimentale, I-40136 Bologna, Italy
[4] Ist Ortoped Rizzoli, Div Chirurg Ortoped Traumatol 1, I-40136 Bologna, Italy
关键词
rotator cuff; repair technique; biomechanics; experimental testing; tensile strength;
D O I
10.1016/j.clinbiomech.2006.04.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. One cause of early failure of rotator cuff repairs is the pull out of the suture through the tendon. The aims of this study were to investigate the initial strength and failure mode of different tendon grasping techniques and to evaluate an alternative stitch proposed for arthroscopic repair of rotator cuff tendons. Methods. Four different stitches were investigated: simple stitch, Mattress, modified Mason-Allen and simple stitch closed over a horizontal loop. The last stitch was proposed as an alternative to the modified Mason-Allen stitch since the former is simpler to sew arthroscopically than the latter. The experimental procedure was designed to assess the mechanical behaviour of the stitches. Tests were performed using sheep infraspinatus tendons. Two different non-absorbable sutures were used. Each specimen was preloaded with about 30 N and then loaded to failure. Results. No significant difference was found in compliance among the four investigated stitches. Conversely, the tensile strength of the simple stitch and Mattress was lower than the tensile strength of the other two stitches, while no significant difference was observed between the modified Mason-Allen and the simple stitch closed over a horizontal loop. The maximum grasping power of these two 'reinforced' stitches was achieved only with the high-strength suture. Interpretation. The simple stitch closed over a horizontal loop seems to be an attractive alternative to the modified Mason-Allen for arthroscopic repair of the rotator cuff and it seems recommendable instead of simple or Mattress stitches. The use of a high-strength suture would increase the tensile strength of the grasping in the case of good quality tendon tissue. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:799 / 803
页数:5
相关论文
共 29 条
  • [1] Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques
    Baleani, M
    Schrader, S
    Veronesi, CA
    Rotini, R
    Giardino, R
    Toni, A
    [J]. CLINICAL BIOMECHANICS, 2003, 18 (08) : 721 - 729
  • [2] Cyclic loading of rotator cuff repairs: An in vitro biomechanical comparison of bioabsorbable tacks with transosseous sutures
    Bicknell, RT
    Harwood, C
    Ferreira, L
    King, GJW
    Johnson, JA
    Faber, K
    Drosdowech, D
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (07) : 875 - 880
  • [3] Open versus arthroscopic rotator cuff repair: A comparative view of 96 cases
    Buess, E
    Steuber, KU
    Waibl, B
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (05) : 597 - 604
  • [4] Bungaro P, 2005, Chir Organi Mov, V90, P113
  • [5] Cyclic loading of transosseous rotator cuff repairs: Tension overload as a possible cause of failure
    Burkhart, SS
    Johnson, TC
    Wirth, MA
    Athanasiou, KA
    [J]. ARTHROSCOPY, 1997, 13 (02): : 172 - 176
  • [6] Loop security as a determinant of tissue fixation security
    Burkhart, SS
    Wirth, MA
    Simonick, M
    Salem, D
    Lanctot, D
    Athanasiou, K
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1998, 14 (07) : 773 - 776
  • [7] Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique - Margin convergence versus direct tendon-to-bone repair
    Burkhart, SS
    Danaceau, SM
    Pearce, CE
    [J]. ARTHROSCOPY, 2001, 17 (09): : 905 - 912
  • [8] Mode of failure for rotator cuff repair with suture anchors identified at revision surgery
    Cummins, CA
    Murrell, GAC
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (02) : 128 - 133
  • [9] Early effectiveness of arthroscopic repair for full-thickness tears of the rotator cuff - An outcome analysis
    Gartsman, GM
    Brinker, MR
    Khan, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (01) : 33 - 40
  • [10] Experimental rotator cuff repair - A preliminary study
    Gerber, C
    Schneeberger, AG
    Perren, SM
    Nyffeler, RW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09) : 1281 - 1290