Low voltage electrically stimulated lab-on-a-chip device followed by red-green-blue analysis: a simple and efficient design for complicated matrices

被引:32
作者
Seidi, Shahram [1 ]
Rezazadeh, Maryam [2 ]
Yamini, Yadollah [2 ]
Zamani, Niki [3 ]
Esmaili, Sara [3 ]
机构
[1] KN Toosi Univ Technol, Fac Chem, Dept Analyt Chem, Tehran, Iran
[2] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[3] Natl Org Dev Except Talents, Farzanegan Educ Ctr 1, Tehran, Iran
关键词
LIQUID-LIQUID MICROEXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; ELECTRO MEMBRANE EXTRACTION; SOLID-PHASE MICROEXTRACTION; ELECTROMEMBRANE EXTRACTION; WATER SAMPLES; QUANTITATIVE-DETERMINATION; PULSED ELECTROMEMBRANE; MASS-SPECTROMETRY; BASIC DRUGS;
D O I
10.1039/c4an01124d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, a simple and portable analysis device was designed for the first time for the determination of lead ions as the model analyte. The basis of the lead analysis is its extraction and pre-concentration in an acceptor droplet via the application of an electrical field. The acceptor droplet is a KI solution and therefore, the formation of a yellow precipitation of PbI2 was a sign of the presence of lead ion in the solution. Following this, digital picture of the final acceptor droplet was analyzed by investigating its Red-Green-Blue (RGB) components. The results show that the RGB intensities of the acceptor phase are proportionate to the lead concentration in the sample solution. Also, a 9.0 V battery was used to apply the electrical field, and other effective parameters, such as the type of organic liquid membrane, pH of the sample solution, and the extraction time, were considered to obtain the optimal conditions. The model analyte was determined by extracting it from a 100 mu L sample solution across a thin layer of 1-octanol, immobilized in the pores of a polypropylene membrane sheet, and into the acceptor droplet via applying a 9.0 V electrical potential for 20 min. The device is capable of determining lead ions down to 20.0 ng mL(-1), with admissible repeatability and reproducibility (the intra- and inter-assay precision ranged between 3.8-7.0% and 9.8-11.9%, respectively). Also, we calculated error% for the model analyte in the range of -8.5 to +4.5, which suggests that the chip offers acceptable accuracy for the analysis of lead ions. The linearity was studied in the range of 50.0-1500 ng mL(-1), with a correlation coefficient of 0.9994. Finally, the designed device was used for the analysis of lead in real samples.
引用
收藏
页码:5531 / 5537
页数:7
相关论文
共 46 条
  • [1] AL-Othman Z. A., 2009, CHROMATOGRAPHIA, V69, pS13
  • [2] NANO CAPILLARY ELECTROPHORESIS IN MICROCHIPS: A NEED OF THE PRESENT CENTURY
    Al-Othman, Zeid A.
    Ali, Imran
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (14) : 1295 - 1325
  • [3] Ali I., 2014, CURR CHROMATOGR, V1, P81
  • [4] Ali I., 2009, NANOCHROMATOGRAPHY C
  • [5] Role of Nano Liquid Chromatography in Pharmaceutical Analyses
    Ali, Imran
    Aboul-Enein, Hassan Y.
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2009, 5 (04) : 367 - 380
  • [6] Ligandless temperature-controlled ionic liquid-phase microextraction of lead(II) ion prior to its determination by FAAS
    Alothman, Zeid A.
    Yilmaz, Erkan
    Habila, Mohamed
    Shabaka, Azza
    Soylak, Mustafa
    [J]. MICROCHIMICA ACTA, 2013, 180 (7-8) : 669 - 674
  • [7] Comparison of dry, wet and microwave digestion methods for the multi element determination in some dried fruit samples by ICP-OES
    Altundag, Huseyin
    Tuzen, Mustafa
    [J]. FOOD AND CHEMICAL TOXICOLOGY, 2011, 49 (11) : 2800 - 2807
  • [8] Aydinalp C, 2004, POL J ENVIRON STUD, V13, P233
  • [9] Electrokinetic migration of acidic drugs across a supported liquid membrane
    Balchen, Marte
    Gjelstad, Astrid
    Rasmussen, Knut Einar
    Pedersen-Bjergaard, Stig
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) : 220 - 225
  • [10] Simultaneous extraction of acidic and basic drugs at neutral sample pH: A novel electro-mediated microextraction approach
    Basheer, Chanbasha
    Lee, Jingyi
    Pedersen-Bjergaard, Stig
    Rasmussen, Knut Einar
    Lee, Hian Kee
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (43) : 6661 - 6667