摘要
Whole body imaging with radioiodine can detect functioning metastases, which can often be effectively treated with appropriate amounts of radioiodine. Non-physiologic I-131 uptake detected on images is usually interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does not always imply thyroid cancer metastases and has been reported on many occasions, including various non-thyroidal neoplasms, and contamination by body secretions. In order to avoid unnecessary therapeutic interventions it is extremely important to properly distinguish false-positive sites of I-131 localization. Three patients with unusual radioiodine contamination patterns, either presented for the first time or rarely presented in the existing literature, were reported. Reported cases consist of contamination in hair (due to styling hair with sputum), contamination in neck (due to drooling during sleep) and, contaminated chewing gum. False positive contamination sources were clarified by careful examination of patients and further images when necessary.
引用
收藏
页码:271 / 274
页数:4
相关论文
共 31 条
[1]   THE RADIOACTIVE WIG IN I-131 WHOLE-BODY IMAGING [J].
ABDELDAYEM, HM ;
HALKER, K ;
ELSAYED, M .
CLINICAL NUCLEAR MEDICINE, 1984, 9 (08) :454-455
[2]  
ACHONG DM, 1991, J NUCL MED, V32, P2275
[3]   FALSE-POSITIVE I-131 UPTAKE AT A TRACHEOSTOMY SITE DISCERNMENT WITH TL-201 IMAGING [J].
AIN, KB ;
SHIH, WJ .
CLINICAL NUCLEAR MEDICINE, 1994, 19 (07) :619-621
[4]  
BAKHEET S, 1993, EUR J NUCL MED, V20, P415
[5]   FALSE-POSITIVE RADIOIODINE WHOLE-BODY SCAN IN THYROID-CANCER PATIENTS DUE TO UNRELATED PATHOLOGY [J].
BAKHEET, SM ;
HAMMAMI, MM .
CLINICAL NUCLEAR MEDICINE, 1994, 19 (04) :325-329
[6]   FALSE-POSITIVE I-131 BODY SCAN CAUSED BY A LARGE RENAL CYST [J].
BRACHMAN, MB ;
ROTHMAN, BJ ;
RAMANNA, L ;
TANASESCU, DE ;
ADELBERG, H ;
WAXMAN, AD .
CLINICAL NUCLEAR MEDICINE, 1988, 13 (06) :416-418
[7]   AXILLARY I-131 ACCUMULATION DUE TO PERSPIRATION [J].
CAMPONOVO, EJ ;
GOYER, PF ;
SILVERMAN, ED ;
KISTLER, AM ;
YUDT, WM .
CLINICAL NUCLEAR MEDICINE, 1989, 14 (10) :762-763
[8]   UPTAKE OF I-131 BY A MECKEL DIVERTICULUM MIMICKING METASTATIC THYROID-CANCER [J].
CAPLAN, RH ;
GUNDERSEN, GA ;
ABELLERA, RM ;
KISKEN, WA .
CLINICAL NUCLEAR MEDICINE, 1987, 12 (09) :760-762
[9]   AN UNUSUAL CASE OF A FALSE-POSITIVE I-131 WHOLE-BODY SCAN IN A PATIENT WITH PAPILLARY THYROID-CANCER [J].
CECCARELLI, C ;
PACINI, F ;
LIPPI, F ;
PINCHERA, A .
CLINICAL NUCLEAR MEDICINE, 1988, 13 (03) :192-193
[10]   False-positive I-131 whole-body scan in follicular thyroid carcinoma caused by frontal sinus mucocele [J].
Duque, JJ ;
Miguel, MB ;
Ruiz, E ;
Castillo, L ;
Claver, M ;
Rubio, MJ ;
Calvo, JI ;
Rodriguez, A ;
Zamora, B ;
Casado, C .
CLINICAL NUCLEAR MEDICINE, 2000, 25 (02) :137-138