A Comparison of the Isometric Midthigh Pull and Isometric Squat: Intraday Reliability, Usefulness, and the Magnitude of Difference Between Tests

被引:35
作者
Brady, Claire J. [1 ]
Harrison, Andrew J. [1 ,2 ]
Flanagan, Eamonn P. [3 ]
Haff, G. Gregory [4 ]
Comyns, Thomas M. [1 ,2 ]
机构
[1] Univ Limerick, Dept Phys Educ & Sport Sci, Limerick, Ireland
[2] Univ Limerick, Hlth Res Inst, Limerick, Ireland
[3] Sport Ireland Inst, Natl Sports Campus, Dublin, Ireland
[4] Edith Cowen Univ, Ctr Exercise & Sports Sci Res, Joondalup, WA, Australia
关键词
isometric strength; force-time curve; maximum strength; explosive strength; performance testing; TIME CURVE CHARACTERISTICS; FORCE DEVELOPMENT; STRENGTH; PERFORMANCE; POSITION;
D O I
10.1123/ijspp.2017-0480
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: To examine the reliability and usefulness of the isometric midthigh pull (IMTP) and isometric squat (ISqT) performed at the same knee and hip angles. The scores produced in each test were compared to determine the magnitude of differences between tests. Methods: Twenty-six male and female athletes (age, 23.6 [4.3] y; height, 1.75 [0.07] m; and body mass, 68.8 [9.7] kg) performed 2 maximal repetitions of the IMTP and ISqT following a specific warm-up. Results: Maximum force, absolute peak force (PF), relative PF, allometrically scaled PF, rate of force development (0-200 and 0-250 ms), and impulse (0-300 ms) were deemed reliable (intraclass correlation coefficient [ICC] >=.86 and coefficient of variation [CV] <= 9.4%) in the IMTP and ISqT based on predetermined criteria (ICC >=.8 and CV <= 10%). Impulse (0-200 and 0-250 ms) was reliable in the ISqT (ICC >=.92 and CV <= 9.9%). Participants produced significantly (P < .05) greater PF and impulse (0-300 ms) during the ISqT compared with the IMTP. When split by sex, female participants produced significantly greater PF (P = .042) during the ISqT, with no significant differences among male participants (P = .245). Both tests are capable of detecting changes in performance in maximum force and absolute PF. Conclusions: Both tests are reliable for non-time-dependent maximal strength measures when measured at the same knee and hip angles. The ISqT may be preferred when coaches want to test an athlete's true maximum lower-limb strength, especially female athletes.
引用
收藏
页码:844 / 852
页数:9
相关论文
共 31 条
[11]  
Garhammer J., 1993, J STRENGTH COND RES, V7, P76, DOI DOI 10.1519/00124278-199305000-00002
[12]   A COMPARISON OF METHODS FOR DETERMINING THE RATE OF FORCE DEVELOPMENT DURING ISOMETRIC MIDTHIGH CLEAN PULLS [J].
Haff, G. Gregory ;
Ruben, Ryan P. ;
Lider, Joshua ;
Twine, Corey ;
Cormie, Prue .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (02) :386-395
[13]  
Haff GG, 2005, J STRENGTH COND RES, V19, P741
[14]  
Haff GG, 1997, J STRENGTH COND RES, V11, P269
[15]   The Effects of Attentional Focusing Instructions on Force Production During the Isometric Midthigh Pull [J].
Halperin, Israel ;
Williams, Kym J. ;
Martin, David T. ;
Chapman, Dale W. .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (04) :919-923
[16]   Understanding Position Transducer Technology for Strength and Conditioning Practitioners [J].
Harris, Nigel K. ;
Cronin, John ;
Taylor, Kristie-Lee ;
Boris, Jidovtseff ;
Sheppard, Jeremy .
STRENGTH AND CONDITIONING JOURNAL, 2010, 32 (04) :66-79
[17]  
HOLM S, 1979, SCAND J STAT, V6, P65
[18]  
Hopkins W.G., 2004, SPORTSCIENCE, V8, P1, DOI DOI 10.1097/00005768-199804000-00026
[19]  
Hopkins W.G., 2015, Sportsci, V19, P26
[20]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15