A Fault Location Method Using Direct Convolution: Electromagnetic Time Reversal or Not Reversal

被引:6
作者
Wang, Guanbo [1 ]
Zhuang, Chijie [1 ,2 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Int Joint Lab Low Carbon Clean Energy Innovat, Beijing 100084, Peoples R China
关键词
Fault location; Transient analysis; Electromagnetics; Convolution; Circuit faults; Lightning; Transmission line measurements; Direct convolution; electromagnetic time reversal (EMTR); fault location;
D O I
10.1109/TEMC.2022.3168012
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electromagnetic time reversal (EMTR) is drawing increasing interest in short-circuit fault location. In this article, we investigate the classic EMTR fault location methods and find that it is not necessary to reverse the obtained signal in time which is a standard operation in these methods before injecting it into the network. The effectiveness of the EMTR fault location method results from the specific similarity of the transfer functions in the forward and reverse processes. Therefore, we can inject an arbitrary type and length of source in the reverse process to locate the fault. Based on this observation, we propose a new EMTR fault location method using direct convolution. This method is different from the traditional methods, and it only needs to precalculate the assumed fault transients for a given network, which can be stored in embedded hardware. The faults can be located efficiently via direct convolution of the signal collected from a fault and the prestored calculated transients, even using a fraction of the fault signal.
引用
收藏
页码:1112 / 1116
页数:5
相关论文
共 14 条
  • [1] An Effective EMTR-Based High-Impedance Fault Location Method for Transmission Lines
    An, Jianwei
    Zhuang, Chijie
    Rachidi, Farhad
    Zeng, Rong
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (01) : 268 - 276
  • [2] Bogert B.P., 1957, IRE T COMMUN SYST, V5, P2
  • [3] Li JP, 2017, 2017 IEEE 2ND INTERNATIONAL CONFERENCE ON OPTO-ELECTRONIC INFORMATION PROCESSING (ICOIP), P1, DOI 10.1109/OPTIP.2017.8030687
  • [4] A Correlation-Based Electromagnetic Time Reversal Technique to Locate Indoor Transient Radiation Sources
    Li, Qi
    Wang, Zhaoyang
    Xie, Yan-Zhao
    Rachidi, Farhad
    Rubinstein, Marcos
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (09) : 3945 - 3957
  • [5] Lugrin G, 2015, IEEE INT SYMP ELEC, P209, DOI 10.1109/ISEMC.2015.7256160
  • [6] Manesh HM, 2012, IEEE INT WORK SIGN P, P469, DOI 10.1109/SPAWC.2012.6292952
  • [7] Rachidi F, 2017, ELECTROMAGNETIC TIME REVERSAL: APPLICATION TO ELECTROMAGNETIC COMPATIBILITY AND POWER SYSTEMS, P1
  • [8] Assessment of the Influence of Losses on the Performance of the Electromagnetic Time Reversal Fault Location Method
    Razzaghi, Reza
    Lugrin, Gaspard
    Rachidi, Farhad
    Paolone, Mario
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (05) : 2303 - 2312
  • [9] An Efficient Method Based on the Electromagnetic Time Reversal to Locate Faults in Power Networks
    Razzaghi, Reza
    Lugrin, Gaspard
    Manesh, Hossein
    Romero, Carlos
    Paolone, Mario
    Rachidi, Farhad
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (03) : 1663 - 1673
  • [10] Distribution Line Fault Location With Unknown Fault Impedance Based on Electromagnetic Time Reversal
    Sun, Jian
    Yang, Qing
    Cui, Haonan
    Ran, Jiaquan
    Liu, Hongwen
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (06) : 1921 - 1929