Flexible Bioimpedance Sensor for Label-Free Detection of Cell Viability and Biomass

被引:19
作者
Fernandez, Renny Edwin [1 ]
Lebiga, Elise [1 ]
Koklu, Anil [1 ]
Sabuncu, Ahmet Can [1 ]
Beskok, Ali [1 ]
机构
[1] So Methodist Univ, Bobby B Lyle Sch Engn, Dept Mech Engn, Dallas, TX 75205 USA
关键词
Biomass; biosensing; impedance; label-free; microfluidics; FLOW CYTOMETER; DIELECTRIC-SPECTROSCOPY; BIOLOGICAL CELLS; IMPEDANCE; CULTURE;
D O I
10.1109/TNB.2015.2451594
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We introduce a flexible microfluidic bioimpedance sensor that is capable of detecting biomass and cell viability variations in a cell suspension. The sensor is developed on indium tin oxide (ITO) coated polyethylene terephthalate (PET) substrate and is devoid of gold, silicon, PDMS, or glass. In conjugation with a custom built PCB read-out module, the impedance characteristics of a cell suspension can be measured within one minute of sample introduction using liquid volumes less than 5 mu L. The portable sensor system occupies very little bench space and has the potential to be developed as a disposable electrical bioimpedance probe for rapid detection of dielectric variations in a biological suspension. The sensor is designed to generate a differential impedance spectra exclusive to a cell suspension with a dual-electrode-pair system. The potential of the sensor to discriminate between live and heat treated Saccharomyces cerevisiae is demonstrated in this study. The disposable sensor along with the distance variation technique is touted to be an inexpensive alternative to some of the existing online disposable biomass detection probes and electrochemical sensors.
引用
收藏
页码:700 / 706
页数:7
相关论文
共 48 条
[41]   Flow cytometer electronics [J].
Snow, C .
CYTOMETRY PART A, 2004, 57A (02) :63-69
[42]   Dielectric characterization of costal cartilage chondrocytes [J].
Stacey, Michael W. ;
Sabuncu, Ahmet C. ;
Beskok, Ali .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2014, 1840 (01) :146-152
[43]   Toxicity of Gold Nanoparticles on Somatic and Reproductive Cells [J].
Taylor, U. ;
Barchanski, A. ;
Garrels, W. ;
Klein, S. ;
Kues, W. ;
Barcikowski, S. ;
Rath, D. .
NANO-BIOTECHNOLOGY FOR BIOMEDICAL AND DIAGNOSTIC RESEARCH, 2012, 733 :125-133
[44]   Disposable electrochemical sensors: A mini review [J].
Thiyagarajan, Natarajan ;
Chang, Jen-Lin ;
Senthilkumar, Krishnan ;
Zen, Jyh-Myng .
ELECTROCHEMISTRY COMMUNICATIONS, 2014, 38 :86-90
[45]   A unified approach to dielectric single cell analysis: Impedance and dielectrophoretic force spectroscopy [J].
Valero, Ana ;
Braschler, Thomas ;
Renaud, Philippe .
LAB ON A CHIP, 2010, 10 (17) :2216-2225
[46]   Cell Stiffness Is a Biomarker of the Metastatic Potential of Ovarian Cancer Cells [J].
Xu, Wenwei ;
Mezencev, Roman ;
Kim, Byungkyu ;
Wang, Lijuan ;
McDonald, John ;
Sulchek, Todd .
PLOS ONE, 2012, 7 (10)
[47]   On-line, real-time measurements of cellular biomass using dielectric spectroscopy [J].
Yardley, YE ;
Kell, DB ;
Barrett, J ;
Davey, CL .
BIOTECHNOLOGY & GENETIC ENGINEERING REVIEWS, VOL 17, 2000, 17 :3-35
[48]   Low-cost rapid prototyping of flexible microfluidic devices using a desktop digital craft cutter [J].
Yuen, Po Ki ;
Goral, Vasiliy N. .
LAB ON A CHIP, 2010, 10 (03) :384-387