Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures

被引:37
作者
Chiang, PP
Roach, S
Baratz, ME
机构
[1] Allegheny Gen Hosp, Div Upper Extrem Surg, Dept Orthopaed Surg, Pittsburgh, PA 15212 USA
[2] Ithaca Orthopaed Grp, PC, Ithaca, NY USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2002年 / 27A卷 / 04期
关键词
distal radius fracture; Pi plate; retinacular flap; dorsal plating;
D O I
10.1053/jhsu.2002.33703
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patients with distal radius fractures that had been treated with a dorsal Pi plate and retinacular flap covering the transverse limb of the Pi plate were evaluated clinically and radiographically. Nine of 20 patients (45%) required plate removal for dorsal wrist pain. Three of the remaining 11 who retained the plate had dorsal tenderness over the wrist extensors. There were no differences evident between the 2 groups in plate size, position, or number of screws used. in addition there were no significant differences between the groups in either radial height or inclination. The palmar tilt did show a trend toward statistical significance: those patients who required plate removal had an average of 4.1degrees of dorsal tilt, patients whose plate was not removed averaged 2.8degrees of palmar tilt. Our results show that the retinacular flap covering the distal transverse limb of the Pi plate did not prevent the occurrence of dorsal wrist pain. Dorsal wrist pain remained a problem with dorsal plating of distal radius fractures. Copyright (C) 2002 by the American Society for Surgery of the Hand.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 19 条
  • [1] OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS
    AXELROD, TS
    MCMURTRY, RY
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01): : 1 - 11
  • [2] Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures
    Carter, PR
    Frederick, HA
    Laseter, GF
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02): : 300 - 307
  • [4] Treatment of displaced intra-articular fractures of the distal end of the radius with plates
    Fitoussi, F
    Ip, WY
    Chow, SP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) : 1303 - 1312
  • [5] HASTINGS H, 1993, ORTHOP CLIN N AM, V24, P309
  • [6] THE DIFFERENCES IN TOXICITY AND RELEASE OF BONE-RESORBING MEDIATORS INDUCED BY TITANIUM AND COBALT-CHROMIUM-ALLOY WEAR PARTICLES
    HAYNES, DR
    ROGERS, SD
    HAY, S
    PEARCY, MJ
    HOWIE, DW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06) : 825 - 834
  • [7] Closed reduction and external fixation of unstable fractures of the distal radius
    Hove, LM
    Furnes, O
    Nilsen, PT
    Oulie, HE
    Solheim, E
    Molster, AO
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1997, 31 (02): : 159 - 164
  • [8] Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report
    Kambouroglou, GK
    Axelrod, TS
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04): : 737 - 741
  • [9] Kovacik MW, 2000, CLIN ORTHOP RELAT R, P186
  • [10] LEIBOVIC SJ, 1994, ORTHOP CLIN N AM, V25, P685