Twin fetuses: Intravascular microbubble US contrast agent administration - Early experience

被引:28
作者
Denbow, ML
Welsh, AW
Taylor, MJ
Blomley, MJK
Cosgrove, DO
Fisk, NM
机构
[1] Queen Charlottes & Chelsea Hosp, Imperial Coll, Sch Med, Dept Maternal & Fetal Med, London W6 0NX, England
[2] Queen Charlottes & Chelsea Hosp, Imperial Coll, Sch Med, Dept Imaging, London W6 0NX, England
[3] Hammersmith Hosp, Imperial Coll, Sch Med, Dept Imaging, London W6 0NX, England
[4] Queen Charlottes & Chelsea Hosp, Imperial Coll, Sch Med, Dept Maternal & Fetal Med, London W6 0NX, England
关键词
contrast media; experimental studies; fetus; blood supply; US; microbubbles; placenta; abnormalities; pregnancy; twins; ultrasound; (US); power Doppler studies;
D O I
10.1148/radiology.214.3.r00mr08724
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To explore the feasibility of administering SH U 508A by using a single-needle procedure at ultrasonography (US) in twin pregnancies to confirm interfetal transfusion in monochorionic twins and delineate placental angioarchitecture in pregnancies with twin-twin transfusion syndrome. MATERIALS AND METHODS: Fourteen twin pregnancies were studied over 12 months: seven with monochorionic twins, including six with twin-twin transfusion syndrome; two of unknown chorionicity; and five with known dichorionic twins discordant for fetal karyotype or anomaly and undergoing selective feticide in the third trimester. Bolus injection of 100 mu L/kg of estimated fetoplacental weight of 400 mg/mL of SH U 508A was performed in the intrahepatic vein of one twin, and evidence of interfetal transfusion was sought by means of digital analysis of power Doppler signals in the contralateral twin. RESULTS: Contralateral twin echo enhancement was seen in four of the nine ultimately histopathologically proved monochorionic twins. As expected, no evidence of echo enhancement in the contralateral twin was seen in any of the five dichorionic twin pregnancies. There was no evidence of fetal compromise associated with the procedure. CONCLUSION: These pilot results suggest that microbubbles can be used to demonstrate interfetal transfusion but not to delineate placental vascular anatomy.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 20 条
  • [1] SEGMENTATION AND ANALYSIS OF COLOR DOPPLER IMAGES OF TUMOR VASCULATURE
    BELL, DS
    BAMBER, JC
    ECKERSLEY, RJ
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (05) : 635 - 647
  • [2] Microbubble echo-enhancers: A new direction for ultrasound?
    Blomley, M
    Cosgrove, D
    [J]. LANCET, 1997, 349 (9069) : 1855 - 1856
  • [3] Can relative contrast agent concentration be measured in vivo with color Doppler US?
    Blomley, MJK
    Albrecht, T
    Cosgrove, DO
    Bamber, JC
    [J]. RADIOLOGY, 1997, 204 (01) : 279 - 280
  • [4] Denbow M, 1998, PRENATAL DIAG, V18, P941, DOI 10.1002/(SICI)1097-0223(199809)18:9<941::AID-PD427>3.0.CO
  • [5] 2-G
  • [6] DENBOW M, IN PRESS AM J OBSTET
  • [7] Neonatal cranial ultrasonographic findings in preterm twins complicated by severe fetofetal transfusion syndrome
    Denbow, ML
    Battin, MR
    Cowan, F
    Azzopardi, D
    Edwards, AD
    Fisk, NM
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1998, 178 (03) : 479 - 483
  • [8] Ultrasound microbubble contrast angiography in monochorionic twin fetuses
    Denbow, ML
    Blomley, MJK
    Cosgrove, DO
    Fisk, NM
    [J]. LANCET, 1997, 349 (9054) : 773 - 773
  • [9] Colour Doppler energy insonation of placental vasculature in monochorionic twins: absent arterio-arterial anastomoses in association with twin-to-twin transfusion syndrome
    Denbow, ML
    Cox, P
    Talbert, D
    Fisk, NM
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1998, 105 (07): : 760 - 765
  • [10] Duncan KR, 1997, PRENATAL DIAG, V17, P1227, DOI 10.1002/(SICI)1097-0223(199712)17:13<1227::AID-PD328>3.0.CO