Determination of copper in airborne particulate matter using slurry sampling and chemical vapor generation atomic absorption spectrometry

被引:11
作者
Silva, Laiana O. B. [1 ]
Leao, Danilo J. [2 ]
dos Santos, Debora C. [1 ]
Matos, Geraldo D. [2 ]
de Andrade, Jailson B. [1 ]
Ferreira, Sergio L. C. [2 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170270 Salvador, BA, Brazil
[2] Univ Fed Bahia, INCT, BR-40170290 Salvador, BA, Brazil
关键词
Copper; Airborne particulate matter; CVG QT-AAS; Slurry sampling; OPTIMIZATION; HYDRIDE; METALS; TRANSITION;
D O I
10.1016/j.talanta.2014.04.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes the development of a method for the determination of copper in airborne particulate matter using slurry sampling and chemical vapor generation atomic absorption spectrometry (CVG AAS). Chemometric tools were employed to characterize the influence of several factors on the generation of volatile copper species. First, a two-level full factorial design was performed that included the following chemical variables: hydrochloric acid concentration, tetrahydroborate concentration, sulfanilamide concentration and tetrahydroborate volume, using absorbance as the response. Under the established experimental conditions, the hydrochloric acid concentration had the greatest influence on the generation of volatile copper species. Subsequently, a Box-Behnken design was performed to determine the optimum conditions for these parameters. A second chemometric study employing a two-level full factorial design was performed to evaluate the following physical factors: tetrahydroborate flow rate, flame composition, alcohol volume and sample volume. The results of this study demonstrated that the tetrahydroborate flow rate was critical for the process. The chemometric experiments determined the following experimental conditions for the method: hydrochloric acid concentration, 0.208 M; tetrahydroborate concentration, 4.59%; sulfanilamide concentration, 0.79%; tetrahydroborate volume, 2.50 mL; tetrahydroborate flow rate, 6.50 mL min(-1); alcohol volume, 200 mu L; and sample volume, 7.0 mL. Thus, this method, using a slurry volume of 500 mu L and a final dilution of 7 mL, allowed for the determination of copper with limits of detection and quantification of 0.30 and 0.99 mu g L-1, respectively. Precisions, expressed as RSD%, of 4.6 and 2.8% were obtained using copper solutions at concentrations of 5.0 and 50.0 mu g L-1, respectively. The accuracy was evaluated by the analysis of a certified reference material of urban particulate matter. The copper concentration obtained was 570 +/- 63 mg kg(-1), and the certified value was 610 +/- 70 mg kg(-1). This method was applied for the determination of copper in airborne particulate matter samples collected in two Brazilian regions of Bahia State, Brazil. The copper contents found varied from 14.46 to 164.31 ng m(-3). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 145
页数:6
相关论文
共 26 条
[1]   Response surface methodology (RSM) as a tool for optimization in analytical chemistry [J].
Bezerra, Marcos Almeida ;
Santelli, Ricardo Erthal ;
Oliveira, Eliane Padua ;
Villar, Leonardo Silveira ;
Escaleira, Luciane Amlia .
TALANTA, 2008, 76 (05) :965-977
[2]  
Bruns R.E., 2006, Statistical Design-Chemometrics
[3]   Formation of secondary organic aerosols from isoprene and its gas-phase oxidation products through reaction with hydrogen peroxide [J].
Claeys, M ;
Wang, W ;
Ion, AC ;
Kourtchev, I ;
Gelencsér, A ;
Maenhaut, W .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (25) :4093-4098
[4]  
de Almeida TS, 2013, J BRAZIL CHEM SOC, V24, P700, DOI 10.5935/0103-5053.20130086
[5]   Determination of mercury in phosphate fertilizers by cold vapor atomic absorption spectrometry [J].
de Jesus, Robson M. ;
Silva, Laiana O. B. ;
Castro, Jacira T. ;
de Azevedo Neto, Andre D. ;
de Jesus, Raildo M. ;
Ferreira, Sergio L. C. .
TALANTA, 2013, 106 :293-297
[6]   Determination of vanadium in soils and sediments by the slurry sampling graphite furnace atomic absorption spectrometry using permanent modifiers [J].
Dobrowolski, Ryszard ;
Adamczyk, Agnieszka ;
Otto, Magdalena .
TALANTA, 2013, 113 :19-25
[7]   Determination of gold in geological materials by carbon slurry sampling graphite furnace atomic absorption spectrometry [J].
Dobrowolski, Ryszard ;
Kurylo, Michal ;
Otto, Magdalena ;
Mroz, Agnieszka .
TALANTA, 2012, 99 :750-757
[8]   On-line preconcentration of zinc on ethyl vinyl acetate prior to its determination by CVG-ICP-OES [J].
Escudero, L. A. ;
Cerutti, S. ;
Martinez, L. D. ;
Salonia, J. A. ;
Gasquez, J. A. .
MICROCHEMICAL JOURNAL, 2013, 106 :34-40
[9]   Box-Behnken design: An alternative for the optimization of analytical methods [J].
Ferreira, S. L. C. ;
Bruns, R. E. ;
Ferreira, H. S. ;
Matos, G. D. ;
David, J. M. ;
Brandao, G. C. ;
da Silva, E. G. P. ;
Portugal, L. A. ;
dos Reis, P. S. ;
Souza, A. S. ;
dos Santos, W. N. L. .
ANALYTICA CHIMICA ACTA, 2007, 597 (02) :179-186
[10]  
He L, 2008, ATOM SPECTROSC, V29, P93