Concrete Cover Separation in FRP-Plated RC Beams: Mitigation Using FRP U-Jackets

被引:62
作者
Fu, B. [1 ,2 ]
Teng, J. G. [3 ]
Chen, J. F. [1 ,4 ]
Chen, G. M. [1 ]
Guo, Y. C. [1 ]
机构
[1] Guangdong Univ Technol, Sch Civil & Transportat Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[3] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Struct Engn, Hong Kong, Hong Kong, Peoples R China
[4] Queens Univ Belfast, Sch Planning Architecture & Civil Engn, Belfast BT9 5AG, Antrim, North Ireland
关键词
Fiber-reinforced polymer (FRP); Flexural strengthening; RC beam; Concrete cover separation; Debonding; U-jacketing; STRENGTH; ANCHORAGE;
D O I
10.1061/(ASCE)CC.1943-5614.0000721
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete cover separation is a common failure mode of RC beams strengthened with a fiber-reinforced polymer (FRP) plate externally bonded to the tension face (FRP-plated RC beams). This failure mode initiates at the critical plate end and then propagates at the level of steel tension reinforcement in the direction of increasing moment. Plate-end anchorage by FRP U-jackets has been specified in some design guidelines as a mitigation measure to delay or suppress concrete cover separation, although its effectiveness is far from clear. This mitigation method is more attractive than other options because the same strengthening material is used and the installation procedure is simple. This paper presents the first systematic experimental study on the use of FRP U-jackets for mitigating plate-end concrete cover separation failure, with particular attention to the effect of inclination angle between the U-jacket and the beam axis. A total of 10 full-scale FRP-plated RC beams were tested. The test results show that both the load-carrying capacity and the ductility of an FRP-plated RC beam can be significantly enhanced by FRP U-jacketing at the critical plate end. Inclined U-jacketing at 45 degrees to the beam axis was found to be much more effective than vertical U-jacketing (i.e.,at 90 degrees to the beam axis) in mitigating plate-end cover separation failure.
引用
收藏
页数:13
相关论文
共 37 条
[1]  
[Anonymous], 2008, 4402R ACI
[2]  
ASTM, 2010, ASTM D7565/D7565M-10
[3]  
ASTM International, 2008, D3039 ASTM
[4]  
Breña SF, 2003, ACI STRUCT J, V100, P36
[5]  
BSI (British Standards Institution), 2009, Metallic materials-Tensile testing-Part 1: Method of test at ambient temperature
[6]  
Buyle-Bodin F, 2016, J. Ind. Text, V33, P145, DOI DOI 10.1177/1528083704039251
[8]   Evaluation of Bond Strength in Concrete Elements Externally Reinforced with CFRP Sheets and Anchoring Devices [J].
Ceroni, Francesca ;
Pecce, Marisa .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) :521-530
[9]   Anchorage strength models for FRP and steel plates bonded to concrete [J].
Chen, JF ;
Teng, JG .
JOURNAL OF STRUCTURAL ENGINEERING, 2001, 127 (07) :784-791
[10]  
China Planning Press, 2010, GB50608