Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction

被引:14
|
作者
Jia, Qianjun [1 ,2 ,3 ]
Zhuang, Jian [4 ]
Jiang, Jun [5 ]
Li, Jiahua [3 ]
Huang, Meiping [1 ,3 ]
Liang, Changhong [1 ,2 ,3 ]
机构
[1] Southern Med Univ, Guangzhou, Guangdong, Peoples R China
[2] Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Radiol, Guangzhou, Peoples R China
[3] Guangdong Gen Hosp, Guangdong Acad Med Sci, Guangdong Cardiovasc Inst,Dept Catheterizat L, Guangdong Prov Key Lab South China Struct Heart, Guangzhou, Guangdong, Peoples R China
[4] Guangdong Gen Hosp, Guangdong Acad Med Sci, Guangdong Cardiovasc Inst,Dept Card Surg, Guangdong Prov Key Lab South China Struct Heart, Guangzhou, Guangdong, Peoples R China
[5] Shenzhen Second Peoples Hosp, Dept Radiol, Shenzhen, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Congenital heart disease; Multidetector CT; Hybrid iterative reconstruction; Iterative model reconstruction; RADIATION-DOSE REDUCTION; LOW TUBE VOLTAGE; COMPUTED-TOMOGRAPHY; CARDIAC-CT; CORONARY-ANGIOGRAPHY; YOUNG-CHILDREN; FEASIBILITY; ALGORITHMS; ACCURACY; EXPOSURE;
D O I
10.1016/j.ejrad.2016.10.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the image quality, rate of coronary artery visualization and diagnostic accuracy of 256-slice multi-detector computed tomography angiography (CTA) with prospective electrocardiographic (ECG) triggering at a tube voltage of 80 kVp between 3 reconstruction algorithms (filtered back projection (FBP), hybrid iterative reconstruction (iDose(4)) and iterative model reconstruction (IMR)) in infants with congenital heart disease (CHD). Methods: Fifty-one infants with CHD who underwent cardiac CTA in our institution between December 2014 and March 2015 were included. The effective radiation doses were calculated. Imaging data were reconstructed using the FBP, iDose4 and IMR algorithms. Parameters of objective image quality (noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)); subjective image quality (overall image quality, image noise and margin sharpness); coronary artery visibility; and diagnostic accuracy for the three algorithms were measured and compared. Results: The mean effective radiation dose was 0.61 +/- 0.32 mSv. Compared to FBP and iDose4, IMR yielded significantly lower noise (P < 0.01), higher SNR and CNR values (P < 0.01), and a greater subjective image quality score (P < 0.01). The total number of coronary segments visualized was significantly higher for both iDose4 and IMR than for FBP (P = 0.002 and P=0.025, respectively), but there was no significant difference in this parameter between iDose4 and IMR (P = 0.397). There was no significant difference in the diagnostic accuracy between the FBP, iDose4 and IMR algorithms (x(2) = 0.343, P = 0.842). Conclusions: For infants with CHD undergoing cardiac CTA, the IMR reconstruction algorithm provided significantly increased objective and subjective image quality compared with the FBP and iDose4 algorithms. However, IMR did not improve the diagnostic accuracy or coronary artery visualization compared with iDose4. (C) 2016 Published by Elsevier Ireland Ltd.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [41] Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: Image quality assessment in the cervicothoracic region
    Katsura, Masaki
    Sato, Jiro
    Akahane, Masaaki
    Matsuda, Izuru
    Ishida, Masanori
    Yasaka, Koichiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 356 - 360
  • [42] Image quality and radiation dose of CT venography with double dose reduction using model based iterative reconstruction: comparison with conventional CT venography using filtered back projection
    Jeong, Yeo-Jin
    Choo, Ki Seok
    Nam, Kyung Jin
    Lee, Ji Won
    Kim, Jin You
    Jung, Hyuk Jae
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2018, 59 (05) : 546 - 552
  • [43] Objective phantom-based and porcine model comparison of filtered back projection, adaptive statistical iterative reconstruction and model based iterative reconstruction algorithms
    Omotayo, Azeez
    Elbakri, Idris
    MEDICAL PHYSICS, 2014, 41 (08) : 7 - 7
  • [44] Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques in brain CT
    Ren, Qingguo
    Dewan, Sheilesh Kumar
    Li, Ming
    Li, Jianying
    Mao, Dingbiao
    Wang, Zhenglei
    Hua, Yanqing
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2597 - 2601
  • [45] Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction Techniques
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Hsieh, Jiang
    Licato, Paul E.
    Do, Synho
    Pien, Homer H.
    Blake, Michael A.
    RADIOLOGY, 2010, 257 (02) : 373 - 383
  • [46] Comparison of the Effect of Iterative Reconstruction versus Filtered Back Projection on Cardiac CT Postprocessing
    Spears, J. Reid
    Schoepf, U. Joseph
    Henzler, Thomas
    Joshi, Gayatri
    Moscariello, Antonio
    Vliegenthart, Rozemarijn
    Cho, Young Jun
    Apfaltrer, Paul
    Rowe, Garrett
    Weininger, Markus
    Ebersberger, Ullrich
    ACADEMIC RADIOLOGY, 2014, 21 (03) : 318 - 324
  • [47] Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial
    Montet, Xavier
    Hachulla, Anne-Lise
    Neroladaki, Angeliki
    Lador, Frederic
    Rochat, Thierry
    Botsikas, Diomidis
    Becker, Christoph D.
    EUROPEAN RADIOLOGY, 2015, 25 (06) : 1665 - 1671
  • [48] Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial
    Xavier Montet
    Anne-Lise Hachulla
    Angeliki Neroladaki
    Frederic Lador
    Thierry Rochat
    Diomidis Botsikas
    Christoph D. Becker
    European Radiology, 2015, 25 : 1665 - 1671
  • [49] Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT-Initial experience
    Takx, Richard A. P.
    Schoepf, U. Joseph
    Moscariello, Antonio
    Das, Marco
    Rowe, Garrett
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 275 - 280
  • [50] Model-based Iterative CT Image Reconstruction on GPUs
    Sabne, Amit
    Wang, Xiao
    Kisner, Sherman
    Bouman, Charles
    Raghunathan, Anand
    Midkiff, Samuel
    ACM SIGPLAN NOTICES, 2017, 52 (08) : 207 - 220