Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction

被引:14
|
作者
Jia, Qianjun [1 ,2 ,3 ]
Zhuang, Jian [4 ]
Jiang, Jun [5 ]
Li, Jiahua [3 ]
Huang, Meiping [1 ,3 ]
Liang, Changhong [1 ,2 ,3 ]
机构
[1] Southern Med Univ, Guangzhou, Guangdong, Peoples R China
[2] Guangdong Gen Hosp, Guangdong Acad Med Sci, Dept Radiol, Guangzhou, Peoples R China
[3] Guangdong Gen Hosp, Guangdong Acad Med Sci, Guangdong Cardiovasc Inst,Dept Catheterizat L, Guangdong Prov Key Lab South China Struct Heart, Guangzhou, Guangdong, Peoples R China
[4] Guangdong Gen Hosp, Guangdong Acad Med Sci, Guangdong Cardiovasc Inst,Dept Card Surg, Guangdong Prov Key Lab South China Struct Heart, Guangzhou, Guangdong, Peoples R China
[5] Shenzhen Second Peoples Hosp, Dept Radiol, Shenzhen, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Congenital heart disease; Multidetector CT; Hybrid iterative reconstruction; Iterative model reconstruction; RADIATION-DOSE REDUCTION; LOW TUBE VOLTAGE; COMPUTED-TOMOGRAPHY; CARDIAC-CT; CORONARY-ANGIOGRAPHY; YOUNG-CHILDREN; FEASIBILITY; ALGORITHMS; ACCURACY; EXPOSURE;
D O I
10.1016/j.ejrad.2016.10.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the image quality, rate of coronary artery visualization and diagnostic accuracy of 256-slice multi-detector computed tomography angiography (CTA) with prospective electrocardiographic (ECG) triggering at a tube voltage of 80 kVp between 3 reconstruction algorithms (filtered back projection (FBP), hybrid iterative reconstruction (iDose(4)) and iterative model reconstruction (IMR)) in infants with congenital heart disease (CHD). Methods: Fifty-one infants with CHD who underwent cardiac CTA in our institution between December 2014 and March 2015 were included. The effective radiation doses were calculated. Imaging data were reconstructed using the FBP, iDose4 and IMR algorithms. Parameters of objective image quality (noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)); subjective image quality (overall image quality, image noise and margin sharpness); coronary artery visibility; and diagnostic accuracy for the three algorithms were measured and compared. Results: The mean effective radiation dose was 0.61 +/- 0.32 mSv. Compared to FBP and iDose4, IMR yielded significantly lower noise (P < 0.01), higher SNR and CNR values (P < 0.01), and a greater subjective image quality score (P < 0.01). The total number of coronary segments visualized was significantly higher for both iDose4 and IMR than for FBP (P = 0.002 and P=0.025, respectively), but there was no significant difference in this parameter between iDose4 and IMR (P = 0.397). There was no significant difference in the diagnostic accuracy between the FBP, iDose4 and IMR algorithms (x(2) = 0.343, P = 0.842). Conclusions: For infants with CHD undergoing cardiac CTA, the IMR reconstruction algorithm provided significantly increased objective and subjective image quality compared with the FBP and iDose4 algorithms. However, IMR did not improve the diagnostic accuracy or coronary artery visualization compared with iDose4. (C) 2016 Published by Elsevier Ireland Ltd.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [31] Quantifying Differences in Image Quality Between Filtered Backprojection, An Adaptive Iterative Reconstruction Algorithm, and a Model-Based Iterative Reconstruction Algorithm for CT
    Whitson, H.
    Griglock, T.
    DeWeese, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3113 - 3113
  • [32] Diagnostic Accuracy of Coronary CT Angiography: Comparison of Filtered Back Projection and Iterative Reconstruction With Different Strengths
    Wang, Rui
    Schoepf, U. Joseph
    Wu, Runze
    Nance, John W., Jr.
    Lv, Biao
    Yang, Hua
    Li, Fang
    Lu, Dongxu
    Zhang, Zhaoqi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (02) : 179 - 184
  • [33] Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi
    Vardhanabhuti V.
    Ilyas S.
    Gutteridge C.
    Freeman S.J.
    Roobottom C.A.
    Insights into Imaging, 2013, 4 (5) : 661 - 669
  • [34] Comparison of Iterative Model Reconstruction versus Filtered Back-Projection in Pediatric Emergency Head CT: Dose, Image Quality, and Image-Reconstruction Times
    Southard, R. N.
    Bardo, D. M. E.
    Temkit, M. H.
    Thorkelson, M. A.
    Augustyn, R. A.
    Martinot, C. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : 866 - 871
  • [35] Comparison of Iterative Model-Based Reconstruction Versus Conventional Filtered Back Projection and Hybrid Iterative Reconstruction Techniques: Lesion Conspicuity and Influence of Body Size in Anthropomorphic Liver Phantoms
    Yoon, Jeong Hee
    Lee, Jeong Min
    Yu, Mi Hye
    Baek, Jee Hyun
    Jeon, Ju Hyun
    Hur, Bo Yun
    Dhanantwari, Amar
    Chung, Se Young
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 859 - 868
  • [36] Task-based characterization of a deep learning image reconstruction and comparison with filtered back-projection and a partial model-based iterative reconstruction in abdominal CT: A phantom study
    Racine, Damien
    Becce, Fabio
    Viry, Anais
    Monnin, Pascal
    Thomsen, Brian
    Verdun, Francis R.
    Rotzinger, David C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 28 - 37
  • [37] Comparison study of image quality between filtered back projection and iterative reconstruction algorithm for dose reduction in chest CT
    Son, Junyoung
    Lee, Donghoon
    Jeon, Pil-Hyun
    Choi, Sunghoon
    Kim, Hyemi
    Kim, Hee-Joung
    INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [38] Usefulness of Model-Based Iterative Reconstruction in Brain CT as Compared With Hybrid Iterative Reconstruction
    Sekino, Hirofumi
    Ishii, Shiro
    Kuroiwa, Daichi
    Fujimaki, Hideki
    Sugawara, Shigeyasu
    Suenaga, Hiroki
    Hakozaki, Motoharu
    Yamakuni, Ryo
    Watanabe, Hirotake
    Hasegawa, Osamu
    Ito, Hiroshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (04) : 600 - 605
  • [39] The potential for reduced radiation dose from deep learning-based CT image reconstruction A comparison with filtered back projection and hybrid iterative reconstruction using a phantom
    Lee, Ji Eun
    Choi, Seo-Youn
    Hwang, Jeong Ah
    Lim, Sanghyeok
    Lee, Min Hee
    Ha Yi, Boem
    Cha, Jang Gyu
    MEDICINE, 2021, 100 (19) : E25814
  • [40] Detection of Pulmonary Embolism on Computed Tomography Improvement Using a Model-based Iterative Reconstruction Algorithm Compared With Filtered Back Projection and Iterative Reconstruction Algorithms
    Kligerman, Seth
    Lahiji, Kian
    Weihe, Elizabeth
    Lin, Cheng Tin
    Terpenning, Silanath
    Jeudy, Jean
    Frazier, Annie
    Pugatch, Robert
    Galvin, Jeffrey R.
    Mittal, Deepika
    Kothari, Kunal
    White, Charles S.
    JOURNAL OF THORACIC IMAGING, 2015, 30 (01) : 60 - 68