All reflective optical delay line for real-time optical coherence tomography

被引:0
作者
Kao, Chia-Yun [1 ]
Chang, Chao-Ming [1 ]
Hou, Max Ti-Kuang [1 ]
Hsu, I-Jen [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Phys, Chungli 32023, Taiwan
来源
PHOTONICS NORTH 2006, PTS 1 AND 2 | 2006年 / 6343卷
关键词
optical coherence tomography; optical delay line; real-time; retro-reflector; fast scanning;
D O I
10.1117/12.706306
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
One of the most interested aspects in the development of optical coherence tomography (OCT) is to construct a stable and easy fabricated optical delay line that can perform real-time imaging for clinical applications. There are many methods that have been used for fast scanning in OCT. However, most of the configurations are difficult to construct or variational intensity loss exists during the scanning because of the walk-off of different wavelength components and different tilted angle of the scanner. We proposed and constructed an optical delay line with all reflective components that is compact, easy to fabricate and can avoid the intensity loss during the scanning. The optical delay line was constructed of a retro-reflector fabricated with two right-angled prisms assembled on an aluminum jig, a reflection mirror and a galvoscanner. The size of the optical delay line is within 2 cm x 2 cm and the system can provide a scanning rate in the kilohertz range. The achieved imaging depth is 3.3 mm when the vibration angle of the scanning mirror is +/- 9 degrees. This system can perform a real-time scanning and thus is supposed suitable for clinical applications.
引用
收藏
页数:8
相关论文
共 15 条
[1]   Rotary mirror array for high-speed optical coherence tomography [J].
Chen, NG ;
Zhu, Q .
OPTICS LETTERS, 2002, 27 (08) :607-609
[2]   High-speed path-length scanning with a multiple-pass cavity delay line [J].
Hsiung, PL ;
Li, XD ;
Chudoba, C ;
Hartl, I ;
Ko, TH ;
Fujimoto, JG .
APPLIED OPTICS, 2003, 42 (04) :640-648
[3]   Time-independent dispersion compensation in rapid-scanning optical coherence tomography [J].
Hsu, IJ ;
Lu, CW ;
Tsai, MT ;
Yang, CC .
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 :187-195
[4]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[5]   Ultrahigh-resolution optical coherence tomography with a fiber laser source at 1 μm [J].
Lim, H ;
Jiang, Y ;
Wang, YM ;
Huang, YC ;
Chen, ZP ;
Wise, FW .
OPTICS LETTERS, 2005, 30 (10) :1171-1173
[6]   Rapid scanning all-reflective optical delay line for real-time optical coherence tomography: erratum (vol 30, pg 80, 2005) [J].
Liu, XM ;
Cobb, MJ ;
Li, XD .
OPTICS LETTERS, 2005, 30 (13) :1744-1744
[7]   Rapid scanning all-reflective optical delay line for real-time optical coherence tomography [J].
Liu, XM ;
Cobb, MJ ;
Li, XD .
OPTICS LETTERS, 2004, 29 (01) :80-82
[8]   Real-time, ultrahigh-resolution, optical coherence tomography with an all-fiber, femtosecond fiber laser continuum at 1.5 μm [J].
Nishizawa, N ;
Chen, Y ;
Hsiung, P ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 2004, 29 (24) :2846-2848
[9]   Fast-Fourier-domain delay line for in vivo optical coherence tomography with a polygonal scanner [J].
Oldenburg, AL ;
Reynolds, JJ ;
Marks, DL ;
Boppart, SA .
APPLIED OPTICS, 2003, 42 (22) :4606-4611
[10]   Submicrometer axial resolution optical coherence tomography [J].
Povazay, B ;
Bizheva, K ;
Unterhuber, A ;
Hermann, B ;
Sattmann, H ;
Fercher, AF ;
Drexler, W ;
Apolonski, A ;
Wadsworth, WJ ;
Knight, JC ;
Russell, PSJ ;
Vetterlein, M ;
Scherzer, E .
OPTICS LETTERS, 2002, 27 (20) :1800-1802