Research on Efficiency test of Mixed-flow Pump with Different Blade Angles

被引:0
作者
Sun, Shasha [1 ]
Xu, Bingfeng [1 ]
机构
[1] Kunming Univ Sci & Technol, Coll Civil Engn & Architecture, Kunming, Peoples R China
来源
PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4 | 2013年 / 405-408卷
关键词
mixed-flow pump; blade; efficiency test;
D O I
10.4028/www.scientific.net/AMM.405-408.3248
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Mixed-flow pump is one of the most widely used general machinery, it is necessary to study the efficiency of the mixed-flow pump. In this paper, we have made a test on a mixed-flow pump model. After testing we got the conclusion that the mixed flow pump efficiency analysis of experiments in 6 different blade angle of operation, through the analysis of the status, to this model the suitable angle is -4 degrees.